IMPROVED DETECTION LIMITS FOR ELECTROSPRAY-IONIZATION ON A MAGNETIC-SECTOR MASS-SPECTROMETER BY USING AN ARRAY DETECTOR

被引:14
作者
CODY, RB
TAMURA, J
FINCH, JW
MUSSELMAN, BD
机构
[1] JEOL USA, Inc., Peabody, 01960, MA
关键词
D O I
10.1016/1044-0305(94)85033-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Array detection was compared with point detection for solutions of hen egg-white lysozyme, equine myoglobin, and ubiquitin analyzed by electrospray ionization with a magnetic sector mass spectrometer. The detection limits for samples analyzed by using the array detector system were at least 10 times lower than could be achieved by using a point detector on the same mass spectrometer. The minimum detectable quantity of protein corresponded to a signal-to-background ratio of approximately 2:1 for a 500 amol/muL solution of hen egg-white lysozyme. However, the ultimate practical sample concentrations appeared to be in the 10-100 fmol/muL range for the analysis of dilute solutions of relatively pure proteins or simple mixtures.
引用
收藏
页码:194 / 200
页数:7
相关论文
共 35 条
[11]   ELECTROSPRAY IONIZATION-PRINCIPLES AND PRACTICE [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
MASS SPECTROMETRY REVIEWS, 1990, 9 (01) :37-70
[12]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[13]   DESIGN AND PERFORMANCE OF AN ELECTROSPRAY IONIZATION SOURCE FOR A DOUBLY-FOCUSING MAGNETIC-SECTOR MASS-SPECTROMETER [J].
GALLAGHER, RT ;
CHAPMAN, JR ;
MANN, M .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (10) :369-372
[14]   REMEASUREMENT OF ELECTROSPRAYED PROTEINS IN THE TRAPPED ION CELL OF A FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETER [J].
GUAN, ZQ ;
HOFSTADLER, SA ;
LAUDE, DA .
ANALYTICAL CHEMISTRY, 1993, 65 (11) :1588-1593
[15]   HIGH-RESOLUTION ELECTROSPRAY MASS-SPECTRA OF LARGE MOLECULES [J].
HENRY, KD ;
QUINN, JP ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (14) :5447-5449
[16]   FOURIER-TRANSFORM MASS-SPECTROMETRY OF LARGE MOLECULES BY ELECTROSPRAY IONIZATION [J].
HENRY, KD ;
WILLIAMS, ER ;
WANG, BH ;
MCLAFFERTY, FW ;
SHABANOWITZ, J ;
HUNT, DF .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1989, 86 (23) :9075-9078
[17]   DESIGN CONSIDERATIONS, CALIBRATION AND APPLICATIONS OF AN ARRAY DETECTOR FOR A 4-SECTOR TANDEM MASS-SPECTROMETER [J].
HILL, JA ;
BILLER, JE ;
MARTIN, SA ;
BIEMANN, K ;
YOSHIDOME, K ;
SATO, K .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 92 :211-230
[18]   A VARIABLE DISPERSION ARRAY DETECTOR FOR A TANDEM MASS-SPECTROMETER [J].
HILL, JA ;
BILLER, JE ;
BIEMANN, K .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 111 :1-25
[19]  
ISHIHARA M, 1989, RAPID COMMUN MASS SP, V3, P420
[20]   AN ELECTROSPRAY ION-SOURCE FOR MAGNETIC-SECTOR MASS SPECTROMETERS [J].
LARSEN, BS ;
MCEWEN, CN .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (03) :205-211