DETERMINATION OF N-METHYLCARBAMATE PESTICIDES IN ENVIRONMENTAL WATER SAMPLES USING AUTOMATED ONLINE TRACE ENRICHMENT WITH EXCHANGEABLE CARTRIDGES AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:27
作者
HIEMSTRA, M [1 ]
DEKOK, A [1 ]
机构
[1] FOD INSPECT SERV,DEPT PESTICIDE ANAL,1824 DW ALKMAAR,NETHERLANDS
关键词
D O I
10.1016/0021-9673(94)89063-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fully automated high-performance liquid chromatographic (HPLC) method was developed for the determination of N-methylcarbamate pesticides and their polar metabolites in various types of water. Two different, commercially available, automated trace enrichment devices (OSP-2 and Prospekt) were investigated as to their performance. Low-carbon C-18-bonded silica (C-18/OH, 40 mu m particle size) was used, as a selective sorbent for solid-phase extraction and preconcentration of N-methylcarbamate pesticides from environmental water samples. PLRP-S (15-25 mu m), a styrene-divinylbenzene polymeric phase, was also evaluated as an alternative to extract N-methylcarbamates. After preconcentrating the N-methylcarbamates on an exchangeable cartridge, the analytes were eluted with the mobile phase gradient and transferred to the reversed-phase HPLC system. Detection was performed via post-column hydrolysis on a solid-phase catalyst (anion exchanger), derivatization of the methylamine formed with o-phthalaldehyde reagent, and fluorescence detection of the isoindole derivative. Both trace enrichment systems showed good quantitative results for the determination of N-methylcarbamates and their metabolites at the 0.1 mu g/l level. The repeatability was excellent with relative standard deviations in the range 2-10%. The method detection limits for surface water were between 30 and 50 ng/l. Sample throughput is about 30 samples per 24 h, unattended. The method proved to be suitable for monitoring N-methylcarbamate pesticides in environmental water samples.
引用
收藏
页码:155 / 166
页数:12
相关论文
共 18 条
  • [1] DETERMINATION OF POLAR POLLUTANTS IN WATER USING AN ONLINE LIQUID-CHROMATOGRAPHIC PRECONCENTRATION SYSTEM
    BROUWER, ER
    LISKA, I
    GEERDINK, RB
    FRINTROP, PCM
    MULDER, WH
    LINGEMAN, H
    BRINKMAN, UAT
    [J]. CHROMATOGRAPHIA, 1991, 32 (9-10) : 445 - 452
  • [2] CHAPUT D, 1986, J ASSOC OFF ANA CHEM, V69, P985
  • [3] COMPARISON OF ONLINE SOLID-PHASE DISK EXTRACTION TO LIQUID-LIQUID-EXTRACTION FOR MONITORING SELECTED PESTICIDES IN ENVIRONMENTAL WATERS
    CHIRON, S
    ALBA, AF
    BARCELO, D
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (12) : 2352 - 2359
  • [4] DEKOK A, 1992, J CHROMATOGR, V623, P265
  • [5] GRAPHITIZED CARBON-BLACK EXTRACTION CARTRIDGES FOR MONITORING POLAR PESTICIDES IN WATER
    DICORCIA, A
    SAMPERI, R
    MARCOMINI, A
    STELLUTO, S
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (07) : 907 - 912
  • [6] DETERMINATION OF PHENOXYACID HERBICIDES IN WATER
    GEERDINK, RB
    GRAUMANS, AMBC
    VIVEEN, J
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 547 (1-2): : 478 - 483
  • [7] LESAGE S, 1989, LC GC-MAG SEP SCI, V7, P268
  • [8] DEVELOPMENT OF AN AUTOMATED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE ONLINE PRECONCENTRATION AND DETERMINATION OF TRACE CONCENTRATIONS OF PESTICIDES IN DRINKING-WATER
    MARVIN, CH
    BRINDLE, ID
    HALL, CD
    CHIBA, M
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 503 (01): : 167 - 176
  • [9] SIMULTANEOUS DETERMINATION OF TRACE CONCENTRATIONS OF BENOMYL, CARBENDAZIM (MBC) AND 9 OTHER PESTICIDES IN WATER USING AN AUTOMATED ONLINE PRECONCENTRATION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD
    MARVIN, CH
    BRINDLE, ID
    SINGH, RP
    HALL, CD
    CHIBA, M
    [J]. JOURNAL OF CHROMATOGRAPHY, 1990, 518 (01): : 242 - 249
  • [10] MARVIN CH, 1990, J CHROMATOGR, V555, P147