DETERMINATION OF 3-HYDROXYBUTYRATE IN SERUM BY FLOW-INJECTION ANALYSIS USING A CO-IMMOBILIZED 3-HYDROXYBUTYRATE DEHYDROGENASE NADH OXIDASE REACTOR AND A CHEMILUMINOMETER

被引:6
作者
KIBA, N
KOEMADO, H
INAGAKI, J
FURUSAWA, M
机构
[1] Department of Applied Chemistry and Biotechnology, Faculty of Engineering, Yamanashi University, Kofu
关键词
CHEMILUMINESCENCE; FLOW INJECTION; CO-IMMOBILIZED ENZYMES REACTOR; 3-HYDROXYBUTYRATE;
D O I
10.1016/0003-2670(94)90051-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection system with a co-immobilized enzyme reactor is described for the determination of 3-hydroxybutyrate. 3Hydroxybutyrate dehydrogenase and NADH oxidase were immobilized on aminated poly(vinyl alcohol) beads and packed into a stainless-steel column (5 cm X 4 mm i.d.). Serum was diluted 10-fold with berate buffer (pH 9.4) and ultrafiltered. Filtrate (20 mu l) was injected into the carrier stream. The hydrogen peroxide produced was detected chemiluminometrically via a luminol-hexacyanoferrate(III) reaction. The calibration graph was linear for 2x10(-7) M-5 X 10(-4) M; the detection limit was 8 X 10(-8) M and the sample throughput was 30 h(-1) without carryover.
引用
收藏
页码:129 / 133
页数:5
相关论文
共 15 条
[1]   A SPECTROPHOTOMETRIC, ENZYMATIC ASSAY FOR D-3-HYDROXYBUTYRATE THAT IS NOT DEPENDENT ON HYDRAZINE [J].
BRASHEAR, A ;
COOK, GA .
ANALYTICAL BIOCHEMISTRY, 1983, 131 (02) :478-482
[2]   PERFORMANCE OF THE STOPPED-FLOW TECHNIQUE IN CHEMI-LUMINESCENCE SPECTROMETRY BASED ON DIRECT RATE MEASUREMENTS [J].
GONZALEZROBLEDO, D ;
SILVA, M ;
PEREZBENDITO, D .
ANALYTICA CHIMICA ACTA, 1989, 217 (02) :239-247
[3]   FLOW-INJECTION SYSTEM FOR THE FLUOROMETRIC-DETERMINATION OF FRUCTOSE WITH AN IMMOBILIZED MANNITOL DEHYDROGENASE REACTOR [J].
KIBA, N ;
INOUE, Y ;
FURUSAWA, M .
ANALYTICA CHIMICA ACTA, 1991, 243 (02) :183-186
[4]  
KIBA N, 1994, IN PRESS TALANTA, V41
[5]  
KOCH DD, 1987, CLIN CHEM, V33, P1761
[6]   EQUILIBRIUM CONSTANT OF BETA-HYDROXYBUTYRIC-DEHYDROGENASE SYSTEM [J].
KREBS, HA ;
WILLIAMSON, DH ;
MELLANBY, J .
BIOCHEMICAL JOURNAL, 1962, 82 (01) :96-&
[7]   AMPEROMETRIC BIOSENSOR FOR RAPID MEASUREMENT OF 3-HYDROXYBUTYRATE IN UNDILUTED WHOLE-BLOOD AND PLASMA [J].
MCNEIL, CJ ;
SPOORS, JA ;
COOPER, JM ;
ALBERTI, KGMM ;
MULLEN, WH .
ANALYTICA CHIMICA ACTA, 1990, 237 (01) :99-105
[8]   THERMOSTABLE REDUCED NICOTINAMIDE ADENINE-DINUCLEOTIDE OXIDASE - APPLICATION TO AMPEROMETRIC ENZYME ASSAY [J].
MCNEIL, CJ ;
SPOORS, JA ;
COCCO, D ;
COOPER, JM ;
BANNISTER, JV .
ANALYTICAL CHEMISTRY, 1989, 61 (01) :25-29
[9]   A FLOW-INJECTION ANALYSIS SYSTEM INVOLVING IMMOBILIZED NADH OXIDASE IN COLUMN FORM FOR CLINICAL ANALYSIS [J].
MURACHI, T ;
TOTANI, M ;
IKEMOTO, M ;
TABATA, M .
JOURNAL OF BIOTECHNOLOGY, 1990, 14 (01) :33-41
[10]  
NUWAYHID NF, 1988, CLIN CHEM, V34, P1790