EFFECTS OF HEART-RATE ON PHASIC CORONARY BLOOD-FLOW PATTERN AND FLOW RESERVE IN PATIENTS WITH NORMAL CORONARY-ARTERIES - A STUDY WITH AN INTRAVASCULAR DOPPLER CATHETER AND SPECTRAL-ANALYSIS

被引:28
作者
HONGO, M
NAKATSUKA, T
WATANABE, N
TAKENAKA, H
TANAKA, M
KINOSHITA, O
OKUBO, S
SEKIGUCHI, M
机构
[1] First Department of Internal Medicine, Shinshu University School of Medicine, Matsumoto
关键词
D O I
10.1016/0002-8703(94)90661-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To assess the effects of pacing-induced tachycardia on phasic coronary blood flow pattern and flow reserve of left anterior descending artery, we examined 16 patients with chest pain and angiographically normal coronary arteries by using an intravascular Doppler catheter with spectral analysis of the velocity signal. The heart rate was increased from a mean of 68 +/- 11 beats/min during sinus rhythm to 100 beats/min and again to 120 beats/min. Cross-sectional area of the epicardial artery and resting systolic and diastolic coronary blood flows increased progressively, resulting in an elevation of total coronary flow from 142 +/- 54 ml/min during sinus rhythm to 190 +/-: 66 ml/min at 100 beats/min (p < 0.05) and to 219 +/- 69 ml/min at 120 beats/min (p < 0.01). During maximal hyperemia with intracoronary injection of 10 to 12 mg of papaverine, there was an increase in the systolic coronary blood flow with a decrease in the diastolic flow, resulting in no significant change in the total flow. These alterations led to progressive reductions in coronary flow reserve from 3.9 +/- 0.7 during sinus rhythm to 2.9 +/- 0.9 at 100 beats/min (p < 0.01) and to 2.3 +/- 0.3 at 120 beats/min (p < 0.001). Thus careful consideration should be given to the effects of heart rate when phasic coronary blood flow pattern and flow reserve are assessed.
引用
收藏
页码:545 / 551
页数:7
相关论文
共 27 条
[21]   MEASUREMENT OF VOLUMETRIC CORONARY BLOOD-FLOW WITH A DOPPLER CATHETER - VALIDATION IN AN ANIMAL-MODEL [J].
SUDHIR, K ;
HARGRAVE, VK ;
JOHNSON, EL ;
ALDEA, G ;
MORI, H ;
PORTS, TA ;
YOCK, PG .
AMERICAN HEART JOURNAL, 1992, 124 (04) :870-875
[22]   ACCURACY OF 20-MHZ DOPPLER CATHETER CORONARY-ARTERY VELOCIMETRY FOR MEASUREMENT OF CORONARY BLOOD-FLOW VELOCITY [J].
TADAOKA, S ;
KAGIYAMA, M ;
HIRAMATSU, O ;
OGASAWARA, Y ;
TSUJIOKA, K ;
WADA, Y ;
SAWAYAMA, T ;
KAJIYA, F .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1990, 19 (03) :205-213
[23]   APPLICATION OF DIGITAL-TECHNIQUES TO SELECTIVE CORONARY ARTERIOGRAPHY - USE OF MYOCARDIAL CONTRAST APPEARANCE TIME TO MEASURE CORONARY FLOW RESERVE [J].
VOGEL, R ;
LEFREE, M ;
BATES, E ;
ONEILL, W ;
FOSTER, R ;
KIRLIN, P ;
SMITH, D ;
PITT, B .
AMERICAN HEART JOURNAL, 1984, 107 (01) :153-164
[24]   TRANS-LUMINAL, SUBSELECTIVE MEASUREMENT OF CORONARY-ARTERY BLOOD-FLOW VELOCITY AND VASODILATOR RESERVE IN MAN [J].
WILSON, RF ;
LAUGHLIN, DE ;
ACKELL, PH ;
CHILIAN, WM ;
HOLIDA, MD ;
HARTLEY, CJ ;
ARMSTRONG, ML ;
MARCUS, ML ;
WHITE, CW .
CIRCULATION, 1985, 72 (01) :82-92
[25]   INTRACORONARY PAPAVERINE - AN IDEAL CORONARY VASODILATOR FOR STUDIES OF THE CORONARY CIRCULATION IN CONSCIOUS HUMANS [J].
WILSON, RF ;
WHITE, CW .
CIRCULATION, 1986, 73 (03) :444-451
[26]   ASSESSMENT OF THE HUMAN CORONARY CIRCULATION USING A DOPPLER CATHETER [J].
WILSON, RF .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (14) :D44-D56
[27]   VALIDITY OF CATHETER-TIP DOPPLER TECHNIQUE IN ASSESSMENT OF CORONARY FLOW VELOCITY AND APPLICATION OF SPECTRUM ANALYSIS METHOD [J].
YAMAGISHI, M ;
HOTTA, D ;
TAMAI, J ;
NAKATANI, S ;
MIYATAKE, K .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (08) :758-762