IMPROVEMENT OF HETERODYNE ALIGNMENT TECHNIQUE FOR X-RAY STEPPERS

被引:4
作者
KOGA, K
ITOH, T
KUSUMOTO, S
ARAKI, K
YASUI, J
TAKEUCHI, H
AOKI, S
机构
[1] MATSUSHITA RES INST TOKYO INC,KAWASAKI,KANAGAWA 214,JAPAN
[2] MATSUSHITA ELECT IND CO LTD,MORIGUCHI,OSAKA 570,JAPAN
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B | 1993年 / 11卷 / 06期
关键词
D O I
10.1116/1.586452
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article describes the alignment accuracy of the x-ray stepper that was codeveloped by the SORTEC Corporation and Matsushita Electric Industrial Co., and installed in the Tsukuba Research Laboratory for the SORTEC Corporation [K. Koga et al., J. Vac. Sci. Technol. B 8, 1633 (1990)]. Although the optical heterodyne method used for the stepper has a high position detection sensitivity, this method has the drawback that the alignment accuracy is apt to be influenced by an uncontrollable interference, because it uses a coherent laser light source. The overlay accuracy of the stepper was evaluated and identified the error factor contributing to the total overlay error. It was found that the deterioration of the alignment accuracy resulting from position detection error is caused by subtle deflection in the optical alignment system. In order to solve this problem, the alignment unit of the x-ray stepper has been improved. As a result, an alignment accuracy of less than 24 nm (3sigma) was obtained in a double-exposure experiment with a posiresist. In addition, an alignment accuracy of less than 38 nm (3sigma) was also obtained with SiO2 etched marks.
引用
收藏
页码:2179 / 2182
页数:4
相关论文
共 6 条
[1]   CXRL ALIGNER - AN EXPERIMENTAL X-RAY-LITHOGRAPHY SYSTEM FOR QUARTER-MICRON FEATURE DEVICES [J].
CHEN, G ;
WALLACE, J ;
NACHMAN, R ;
WELLS, G ;
BODOH, D ;
ANDERSON, P ;
REILLY, M ;
CERRINA, F .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1992, 10 (06) :3229-3234
[2]   X-RAY STEPPER EXPOSURE SYSTEM PERFORMANCE AND STATUS [J].
FLAMHOLZ, A ;
RIPPSTEIN, R .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1990, 8 (06) :2002-2007
[3]  
HUGHLETT E, 1991, P SOC PHOTO-OPT INS, V1465, P100
[4]   A VERTICAL STEPPER FOR SYNCHROTRON X-RAY-LITHOGRAPHY [J].
ISHIHARA, S ;
KANAI, M ;
UNE, A ;
SUZUKI, M .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1989, 7 (06) :1652-1656
[5]   EVALUATION OF HETERODYNE ALIGNMENT TECHNIQUE FOR X-RAY STEPPERS [J].
KOGA, K ;
HIGASHIKAWA, I ;
ITOH, T ;
ARAKI, K ;
FUJITA, K ;
YASUI, J ;
AOKI, S .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1992, 10 (06) :3248-3251
[6]   SYNCHROTRON RADIATION STEPPER WITH NEW ALIGNMENT SYSTEM [J].
SATO, F ;
ITO, K ;
MIYATAKE, T ;
YAMAZAKI, K ;
HAMADA, S ;
TOMITA, Y .