INDIRECT DETECTION IN CAPILLARY ELECTROPHORESIS - COMPARISON BETWEEN INDIRECT UV AND INDIRECT LASER-INDUCED FLUORESCENCE DETECTION FOR THE DETERMINATION OF ISOPRENYL PYROPHOSPHATES

被引:21
作者
ANDERSSON, PE [1 ]
PFEFFER, WD [1 ]
BLOMBERG, LG [1 ]
机构
[1] UNIV STOCKHOLM,ARRHENIUS LABS NAT SCI,DEPT ANALYT CHEM,S-10691 STOCKHOLM,SWEDEN
关键词
D O I
10.1016/0021-9673(95)00019-J
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Three different detection modes were compared for the determination of isoprenyl pyrophosphates by capillary electrophoresis, viz., direct UV, indirect UV and indirect laser-induced fluorescence (ILIF). The composition of the background electrolyte was varied accordingly. On the basis of separation efficiency (N = 600 000) and limit of detection (ca. 0.5 mu M), the ILIF method gave the best results. Separation was complete in less than 6 min.
引用
收藏
页码:323 / 330
页数:8
相关论文
共 42 条
[1]   FLUORESCENCE DETECTION IN CAPILLARY ELECTROPHORESIS [J].
AMANKWA, LN ;
ALBIN, M ;
KUHR, WG .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1992, 11 (03) :114-120
[2]   CAPILLARY ELECTROPHORESIS OF ORGANIC AND INORGANIC CATIONS WITH INDIRECT UV DETECTION [J].
BECK, W ;
ENGELHARDT, H .
CHROMATOGRAPHIA, 1992, 33 (7-8) :313-316
[3]   DETERMINATION OF ISOPENTENYL DIPHOSPHATE AND FARNESYL DIPHOSPHATE IN TISSUE SAMPLES WITH A COMMENT ON SECONDARY REGULATION OF POLYISOPRENOID BIOSYNTHESIS [J].
BRUENGER, E ;
RILLING, HC .
ANALYTICAL BIOCHEMISTRY, 1988, 173 (02) :321-327
[4]   OPTIMIZATION AND EVALUATION OF THE PERFORMANCE OF ARRANGEMENTS FOR UV DETECTION IN HIGH-RESOLUTION SEPARATIONS USING FUSED-SILICA CAPILLARIES [J].
BRUIN, GJM ;
STEGEMAN, G ;
VANASTEN, AC ;
XU, X ;
KRAAK, JC ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1991, 559 (1-2) :163-181
[5]   OPTIMIZATION OF INDIRECT UV DETECTION IN CAPILLARY ZONE ELECTROPHORESIS OF LOW-MOLECULAR-MASS ANIONS [J].
BUCHBERGER, W ;
COUSINS, SM ;
HADDAD, PR .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (08) :313-319
[6]   EVALUATION OF CARRIER ELECTROLYTES FOR CAPILLARY ZONE ELECTROPHORESIS OF LOW-MOLECULAR-MASS ANIONS WITH INDIRECT UV DETECTION [J].
COUSINS, SM ;
HADDAD, PR ;
BUCHBERGER, W .
JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) :397-402
[7]   INFLUENCE OF ANALYTE PLUG WIDTH ON PLATE NUMBER IN CAPILLARY ELECTROPHORESIS [J].
DELINGER, SL ;
DAVIS, JM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1947-1959
[8]   IDENTIFICATION OF GERANYLGERANYL-MODIFIED PROTEINS IN HELA-CELLS [J].
FARNSWORTH, CC ;
GELB, MH ;
GLOMSET, JA .
SCIENCE, 1990, 247 (4940) :320-322
[9]   INDIRECT PHOTOMETRIC DETECTION IN CAPILLARY ZONE ELECTROPHORESIS [J].
FORET, F ;
FANALI, S ;
OSSICINI, L ;
BOCEK, P .
JOURNAL OF CHROMATOGRAPHY, 1989, 470 (01) :299-308
[10]  
FORET F, 1993, CAPILLARY ZONE ELECT, P95