SIMULTANEOUS USAGE OF HOMOLOGOUS POINTS, LINES, AND PLANES FOR OPTIMAL, 3-D, LINEAR REGISTRATION OF MULTIMODALITY IMAGING DATA

被引:49
作者
MEYER, CR [1 ]
LEICHTMAN, GS [1 ]
BRUNBERG, JA [1 ]
WAHL, RL [1 ]
QUINT, LE [1 ]
机构
[1] UNIV MICHIGAN,DEPT INTERNAL MED,DIV NUCL MED,ANN ARBOR,MI 48109
关键词
D O I
10.1109/42.370397
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We have extended point-based registration to include simultaneous registration of points, lines, and planes, to permit accurate and easily implemented three-dimensional (3-D) registration of multimodal data sets for fusion of clinical anatomic and functional imaging modalities, Constructive geometry is used to define user-identified features where each feature's role in the reconstruction is weighted based on its relative statistical quality, i.e., variance, The algorithm employs singular value decomposition (SVD) and optimization techniques to find the minimum weighted least mean square error (LMSE) affine solution, The new method is generally more accurate due to the availability of more features to register. Notably the error surface contains only one minimum, Different subclasses of affine solutions can be obtained based on appropriateness and sufficiency of the number and type of input features, Preliminary results indicate that this method is useful in multimodal diagnostic image fusion.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 19 条
[1]  
ALPERT NM, 1990, J NUCL MED, V31, P1717
[2]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[3]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[4]  
BEVINGTON PR, 1969, DATA REDUCTION ERROR, P114
[6]   ANATOMICAL-FUNCTIONAL CORRELATION USING AN ADJUSTABLE MRI-BASED REGION OF INTEREST ATLAS WITH POSITRON EMISSION TOMOGRAPHY [J].
EVANS, AC ;
BEIL, C ;
MARRETT, S ;
THOMPSON, CJ ;
HAKIM, A .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (04) :513-530
[7]  
GUEZIEC A, 1992, P EUR C COMPUT VISIO, P620
[8]   REGISTRATION OF 3-DIMENSIONAL MR AND PET IMAGES OF THE HUMAN BRAIN WITHOUT MARKERS [J].
KAPOULEAS, I ;
ALAVI, A ;
ALVES, WM ;
GUR, RE ;
WEISS, DW .
RADIOLOGY, 1991, 181 (03) :731-739
[9]   INTEGRATION OF MULTIMODALITY IMAGING DATA FOR RADIOTHERAPY TREATMENT PLANNING [J].
KESSLER, ML ;
PITLUCK, S ;
PETTI, P ;
CASTRO, JR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (06) :1653-1667
[10]   RETROSPECTIVE GEOMETRIC CORRELATION OF MR, CT, AND PET IMAGES [J].
LEVIN, DN ;
PELIZZARI, CA ;
CHEN, GTY ;
CHEN, CT ;
COOPER, MD .
RADIOLOGY, 1988, 169 (03) :817-823