Digital method for quantification of circumferential periodontal bone level using cone beam CT

被引:57
作者
Fleiner, Jonathan [1 ]
Hannig, Christian [2 ]
Schulze, Dirk [3 ]
Stricker, Andres [4 ]
Jacobs, Reinhilde [1 ]
机构
[1] Katholieke Univ Leuven, Fac Med, Oral Imaging Ctr, B-3000 Louvain, Belgium
[2] Tech Univ Dresden, Clin Operat Dent, Med Fac Carl Gustav Carus, D-01307 Dresden, Germany
[3] Dent Diagnost Zentrum Breisgau, D-79098 Freiburg, Germany
[4] Ctr Dent Implantol Periodontol & 3D Imaging, D-78462 Constance, Germany
关键词
Periodontal diagnostics; Cone beam CT; Measurement accuracy; Circumferential bone level; IN-VITRO ASSESSMENT; COMPUTED-TOMOGRAPHY; CONVENTIONAL RADIOGRAPHY; INTRAORAL RADIOGRAPHY; DOSIMETRY; DIAGNOSIS; IMAGES; ACCURACY; DEFECTS; DEVICES;
D O I
10.1007/s00784-012-0715-3
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
The objective of this study is to develop a new approach for radiographically measuring circumferential periodontal bone level using cone beam CT (CBCT) data. Accuracy and precision were assessed using direct probe measurements on a human skull as a reference. Digital quantification of circumferential periodontal bone levels was conducted considering bone level measurements, infrabony crater, and furcation detection. For this purpose, a human bony cadaver skull with a restoration free dentition was used, showing periodontal bony defects of teeth 15-17,25-27,35-37,45-47 (FDI classification). Image datasets were acquired using a Promax 3D CBCT device (Planmeca Oy, Helsinki, Finland) at 80 kV and 8 mA, 160 mu m voxel size. Circumferential radiographic measurements between cemento-enamel junction and the alveolar crest for the mesial, central, and distal bone levels on the oral and vestibular sides of the examined teeth were carried out based on a prototype of specifically developed software. The measurements were performed by an expert panel of three independent, calibrated, and blinded observers. Manual probe measurements of the periodontal bone loss served as reference standard. The adopted software allowed the quantification of periodontal bone loss at all examined teeth. Overall deviation between radiographic and manual measurements of the observers ranged between 0.36 and 0.69 mm; hereby, 83 % of all results were < 0.5 mm. Comparing overall accuracy between the ten turns of radiological measurements, accuracy for all observers ranged from 0.29 to 0.46 mm. The present study design showed a 100 % detection of furcation involvement for radiographic evaluation. The adoption of a special measurement procedure in terms of a 3D coordinate system, which is placed through and perpendicular to the long axis of the tooth, allows consistent measurement positions of the mesial, central, and distal bone levels both for the oral and vestibular sides of the alveolar crest. In this way, reliable and reproducible quantification of circumferential periodontal bone loss using CBCT data with standardized resolution of 160 mu m can be performed in all three dimensions. This new approach of radiographically assessing circumferential periodontal bone level using CBCT data shows a first promising attempt of accurate detection of periodontal bony defects. Yet, possible negative impact of further clinical parameters in terms of artifact occurrence will have to be furthermore carefully investigated.
引用
收藏
页码:389 / 396
页数:8
相关论文
共 26 条
[1]
COMPARISON OF PANORAMIC AND INTRAORAL RADIOGRAPHY AND POCKET PROBING FOR THE MEASUREMENT OF THE MARGINAL BONE LEVEL [J].
AKESSON, L ;
HAKANSSON, J ;
ROHLIN, M .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1992, 19 (05) :326-332
[2]
Linear Accuracy of Cone Beam CT Derived 3D Images [J].
Brown, April A. ;
Scarfe, William C. ;
Scheetz, James P. ;
Silveira, Anibal M. ;
Farman, Allan G. .
ANGLE ORTHODONTIST, 2009, 79 (01) :150-157
[3]
Advances in periodontal diagnosis 1. Traditional clinical methods of diagnosis [J].
Eley, BM ;
Cox, SW .
BRITISH DENTAL JOURNAL, 1998, 184 (01) :12-16
[4]
A comparison of 18 different x-ray detectors currently used in dentistry [J].
Farman, AG ;
Farman, TT .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2005, 99 (04) :485-489
[5]
A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine [J].
Hashimoto, K ;
Arai, Y ;
Iwai, K ;
Araki, M ;
Kawashima, S ;
Terakado, M .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2003, 95 (03) :371-377
[6]
Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view [J].
Hirsch, E. ;
Wolf, U. ;
Heinicke, F. ;
Silva, M. A. G. .
DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (05) :268-273
[7]
Horner K., 2011, RAD PROTECTION CONE
[8]
Kasaj A, 2007, Int J Comput Dent, V10, P155
[9]
Limited cone-beam CT and intraoral radiography for the diagnosis of periapical pathology [J].
Lofthag-Hansen, Sara ;
Huumonen, Sisko ;
Grondahl, Kerstin ;
Grondahl, Hans-Goran .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 103 (01) :114-119
[10]
Dosimetry of two extraoral direct digital imaging devices: NewTom cone beam CT and Orthophos Plus DS panoramic unit [J].
Ludlow, JB ;
Davies-Ludlow, LE ;
Brooks, SL .
DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (04) :229-234