PHOTOION DETECTION WITH A WIDE DYNAMIC-RANGE USING A QUADRUPOLE MASS-SPECTROMETER FOR NONRESONANT MULTIPHOTON IONIZATION OF SPUTTERED NEUTRALS

被引:7
作者
MARUO, T
HIGASHI, Y
TANAKA, T
HOMMA, Y
机构
[1] NTT Interdisciplinary Research Laboratories, Musashimo
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A | 1993年 / 11卷 / 05期
关键词
D O I
10.1116/1.578615
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A sputtered neutral mass spectrometer using nonresonant multiphoton ionization by an excimer laser has been developed. The composition of this instrument is similar to the dynamic secondary ion mass spectrometer. Depth profiling with a wide dynamic range can easily be performed by the combination of a quadrupole mass spectrometer and pulse-counting ion detection. The mass spectrum of photoionized neutrals of GaAs shows that the dynamic range of detection is more than six orders of magnitude and that the product of ionization efficiency and mass spectrometer transmission is about 2.1 X 10(-3). The detection limit for Zn impurity in GaAs is under 1 ppm at a laser repetition rate of 50 Hz.
引用
收藏
页码:2614 / 2618
页数:5
相关论文
共 9 条
[1]   NONRESONANT MULTIPHOTON IONIZATION AS A SENSITIVE DETECTOR OF SURFACE CONCENTRATIONS AND EVAPORATION RATES [J].
BECKER, CH ;
GILLEN, KT .
APPLIED PHYSICS LETTERS, 1984, 45 (10) :1063-1065
[2]  
Benninghoven A., 1987, SECONDARY ION MASS S
[3]   A HYBRID-RESONANCE IONIZATION AND SECONDARY IONIZATION MASS-SPECTROMETER [J].
DOWNEY, SW ;
HOZACK, RS .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1990, 8 (02) :791-796
[4]   SYNCHROTRON RADIATION PHOTOIONIZATION OF SPUTTERED NEUTRALS [J].
OSHIMA, M ;
MAEYAMA, S ;
KAWAMURA, T ;
MARUO, T ;
NAGAI, K .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 1990, 8 (03) :2570-2575
[5]   SURFACE AND INTERFACE ANALYSIS BY NONRESONANT MULTIPHOTON IONIZATION OF SPUTTERED NEUTRALS [J].
PALLIX, JB ;
GILLEN, KT ;
BECKER, CH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1988, 33 (1-4) :912-917
[6]   SPUTTER-INITIATED RESONANCE IONIZATION SPECTROSCOPY [J].
PARKS, JE ;
SCHMITT, HW ;
HURST, GS ;
FAIRBANK, WM .
THIN SOLID FILMS, 1983, 108 (01) :69-78
[7]  
PELLIN MJ, 1984, SURF SCI, V144, P619, DOI 10.1016/0039-6028(84)90123-7
[8]  
Wilson R.G., 1989, SECONDARY ION MASS S
[9]   THE EFFECT OF THE ANGLE OF INCIDENCE ON SECONDARY ION YIELDS OF OXYGEN-BOMBARDED SOLIDS [J].
WITTMAACK, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 218 (1-3) :307-311