Mechanical Properties of Blood-Mixed Polymethylmetacrylate in Percutaneous Vertebroplasty

被引:10
作者
Ahn, Dong Ki [1 ]
Lee, Song [1 ]
Choi, Dea Jung [1 ]
Park, Soon Yeol [1 ]
Woo, Dae Gon [2 ]
Kim, Chi Hoon [2 ]
Kim, Han Sung [2 ]
机构
[1] Seoul Sacred Heart Gen Hosp, Dept Orthoped Surg, 40-12 Chungryangri Dong, Seoul 130011, South Korea
[2] Yonsei Univ, Dept Biomed Engn, Wonju, South Korea
关键词
Filler; Bone cement; Vertebroplasty; Osteoporotic verterbral compression fracture;
D O I
10.4184/asj.2009.3.2.45
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: Mechanical study of polymethylmetacrylate (PMMA) mixed with blood as a filler. Purpose: An attempt was made to modify the properties of PMMA to make it more suitable for percutaneous vertebroplasty (PVP). Overview of Literature: The expected mechanical changes by adding a filler into PMMA included decreasing the Young's modulus, polymerization temperature and setting time. These changes in PMMA were considered to be more suitable and adaptable conditions in PVP for an osteoporotic vertebral compression fracture. Methods: Porous PMMA were produced by mixing 2 ml (B2), 4 ml (B4) and 6 ml (B6) of blood as a filler with 20 g of regular PMMA. The mechanical properties were examined and compared with regular PMMA(R) in view of the Young's modulus, polymerization temperature, setting time and optimal passing-time within an injectable viscosity (20-50 N-needed) through a 2.8 mm-diameter cement-filler tube. The porosity was examined using microcomputed tomography. Results: The Young's modulus decreased from 919.5 MPa (R) to 701.0 MPa (B2), 693.5 Mpa (B4), and 545.6 MPa (B6). The polymerization temperature decreased from 74.2. (R) to 59.8. (B2), 54.2. (B4) and 47.5. (B6). The setting time decreased from 1,065 seconds (R) to 624 seconds (B2), 678 seconds (B4), and 606 seconds (B6), and the optimal passing-time decreased from 75.6 seconds (R) to 46.6 seconds (B2), 65.0 seconds (B4), and 79.0 seconds (B6). The porosity increased from 4.2% (R) to 27.6% (B2), 27.5% (B4) and 29.5% (B6). A homogenous microstructure with very fine pores was observed in all blood-mixed PMMAs. Conclusions: Blood is an excellent filler for PMMA. Group B6 showed more suitable mechanical properties, including a lower elastic modulus due to the higher porosity, less heating and retarded optimal passing-time by the serum barrier, which reduced the level of friction between PMMA and a cement-filler tube.
引用
收藏
页码:45 / 52
页数:8
相关论文
共 38 条
[1]
An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1542-1546
[2]
Temperature measurement during polymerization of polymethylmethacrylate cement used for vertebroplasty [J].
Belkoff, SM ;
Molloy, S .
SPINE, 2003, 28 (14) :1555-1559
[3]
The effect of the monomer-to-powder ratio on the material properties of acrylic bone cement [J].
Belkoff, SM ;
Sanders, JC ;
Jasper, LE .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (04) :396-399
[4]
Adjacent vertebral failure after vertebroplasty - A biomechanical investigation [J].
Berlemann, U ;
Ferguson, SJ ;
Nolte, LP ;
Hein, PF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05) :748-752
[5]
Properties of an injectable low modulus PMMA bone cement for osteoporotic bone [J].
Boger, Andreas ;
Bohner, Marc ;
Heini, Paul ;
Verrier, Sophie ;
Schneider, Erich .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 86B (02) :474-482
[6]
Variation of the mechanical properties of PMMA to suit osteoporotic cancellous bone [J].
Boger, Andreas ;
Bisig, Adrian ;
Bohner, Marc ;
Heini, Paul ;
Schneider, Erich .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2008, 19 (09) :1125-1142
[7]
Combined extraforaminal and intradiscal cement leakage following percutaneous vertebroplasty [J].
Chen, Jung-Kuei ;
Lee, Hung-Maan ;
Shih, Jui-Tien ;
Hung, Sheng-Tsai .
SPINE, 2007, 32 (12) :E358-E362
[8]
Cement distribution, volume, and compliance in vertebroplasty - Some answers from an anatomy-based nonlinear finite element study [J].
Chevalier, Yan ;
Pahr, Dieter ;
Charlebois, Mathieu ;
Heini, Paul ;
Schneider, Erich ;
Zysset, Philippe .
SPINE, 2008, 33 (16) :1722-1730
[9]
Antibiotic-Impregnated Cement in Revision Total Knee Arthroplasty A Prospective Cohort Study of One Hundred and Eighty-three Knees [J].
Chiu, Fang-Yao ;
Lin, Chien-Fu Jeff .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (03) :628-633
[10]
Experimental vertebroplasty using osteoconductive granular material [J].
Cunin, G ;
Boissonnet, H ;
Petite, H ;
Blanchat, C ;
Guillemin, G .
SPINE, 2000, 25 (09) :1070-1076