DESIGN OF COMPENSATORS FOR BREAST RADIOTHERAPY USING ELECTRONIC PORTAL IMAGING

被引:61
作者
EVANS, PM
HANSEN, VN
MAYLES, WPM
SWINDELL, W
TORR, M
YARNOLD, JR
机构
[1] INST CANC RES,DEPT RADIOTHERAPY,SUTTON SM2 5PT,SURREY,ENGLAND
[2] ROYAL MARSDEN NHS TRUST,SUTTON SM2 5PT,SURREY,ENGLAND
关键词
BREAST RADIOTHERAPY; MISSING TISSUE AND HETEROGENEITY COMPENSATORS; INTENSITY MODULATED BEAMS; PORTAL IMAGING;
D O I
10.1016/0167-8140(95)01617-P
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A novel method of designing intensity modulated beams (IMBs) to achieve compensation in external beam radiotherapy of the breast, without the need for CT scans, is presented. The design method comprises three parts: (1) an electronic portal image is used to generate a map of radiological thickness; (2) this map is then used to obtain an estimate of the breast and lung outline; (3) a TMR-based dose calculation algorithm is then used to determine the optimum beam profile to achieve the best dose distribution. The dose distributions calculated for IMBs were compared with those calculated for the use of simple wedges. The results for two patients studied indicate that the dose inhomogeneity for IMBs is +/- 5%, compared with a value of +/- 10% for a wedged plan. The uncertainty in radiological thickness measurement corresponds to a dosimetric error of +/- 2%, Other errors associated with outline estimation are typically less than 2%, with a largest value of +5% for one of the patients who had a large and highly asymmetrical breast, The results for the two patients studied suggest that the uncertainties in the method are significantly smaller than the improvement in dose uniformity produced.
引用
收藏
页码:43 / 54
页数:12
相关论文
共 40 条
  • [31] VANDERGIESSEN IPH, 1973, BRIT J RADIOL, V46, P978
  • [32] ACCURACY IN TANGENTIAL BREAST TREATMENT SET-UP - A PORTAL IMAGING STUDY
    VANTIENHOVEN, G
    LANSON, JH
    CRABEELS, D
    HEUKELOM, S
    MIJNHEER, BJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) : 317 - 322
  • [33] CLINICAL DOSIMETRY FOR RADIOTHERAPY TO THE BREAST BASED ON IMAGING WITH THE PROTOTYPE ROYAL-MARSDEN-HOSPITAL CT SIMULATOR
    WEBB, S
    LEACH, MO
    BENTLEY, RE
    MAUREEMOOTOO, K
    YARNOLD, JR
    TOMS, MA
    GARDINER, J
    PARTON, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (07) : 835 - 845
  • [34] QUALITY ASSURANCE IN DAILY TREATMENT PROCEDURE - PATIENT MOVEMENT DURING TANGENTIAL FIELDS TREATMENT
    WESTBROOK, C
    GILDERSLEVE, J
    YARNOLD, J
    [J]. RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) : 299 - 303
  • [35] PORTAL DOSE IMAGES .1. QUANTITATIVE TREATMENT PLAN VERIFICATION
    WONG, JW
    SLESSINGER, ED
    HERMES, RE
    OFFUTT, CJ
    ROY, T
    VANNIER, MW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (06): : 1455 - 1463
  • [36] A TECHNIQUE OF AUTOMATING COMPENSATOR DESIGN FOR LUNG INHOMOGENEITY CORRECTION USING AN ELECTRON PORTAL IMAGING DEVICE
    YIN, FF
    SCHELL, MC
    RUBIN, P
    [J]. MEDICAL PHYSICS, 1994, 21 (11) : 1729 - 1732
  • [37] INPUT/OUTPUT CHARACTERISTICS OF A MATRIX ION-CHAMBER ELECTRONIC PORTAL IMAGING DEVICE
    YIN, FF
    SCHELL, MC
    RUBIN, P
    [J]. MEDICAL PHYSICS, 1994, 21 (09) : 1447 - 1454
  • [38] PORTAL DOSE IMAGES .2. PATIENT DOSE ESTIMATION
    YING, XR
    GEER, LY
    WONG, JW
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (06): : 1465 - 1475
  • [39] A METHOD FOR IMPLEMENTING DYNAMIC PHOTON-BEAM INTENSITY MODULATION USING INDEPENDENT JAWS AND A MULTILEAF COLLIMATOR
    YU, CX
    SYMONS, MJ
    DU, MN
    MARTINEZ, AA
    WONG, JW
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05) : 769 - 787
  • [40] 1993, ICRU50 INT COMM RAD