ARTIFACTS RELATED TO SAMPLE INTRODUCTION IN CAPILLARY GEL-ELECTROPHORESIS AFFECTING SEPARATION PERFORMANCE AND QUANTITATION

被引:41
作者
GUTTMAN, A [1 ]
SCHWARTZ, HE [1 ]
机构
[1] PALOMAR ANALYT SERV,REDWOOD CITY,CA 94062
关键词
D O I
10.1021/ac00109a056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two injection-related artifacts with capillary gel electrophoresis (CGE) are reported. The first occurs with consecutive injections from the same, low-volume (10-200 mu L), aqueous sample: progressively smaller peak heights are obtained with each injection. This phenomenon is explained in qualitative terms by examining the electrochemical processes occurring during the electrokinetic sample introduction. A simple solution to this problem is to perform an intermediate electrokinetic injection from a water vial prior to the sample injection. This two-step injection procedure results not only in dramatically increased precision (important for quantitative studies) but also in increased sample loading. The second artifact observed in CGE is related to the physical shape of the inlet of the gel-filled capillary: employing an oblique edge capillary results in poor performance, peak distortion, and loss in resolution.
引用
收藏
页码:2279 / 2283
页数:5
相关论文
共 24 条
  • [1] QUANTITATION OF POLYMERASE CHAIN-REACTION PRODUCTS BY CAPILLARY ELECTROPHORESIS USING LASER FLUORESCENCE
    BUTLER, JM
    MCCORD, BR
    JUNG, JM
    WILSON, MR
    BUDOWLE, B
    ALLEN, RO
    [J]. JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 658 (02): : 271 - 280
  • [2] ON-COLUMN SAMPLE CONCENTRATION USING FIELD AMPLIFICATION IN CZE
    CHIEN, RL
    BURGI, DS
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (08) : A489 - A496
  • [3] INFLUENCE OF THE CAPILLARY EDGE ON THE SEPARATION EFFICIENCY IN CAPILLARY ELECTROPHORESIS
    COHEN, N
    GRUSHKA, E
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 684 (02) : 323 - 328
  • [4] INTERNAL STANDARDIZATION TECHNIQUE FOR CAPILLARY ZONE ELECTROPHORESIS
    DOSE, EV
    GUIOCHON, GA
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (11) : 1154 - 1158
  • [5] EXPERIMENTAL AND THEORETICAL-STUDY OF ARTIFACTUAL PEAK SPLITTING IN CAPILLARY ELECTROPHORESIS
    ERMAKOV, SV
    ZHUKOV, MY
    CAPELLI, L
    RIGHETTI, PG
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (22) : 4034 - 4042
  • [6] SPONTANEOUS INJECTION IN MICROCOLUMN SEPARATIONS
    FISHMAN, HA
    AMUDI, NM
    LEE, TT
    SCHELLER, RH
    ZARE, RN
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (14) : 2318 - 2329
  • [7] MICROCOLUMN SAMPLE INJECTION BY SPONTANEOUS FLUID DISPLACEMENT
    FISHMAN, HA
    SCHELLER, RH
    ZARE, RN
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) : 99 - 107
  • [8] ZONE BROADENING DUE TO SAMPLE INJECTION IN CAPILLARY ZONE ELECTROPHORESIS
    GRUSHKA, E
    MCCORMICK, RM
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 471 : 421 - 428
  • [9] PRACTICAL ASPECTS IN CHIRAL SEPARATION OF PHARMACEUTICALS BY CAPILLARY ELECTROPHORESIS .2. QUANTITATIVE SEPARATION OF NAPROXEN ENANTIOMERS
    GUTTMAN, A
    COOKE, N
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 685 (01) : 155 - 159
  • [10] GUTTMAN A, 1994, HDB CAPILLARY ELECTR, P129