Toward the ultimate metal microelectrode

被引:84
作者
Loeb, GE [1 ]
Peck, RA [1 ]
Martyniuk, J [1 ]
机构
[1] PI MED CORP,PORTLAND,OR
关键词
electrophysiology; parylene; iridium;
D O I
10.1016/0165-0270(95)00107-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of metal microelectrodes for stimulating and recording neuronal action potentials depends on precise control of their geometrical, electrical and mechanical properties. We describe a combination of materials whose properties approach fundamental physical limitations on achievable performance and reproducible fabrication techniques that provide probes with very small dimensions. Pure iridium wire is electrolytically sharpened, vapor-coated with Parylene-C insulation and the tip exposed using an automatically steerable UV laser. Electrochemical activation of the iridium increases the capacitance of the metal-electrolyte interface so that the overall impedance in the relevant frequency band (100-10 000 Hz) is dominated by the access resistance of the surrounding tissues.
引用
收藏
页码:175 / 183
页数:9
相关论文
共 30 条
[1]  
ABE T, 1987, JPN J MED ELECTRON B, V25, P299
[2]   CHRONIC ANIMAL TESTING OF NEW CARDIAC PACING ELECTRODES [J].
ADLER, S ;
SPEHR, P ;
ALLEN, J ;
BLOCK, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (12) :1896-1900
[3]  
ASHFORD JW, 1985, J NEUROSCI METH, V14, P247, DOI 10.1016/0165-0270(85)90086-X
[4]   CRITERIA FOR SELECTING ELECTRODES FOR ELECTRICAL-STIMULATION - THEORETICAL AND PRACTICAL CONSIDERATIONS [J].
BRUMMER, SB ;
ROBBLEE, LS ;
HAMBRECHT, FT .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1983, 405 (JUN) :159-171
[5]   A VOLTAMMETRIC INVESTIGATION OF THE CHARGE STORAGE REACTIONS OF HYDROUS IRIDIUM OXIDE LAYERS [J].
BURKE, LD ;
WHELAN, DP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 162 (1-2) :121-141
[6]   COMPARISON OF IMPEDANCE AT THE MICROELECTRODE SALINE AND MICROELECTRODE CULTURE-MEDIUM INTERFACE [J].
CARTER, SJ ;
LINKER, CJ ;
TURKLEHUSLIG, T ;
HOWARD, LL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (11) :1123-1129
[7]   A SIMPLE DEVICE FOR THE RELIABLE PRODUCTION OF VARNISH-INSULATED, HIGH-IMPEDANCE TUNGSTEN MICROELECTRODES [J].
CIANCONE, MT ;
REBEC, GV .
JOURNAL OF NEUROSCIENCE METHODS, 1989, 27 (01) :77-79
[8]  
DELBUFALO AGA, 1993, PACE, V16, P1240
[9]   THE AC RESPONSE OF IRIDIUM OXIDE-FILMS [J].
GLARUM, SH ;
MARSHALL, JH .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1980, 127 (07) :1467-1474
[10]  
GOLDSTEIN SR, 1973, IEEE T BIO-MED ENG, VBM20, P260, DOI 10.1109/TBME.1973.324190