COMPARISON OF PEPTIDE ANALYSIS RESULTS FOR HORSE, BOVINE AND DOG CYTOCHROME-C USING CAPILLARY ELECTROPHORESIS MASS-SPECTROMETRY WITH UNTREATED CAPILLARY COLUMN AND BASIC BUFFER CONDITION

被引:25
作者
TAKADA, Y
NAKAYAMA, K
YOSHIDA, M
SAKAIRI, M
机构
[1] Central Research Laboratory, Hitachi Ltd, Kokubunji
关键词
D O I
10.1002/rcm.1290080906
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Peptide analysis of cytochrome c using capillary electrophoresis/mass spectrometry was demonstrated to be a rapid, sensitive and useful technique for providing information concerning the location of variation. We analyzed tryptic digests of horse, bovine and dog cytochrome c, and compared the peptide analysis results for information concerning amino acid sequences in proteins. The differences in amino acid sequence were confirmed by taking into consideration that all the other fragments are identical in each map. The use of an untreated capillary column with basic buffer condition (water + acetonitrile + (20 g/L) ammonium carbonate (70/20/10), pH 9.2) had a reproducibility of migration times to within about 2%.
引用
收藏
页码:695 / 697
页数:3
相关论文
共 8 条
[1]   ELECTROSPRAY IONIZATION MASS-SPECTROMETRIC PEPTIDE-MAPPING - A RAPID, SENSITIVE TECHNIQUE FOR PROTEIN-STRUCTURE ANALYSIS [J].
CHOWDHURY, SK ;
KATTA, V ;
CHAIT, BT .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1990, 167 (02) :686-692
[2]   LC/MS AND LC/MS/MS DETERMINATION OF PROTEIN TRYPTIC DIGESTS [J].
HUANG, EC ;
HENION, JD .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1990, 1 (02) :158-165
[3]  
KUHR WG, 1990, ANAL CHEM, V62, pR403, DOI 10.1021/ac00211a022
[4]   HIGH-PERFORMANCE ZONE ELECTROPHORESIS [J].
MIKKERS, FEP ;
EVERAERTS, FM ;
VERHEGGEN, TPEM .
JOURNAL OF CHROMATOGRAPHY, 1979, 169 (FEB) :11-20
[5]   OPTIMIZATION OF CAPILLARY ZONE ELECTROPHORESIS ELECTROSPRAY IONIZATION PARAMETERS FOR THE MASS-SPECTROMETRY AND TANDEM MASS-SPECTROMETRY ANALYSIS OF PEPTIDES [J].
MOSELEY, MA ;
JORGENSON, JW ;
SHABANOWITZ, J ;
HUNT, DF ;
TOMER, KB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) :289-300
[6]   IMPROVED ELECTROSPRAY IONIZATION INTERFACE FOR CAPILLARY ZONE ELECTROPHORESIS - MASS-SPECTROMETRY [J].
SMITH, RD ;
BARINAGA, CJ ;
UDSETH, HR .
ANALYTICAL CHEMISTRY, 1988, 60 (18) :1948-1952
[7]  
TAKADA Y, 1993, 4TH P C SOC CHROM SC, P146
[8]   SHEATHLESS CAPILLARY ELECTROPHORESIS ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY USING 10 MU-M ID CAPILLARIES - ANALYSES OF TRYPTIC DIGESTS OF CYTOCHROME-C [J].
WAHL, JH ;
GALE, DC ;
SMITH, RD .
JOURNAL OF CHROMATOGRAPHY A, 1994, 659 (01) :217-222