A SILICON DIODE IN A THIMBLE-TYPE MOUNT FOR MEASUREMENT OF DIAGNOSTIC-X-RAY SPECTRA

被引:9
作者
AOKI, K
KOYAMA, M
机构
[1] Dept. of Radiol., Komazawa Junior Coll., Tokyo
关键词
D O I
10.1088/0031-9155/35/11/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A silicon detector which can be used like a thimble chamber has been constructed. The silicon diode chip used here is very small (1.7*1.7*0.1 mm3), and the construction materials of the detector mount are thin and have low atomic numbers. Thus, the characteristic X-rays from the mount give no distortion on the obtained spectra, and the photons incident on the back surface of the silicon chip can be measured. Furthermore, the perturbation of the X-ray field is small. The energy resolution of the detector is 2.0 keV (full width at half maximum) for 59.5 keV photons at room temperature. Bremsstrahlung spectra (60-100 kV, 1-2 mA) have been measured without using a pinhole collimator: the obtained spectra are in good agreement with those obtained with a Ge detector. The spectrum of the radiation in a water phantom irradiated with 90 kV X-rays has also been measured by inserting the detector in the phantom.
引用
收藏
页码:1505 / 1517
页数:13
相关论文
共 20 条
[1]   MEASUREMENT OF DIAGNOSTIC-X-RAY SPECTRA USING A SILICON PHOTODIODE [J].
AOKI, K ;
KOYAMA, M .
MEDICAL PHYSICS, 1989, 16 (04) :529-536
[2]   PHOTOELECTRON ESCAPE FROM A SILICON X-RAY-DETECTOR - MONTE-CARLO STUDY [J].
AOKI, K ;
KOYAMA, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (08) :1051-1063
[3]  
Browne E., 1986, TABLE RADIOACTIVE IS
[4]   MONTE-CARLO SIMULATION STUDIES OF DETECTORS USED IN THE MEASUREMENT OF DIAGNOSTIC-X-RAY SPECTRA [J].
CHEN, CS ;
DOI, K ;
VYBORNY, C ;
CHAN, HP ;
HOLJE, G .
MEDICAL PHYSICS, 1980, 7 (06) :627-635
[5]   MEASUREMENT OF THE SPECTRAL DISTRIBUTION OF SCATTERED 400 KVP X-RAYS IN A WATER PHANTOM [J].
CORMACK, DV ;
GRIFFITH, TJ ;
JOHNS, HE .
BRITISH JOURNAL OF RADIOLOGY, 1957, 30 (351) :129-135
[6]   SPECTRAL DISTRIBUTIONS OF PRIMARY AND SCATTERED 140-KVP X-RAYS [J].
CORMACK, DV ;
BURKE, DG .
RADIOLOGY, 1960, 74 (05) :743-752
[7]   SPECTROMETRY OF LOW-ENERGY GAMMA- AND X-RAYS WITH GE(LI) DETECTORS [J].
DREXLER, G ;
PERZL, F .
NUCLEAR INSTRUMENTS & METHODS, 1967, 48 (02) :332-+
[8]   SPECTRAL FLUENCE OF SCATTERED RADIATION IN A WATER MEDIUM IRRADIATED WITH DIAGNOSTIC X-RAYS [J].
EPP, ER ;
WEISS, H .
RADIATION RESEARCH, 1967, 30 (01) :129-&
[9]  
FEWELL T R, 1977, Medical Physics (Woodbury), V4, P187, DOI 10.1118/1.594364
[10]   SCATTERED RADIATION IN A WATER PHANTOM IRRADIATED BY ROENTGEN PHOTONS BETWEEN 50 AND 250 KEV [J].
HETTINGER, G ;
LIDEN, K .
ACTA RADIOLOGICA, 1960, 53 (01) :73-92