APPLICATION AND AUTOMATION OF FLOW-INJECTION ANALYSIS (FIA) USING FAST RESPONDING ENZYME GLASS ELECTRODES TO DETECT PENICILLIN IN FERMENTATION BROTH AND UREA IN HUMAN SERUM

被引:6
作者
MEIER, H
LANTREIBECQ, F
TRANMINH, C
机构
[1] Laboratoire de Biotechnologie, Ecole des Mines de Saint-Etienne
来源
JOURNAL OF AUTOMATIC CHEMISTRY | 1992年 / 14卷 / 04期
关键词
D O I
10.1155/S1463924692000269
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An enzyme immobilization technique has been developed to determine the concentration of biological compounds. This technique has been applied to penicillinase and urease, which are cross-linked as very fine films directly onto the sensitive ends of pH glass electrodes, thereby dispensing with the need of an on-line enzyme reactor. The biosensor is incorporated in an FIA system within a magnetically stirred detection cell. Penicillin-V in fermentation broth and urea in human serum samples were detected and the results were compared with HPLC and spectrophotometric methods. On-line measurement is achieved through the automation of this FIA system.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 18 条
[1]   MONITORING OF SUBSTRATES AND PRODUCTS DURING FED-BATCH PENICILLIN FERMENTATIONS ON COMPLEX MEDIA [J].
CHRISTENSEN, LH ;
NIELSEN, J ;
VILLADSEN, J .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :123-136
[2]   IMPROVED PENICILLIN SELECTIVE ENZYME ELECTRODE [J].
CULLEN, LF ;
RUSLING, JF ;
SCHLEIFER, A ;
PAPARIELLO, GJ .
ANALYTICAL CHEMISTRY, 1974, 46 (13) :1955-1961
[3]   FLOW-INJECTION DETERMINATION OF PENICILLINS USING IMMOBILIZED PENICILLINASE IN A SINGLE BEAD STRING REACTOR [J].
GNANASEKARAN, R ;
MOTTOLA, HA .
ANALYTICAL CHEMISTRY, 1985, 57 (06) :1005-1009
[4]   DETERMINATION OF L-ALANINE IN A FLOW-INJECTION SYSTEM WITH AN IMMOBILIZED ENZYME REACTOR [J].
KIBA, N ;
TAGAMI, H ;
FURUSAWA, M .
ANALYTICA CHIMICA ACTA, 1990, 239 (02) :307-310
[5]   DETERMINATION OF ORGANOPHOSPHOROUS AND CARBAMATE INSECTICIDES BY FLOW-INJECTION ANALYSIS [J].
KUMARAN, S ;
TRANMINH, C .
ANALYTICAL BIOCHEMISTRY, 1992, 200 (01) :187-194
[6]   IMMOBILIZATION OF THIN ENZYME MEMBRANES TO CONSTRUCT GLASS ENZYME ELECTRODES [J].
KUMARAN, S ;
MEIER, H ;
DANNA, AM ;
TRANMINH, C .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :1914-1918
[7]   DETERMINATION OF PENICILLIN-V IN STANDARD SOLUTION AND IN FERMENTATION BROTH BY FLOW-INJECTION ANALYSIS USING FAST-RESPONDING ENZYME GLASS ELECTRODES IN DIFFERENT DETECTION CELLS [J].
MEIER, H ;
TRANMINH, C .
ANALYTICA CHIMICA ACTA, 1992, 264 (01) :13-22
[8]   RAPID MEASUREMENT OF PENICILLIN CONTAINED IN COMPLEX MEDIA USING ENZYME-LOADED GLASS ELECTRODES [J].
MEIER, H ;
KUMARAN, S ;
DANNA, AM ;
TRANMINH, C .
ANALYTICA CHIMICA ACTA, 1991, 249 (02) :405-411
[9]   FLOW-INJECTION ANALYSIS OF SERUM UREA USING UREASE COVALENTLY IMMOBILIZED ON 2-FLUORO-1-METHYLPYRIDINIUM SALT-ACTIVATED FRACTOGEL AND FLUORESCENCE DETECTION [J].
NARINESINGH, D ;
MUNGAL, R ;
NGO, TT .
ANALYTICAL BIOCHEMISTRY, 1990, 188 (02) :325-329
[10]  
NEUMANN U, 1977, 16 NORD K KLIN KEM K