A review of calibration techniques for freehand 3-D ultrasound systems

被引:153
作者
Mercier, L
Lango, T
Lindseth, F
Collins, DL
机构
[1] McGill Univ, Montreal Neurol Inst, Montreal, PQ, Canada
[2] SINTEF, Hlth Res, Trondheim, Norway
关键词
ultrasound probe calibration; 3-D ultrasound; freehand acquisition; navigation;
D O I
10.1016/j.ultrasmedbio.2004.11.015
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Three-dimensional (3-D) ultrasound (US) is an emerging new technology with numerous clinical applications. Ultrasound probe calibration is an obligatory step to build 3-D volumes from 2-D images acquired in a freehand US system. The role of calibration is to find the mathematical transformation that converts the 2-D coordinates of pixels in the US image into 3-D coordinates in the frame of reference of a position sensor attached to the US probe. This article is a comprehensive review of what has been published in the field of US probe calibration for 3-D US. The article covers the topics of tracking technologies, US image acquisition, phantom design, speed of sound issues, feature extraction, least-squares minimization, temporal calibration, calibration evaluation techniques and phantom comparisons. The calibration phantoms and methods have also been classified in tables to give a better overview of the existing methods. (E-mail: laurence@bic.mni.mcgill.ca) (c) 2005 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:449 / 471
页数:23
相关论文
共 112 条
[11]   SPEED OF SOUND IN PURE WATER AS A FUNCTION OF TEMPERATURE [J].
BILANIUK, N ;
WONG, GSK .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1993, 93 (03) :1609-1612
[12]   Systematic distortions in magnetic position digitizers [J].
Birkfellner, W ;
Watzinger, F ;
Wanschitz, F ;
Enislidis, G ;
Kollmann, C ;
Rafolt, D ;
Nowotny, R .
MEDICAL PHYSICS, 1998, 25 (11) :2242-2248
[13]  
Blackall JM, 2000, LECT NOTES COMPUT SC, V1935, P462
[14]   A rapid calibration method for registration and 3D tracking of ultrasound images using spatial localizer [J].
Boctor, EM ;
Jain, A ;
Choti, MA ;
Taylor, RH ;
Fichtinger, G .
MEDICAL IMAGING 2003: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2003, 5035 :521-532
[15]  
BOGGI DG, 2003, THESIS U W ONTARIO L
[16]   Calibration of three-dimensional ultrasound images for image-guided radiation therapy [J].
Bouchet, LG ;
Meeks, SL ;
Goodchild, G ;
Bova, FJ ;
Buatti, JM ;
Friedman, WA .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02) :559-577
[17]  
Brendel B, 2002, Comput Aided Surg, V7, P146, DOI 10.3109/10929080209146025
[18]   STEREOTACTIC HEAD FRAME FOR USE WITH CT BODY SCANNERS [J].
BROWN, RA .
INVESTIGATIVE RADIOLOGY, 1979, 14 (04) :300-304
[20]   Design of a clinical free-hand 3D ultrasound system [J].
Carr, JC ;
Stallkamp, JL ;
Fynes, MM ;
Gee, AH ;
Prager, RW ;
Treece, GM ;
Overton, C ;
Berman, L .
MEDICAL IMAGING 2000: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2000, 3982 :14-25