A review of calibration techniques for freehand 3-D ultrasound systems

被引:153
作者
Mercier, L
Lango, T
Lindseth, F
Collins, DL
机构
[1] McGill Univ, Montreal Neurol Inst, Montreal, PQ, Canada
[2] SINTEF, Hlth Res, Trondheim, Norway
关键词
ultrasound probe calibration; 3-D ultrasound; freehand acquisition; navigation;
D O I
10.1016/j.ultrasmedbio.2004.11.015
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Three-dimensional (3-D) ultrasound (US) is an emerging new technology with numerous clinical applications. Ultrasound probe calibration is an obligatory step to build 3-D volumes from 2-D images acquired in a freehand US system. The role of calibration is to find the mathematical transformation that converts the 2-D coordinates of pixels in the US image into 3-D coordinates in the frame of reference of a position sensor attached to the US probe. This article is a comprehensive review of what has been published in the field of US probe calibration for 3-D US. The article covers the topics of tracking technologies, US image acquisition, phantom design, speed of sound issues, feature extraction, least-squares minimization, temporal calibration, calibration evaluation techniques and phantom comparisons. The calibration phantoms and methods have also been classified in tables to give a better overview of the existing methods. (E-mail: laurence@bic.mni.mcgill.ca) (c) 2005 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:449 / 471
页数:23
相关论文
共 112 条
[21]  
CARRJC, 1996, SURFACE RECONSTRUCTI
[22]  
Chassat F, 1998, LECT NOTES COMPUT SC, V1496, P277, DOI 10.1007/BFb0056211
[23]   COMPUTER-ASSISTED MEDICAL INTERVENTIONS - PASSIVE AND SEMIACTIVE AIDS [J].
CINQUIN, P ;
BAINVILLE, E ;
BARBE, C ;
BITTAR, E ;
BOUCHARD, V ;
BRICAULT, I ;
CHAMPLEBOUX, G ;
CHENIN, M ;
CHEVALIER, L ;
DELNONDEDIEU, Y ;
DESBAT, L ;
DESSENNE, V ;
HAMADEH, A ;
HENRY, D ;
LAIEB, N ;
LAVALLEE, S ;
LEFEBVRE, JM ;
LEITNER, F ;
MENGUY, Y ;
PADIEU, F ;
PERIA, O ;
POYET, A ;
PROMAYON, M ;
ROUAULT, S ;
SAUTOT, P ;
TROCCAZ, J ;
VASSAL, P .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1995, 14 (03) :254-263
[24]   Intraoperative ultrasound for guidance and tissue shift correction in image-guided neurosurgery [J].
Comeau, RM ;
Sadikot, AF ;
Fenster, A ;
Peters, TM .
MEDICAL PHYSICS, 2000, 27 (04) :787-800
[25]   Integrated MR and ultrasound imaging for improved image guidance in neurosurgery [J].
Comeau, RM ;
Fenster, A ;
Peters, TM .
MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 :747-754
[26]   3D reconstruction of prostate from ultrasound images [J].
CrivianuGaita, D ;
Miclea, F ;
Gaspar, A ;
Margineatu, D ;
Holban, S .
INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 1997, 45 (1-2) :43-51
[27]   FAST ALGORITHMS FOR LOW-LEVEL VISION [J].
DERICHE, R .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1990, 12 (01) :78-87
[28]  
DERICHE R, 1987, 1 INT C COMP VIS LON, P501
[29]   3D ULTRASONIC IMAGE FEATURE LOCALIZATION BASED ON MAGNETIC SCANHEAD TRACKING - IN-VITRO CALIBRATION AND VALIDATION [J].
DETMER, PR ;
BASHEIN, G ;
HODGES, T ;
BEACH, KW ;
FILER, EP ;
BURNS, DH ;
STRANDNESS, DE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (09) :923-936
[30]   Automatic fusion of freehand endoscopic brain images to three-dimensional surfaces: Creating stereoscopic panoramas [J].
Dey, D ;
Gobbi, DG ;
Slomka, PJ ;
Surry, KJM ;
Peters, TM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (01) :23-30