MICROCOLUMN SAMPLE INJECTION BY SPONTANEOUS FLUID DISPLACEMENT

被引:29
作者
FISHMAN, HA [1 ]
SCHELLER, RH [1 ]
ZARE, RN [1 ]
机构
[1] STANFORD UNIV,HOWARD HUGHES MED INST,DEPT MOLEC & CELLULAR PHYSIOL,STANFORD,CA 94305
关键词
D O I
10.1016/0021-9673(94)80057-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The withdrawal of a capillary structure from a sample solution causes a droplet to be formed at the end of the capillary. Because of the interfacial pressure difference across the curved surface of the droplet, the droplet is driven into the entrance of the capillary, thereby causing injection of the sample. Assuming negligible sample penetration by diffusive or convective mixing, this injection is intrinsically the smallest possible for a capillary. Moreover, the injection volume can be varied by changing the shape of the capillary structure, specifically the outer diameter of the capillary. This injection method eliminates the need for external pressure differences, applied fields across the capillary, or precise timing, thus offering several advantages over conventional procedures. Studies using capillary electrophoresis as the separation procedure show that approximately 3.5 nl (66 mu m I.D. capillary) sample volumes can be injected by hand with a reproducibility of 5.8 +/- 0.7% R.S.D. Parameters that affect the variability of the injection are discussed.
引用
收藏
页码:99 / 107
页数:9
相关论文
共 23 条
[1]  
[Anonymous], 1878, NEUZEIT 1004, P3
[2]   DROP FORMATION IN A CIRCULAR LIQUID JET [J].
BOGY, DB .
ANNUAL REVIEW OF FLUID MECHANICS, 1979, 11 :207-228
[3]   EFFECT OF SURFACE DYNAMICS ON PROCESS OF DROPLET FORMATION FROM SUPPORTED AND FREE LIQUID CYLINDERS [J].
CARROLL, BJ ;
LUCASSEN, J .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1974, 70 (07) :1228-1239
[4]  
Castagnola M., 1992, CAPILLARY ELECTROPHO, V52, P118
[5]  
DADOO R, 1992, 1992 PITTSB C AN CHE
[6]   EXPERIMENTS ON CAPILLARY INSTABILITY OF A LIQUID JET [J].
DONNELLY, RJ ;
GLABERSON, W .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1966, 290 (1423) :547-+
[7]   PROBLEMS OF QUANTITATIVE INJECTION IN CAPILLARY ZONE ELECTROPHORESIS [J].
DOSE, EV ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :123-128
[8]  
DRAZIN PG, 1981, HYDRODYNAMIC STABILI, P1
[9]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[10]   SPONTANEOUS INJECTION IN MICROCOLUMN SEPARATIONS [J].
FISHMAN, HA ;
AMUDI, NM ;
LEE, TT ;
SCHELLER, RH ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2318-2329