DECREASE OF SOLVENT WATER LOADING IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY BY USING A MEMBRANE SEPARATOR

被引:43
作者
TAO, H
MIYAZAKI, A
机构
[1] National Institute for Resources and Environment, Tsukuba, Ibaraki 305
关键词
INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; MEMBRANE SEPARATOR; SOLVENT WATER LOADING;
D O I
10.1039/ja9951000001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A hollow-fibre polyimide membrane separator was used to decrease the water loading on an inductively coupled plasma (ICP). An aerosol generated by a pneumatic nebulizer, after large droplets had been removed in a spray chamber, was passed through the membrane separator heated at 80 degrees C. Water in the aerosol was evaporated and removed as water vapour from the inside to the outside of the hollow fibres, and consequently only a dry aerosol was introduced into the ICP. The levels of polyatomic ions, such as ArO+ and ClO+, decreased by one and two orders of magnitude, respectively. The CeO+:Ce+ ratio, cerium being one of the strongest oxide-forming elements, could be decreased to 1.1 x 10(-3) under conditions such that the maximum count rate of Ce+ was obtained. The Ba2+:Ba+ ratio obtained with the membrane separator was relatively lower than that obtained with a cooled spray chamber, Ion kinetic energies were also lowered with decreasing water loading.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 22 条
[1]   REDUCTION OF POLYATOMIC ION INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY BY CRYOGENIC DESOLVATION [J].
ALVES, LC ;
WIEDERIN, DR ;
HOUK, RS .
ANALYTICAL CHEMISTRY, 1992, 64 (10) :1164-1169
[2]   EVALUATION OF AN ULTRASONIC NEBULIZER FOR SAMPLE INTRODUCTION IN INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
CASTILLANO, TM ;
VELA, NP ;
CARUSO, JA ;
STORY, WC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (06) :807-811
[3]   REDUCTION OF THE EFFECTS OF CONCOMITANT ELEMENTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY BY ADDING NITROGEN TO THE PLASMA GAS [J].
CRAIG, JM ;
BEAUCHEMIN, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (06) :937-942
[4]   AN IMPROVED INTERFACE FOR INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY (ICP-MS) [J].
DOUGLAS, DJ ;
FRENCH, JB .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (03) :197-204
[5]   RADIATION VERSUS CONDUCTION IN HEATED SPRAY CHAMBER DESOLVATION FOR INDUCTIVELY COUPLED PLASMAS [J].
EASTGATE, AR ;
FRY, RC ;
GOWER, GH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (02) :305-308
[6]   ION KINETIC ENERGIES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY (ICP-MS) [J].
FULFORD, JE ;
DOUGLAS, DJ .
APPLIED SPECTROSCOPY, 1986, 40 (07) :971-974
[7]   LANGMUIR PROBE POTENTIAL MEASUREMENTS IN THE PLASMA AND THEIR CORRELATION WITH MASS-SPECTRAL CHARACTERISTICS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
GRAY, AL ;
HOUK, RS ;
WILLIAMS, JG .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (01) :13-20
[8]   A MEMBRANE INTERFACE FOR AQUEOUS SAMPLE INTRODUCTION INTO INDUCTIVELY COUPLED PLASMAS [J].
GUSTAVSSON, A ;
HIETALA, P .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (10) :1103-1108
[9]   SIMPLEX OPTIMIZATION OF NITROGEN ARGON PLASMAS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY FOR THE REMOVAL OF CHLORIDE-BASED INTERFERENCES [J].
HILL, SJ ;
FORD, MJ ;
EBDON, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (05) :719-725
[10]   ROLE OF AEROSOL WATER-VAPOR LOADING IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
HUTTON, RC ;
EATON, AN .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (06) :595-598