STATISTICAL CONSIDERATIONS FOR THE DIRECT INTRODUCTION OF PARTICULATE SAMPLES FOR PLASMA EMISSION AND PLASMA SOURCE-MASS SPECTROMETRY

被引:12
作者
DESILVA, KN
GUEVREMONT, R
机构
[1] NATL RES COUNCIL CANADA,DIV CHEM,MONTREAL RD,OTTAWA K1A 0R6,ONTARIO,CANADA
[2] GEOL SURVEY CANADA,DIV MINERAL RESOURCES,OTTAWA K1A 0E8,ONTARIO,CANADA
关键词
D O I
10.1016/0584-8547(90)80148-C
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The statistical relationships for measurement uncertainties due to the discrete nature of particles in the direct analysis of powder samples with plasma sources are derived. Although the principles can be applied to direct analysis of particulates in general, the emphasis is placed on the introduction of powder samples by fluidized-bed and slurry nebulization methods. Uncertainties unique to the direct analysis of powders can be attributed to two main factors; random variation of the number of particles used for measurement, and homogeneity of the powder. Relationships for the compound uncertainty due to both these effects were derived applying Poisson and binomial distributions for binary mixtures. The compound variance is shown to be equal to the product of the average total number of panicles used for the measurement, and the fraction of particles containing the analyte in the bulk mixture. © 1990.
引用
收藏
页码:933 / 939
页数:7
相关论文
共 34 条
[21]   SLURRY ATOMIZATION DIRECT ATOMIC SPECTROCHEMICAL ANALYSIS OF ANIMAL TISSUE [J].
MOHAMED, N ;
FRY, RC .
ANALYTICAL CHEMISTRY, 1981, 53 (03) :450-455
[22]   DIRECT POWDER INJECTION OF NBS COAL FLY-ASH IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY WITH RAPID SCANNING SPECTROMETRIC DETECTION [J].
NG, KC ;
ZEREZGHI, M ;
CARUSO, JA .
ANALYTICAL CHEMISTRY, 1984, 56 (03) :417-421
[23]   INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION ANALYTICAL SPECTROSCOPY - TANTALUM FILAMENT VAPORIZATION OF MICROLITER SAMPLES [J].
NIXON, DE ;
FASSEL, VA ;
KNISELEY, RN .
ANALYTICAL CHEMISTRY, 1974, 46 (02) :210-213
[24]   DIRECT ANALYSIS OF SOLID SAMPLE WITH ULTRAFINE PARTICLE GENERATION INDUCTIVELY COUPLED PLASMA EMISSION-SPECTROSCOPY [J].
ONO, A ;
SAEKI, M ;
CHIBA, K .
APPLIED SPECTROSCOPY, 1987, 41 (06) :970-976
[25]   SELECTIVE VOLATILIZATION OF TRACE-METALS FROM REFRACTORY SOLIDS INTO AN INDUCTIVELY COUPLED PLASMA [J].
PAGE, AG ;
GODBOLE, SV ;
MADRASWALA, KH ;
KULKARNI, MJ ;
MALLAPURKAR, VS ;
JOSHI, BD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (04) :551-557
[26]   THE INTRODUCTION OF POWDERED SOLID SAMPLES AS AEROSOLS INTO THE INDUCTIVELY COUPLED PLASMA [J].
PFANNERSTILL, PE ;
CARUSO, JA ;
WILLEKE, K .
APPLIED SPECTROSCOPY, 1989, 43 (04) :626-633
[27]   CHARACTERISTICS OF NEBULIZED SUSPENSIONS OF REFRACTORY OXIDE POWDERS USED FOR THE PRODUCTION OF CERAMICS AND THEIR EVAPORATION BEHAVIOR IN AN INDUCTIVELY COUPLED PLASMA [J].
RAEYMAEKERS, B ;
GRAULE, T ;
BROEKAERT, JAC ;
ADAMS, F ;
TSCHOPEL, P .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (08) :923-940
[28]   DIRECT SAMPLE INSERTION DEVICE FOR INDUCTIVELY COUPLED PLASMA EMISSION SPECTROMETRY [J].
SALIN, ED ;
HORLICK, G .
ANALYTICAL CHEMISTRY, 1979, 51 (13) :2284-2286
[30]   LASER ABLATION FOR THE INTRODUCTION OF SOLID SAMPLES INTO AN INDUCTIVELY COUPLED PLASMA FOR ATOMIC-EMISSION SPECTROMETRY [J].
THOMPSON, M ;
GOULTER, JE ;
SIEPER, F .
ANALYST, 1981, 106 (1258) :32-39