ULTRA-HIGH-SPEED DNA-SEQUENCING USING CAPILLARY ELECTROPHORESIS CHIPS

被引:482
作者
WOOLLEY, AT [1 ]
MATHIES, RA [1 ]
机构
[1] UNIV CALIF BERKELEY,DEPT CHEM,BERKELEY,CA 94720
关键词
D O I
10.1021/ac00116a010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
DNA sequencing has been performed on microfabricated capillary electrophoresis chips. DNA separations were achieved in 50 x 8 mu m cross-section channels microfabricated in a 2 in. x 3 in. glass sandwich structure using a denaturng 9% T, 0% C polyacrylamide sieving medium. DNA sequencing fragment ladders were produced and fluorescently labeled using the recently developed energy transfer dye-labeled primers. Sequencing extension fragments were separated to similar to 433 bases in only 10 min using a one-color detection system and an effective separation distance of only 3.5 cm. Using a four-color labeling and detection format, DNA sequencing with 97% accuracy and single-base resolution to similar to 150 bases was achieved in only 540 s. A resolution of greater than 0.5 was obtained out to 200 bases for both the one- and four-color separations. The prospects for enhancing the resolution and sensitivity of these chip separations are discussed. This work establishes the feasibility of high-speed, high-throughput DNA sequencing using capillary array electrophoresis chips.
引用
收藏
页码:3676 / 3680
页数:5
相关论文
共 22 条
[1]   SEPARATION OF FRAGMENTS UP TO 570 BASES IN LENGTH BY USE OF 6-PERCENT T-NON-CROSS-LINKED POLYACRYLAMIDE FOR DNA-SEQUENCING IN CAPILLARY ELECTROPHORESIS [J].
BEST, N ;
ARRIAGA, E ;
CHEN, DY ;
DOVICHI, NJ .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :4063-4067
[2]   HIGH-SPEED PARALLEL SEPARATION OF DNA RESTRICTION FRAGMENTS USING CAPILLARY ARRAY ELECTROPHORESIS [J].
CLARK, SM ;
MATHIES, RA .
ANALYTICAL BIOCHEMISTRY, 1993, 215 (02) :163-170
[3]   HIGH-SPEED SEPARATION OF ANTISENSE OLIGONUCLEOTIDES ON A MICROMACHINED CAPILLARY ELECTROPHORESIS DEVICE [J].
EFFENHAUSER, CS ;
PAULUS, A ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2949-2953
[4]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[5]   MOBILITY OF SINGLE-STRANDED-DNA AS A FUNCTION OF CROSS-LINKER CONCENTRATION IN POLYACRYLAMIDE CAPILLARY GEL-ELECTROPHORESIS [J].
FIGEYS, D ;
DOVICHI, NJ .
JOURNAL OF CHROMATOGRAPHY, 1993, 645 (02) :311-317
[6]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[7]   DNA SEQUENCING USING CAPILLARY ARRAY ELECTROPHORESIS [J].
HUANG, XHC ;
QUESADA, MA ;
MATHIES, RA .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2149-2154
[8]   CAPILLARY ARRAY ELECTROPHORESIS USING LASER-EXCITED CONFOCAL FLUORESCENCE DETECTION [J].
HUANG, XHC ;
QUESADA, MA ;
MATHIES, RA .
ANALYTICAL CHEMISTRY, 1992, 64 (08) :967-972
[9]   LARGE-SCALE AND AUTOMATED DNA-SEQUENCE DETERMINATION [J].
HUNKAPILLER, T ;
KAISER, RJ ;
KOOP, BF ;
HOOD, L .
SCIENCE, 1991, 254 (5028) :59-67
[10]   PRECOLUMN REACTIONS WITH ELECTROPHORETIC ANALYSIS INTEGRATED ON A MICROCHIP [J].
JACOBSON, SC ;
HERGENRODER, R ;
MOORE, AW ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (23) :4127-4132