Comparison of 64-Slice Multidetector Computed Tomography With Spectral Analysis of Intravascular Ultrasound Backscatter Signals for Characterizations of Noncalcified Coronary Arterial Plaques

被引:49
作者
Choi, Byoung-Joo [1 ]
Kang, Doo-Kyoung [2 ]
Tahk, Seung-Jea [1 ]
Choi, So-Yeon [1 ]
Yoon, Myeong-Ho [1 ]
Lim, Hong-Seok [1 ]
Kang, Soo-Jin [1 ]
Yang, Hyoung-Mo [1 ]
Park, Jin-Sun [1 ]
Zheng, Mingri [1 ]
Hwang, Gyo-Seung [1 ]
Shin, Joon-Han [1 ]
机构
[1] Ajou Univ, Dept Cardiol, Sch Med, Suwon 441749, South Korea
[2] Ajou Univ, Dept Radiol, Sch Med, Suwon 441749, South Korea
关键词
D O I
10.1016/j.amjcard.2008.05.060
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In vivo identification of plaque composition may allow the detection of vulnerable plaques before rupture. However, the clinical relevance of multidetector computed tomography (MDCT) in characterizing coronary plaques is currently a subject of debate. We compared 64-slice MDCT with virtual histology to investigate the potential role of 64-slice MDCT in the differentiation of composition of noncalcified coronary plaques. Fifty-nine consecutive patients (stable/unstable angina 34/21) were enrolled. Mean computed tomographic (CT) density (Hounsfield units) of noncalcified coronary plaques (n = 80) was compared with a relative volume of each plaque component (fibrous, fibrofatty, calcium, and necrotic core) analyzed by virtual histology. Mean heart rate during MDCT was 58 +/- 9 beats/min. There was a negative correlation between mean CT density and the necrotic core (r = -0.539, p <0.001) and a positive correlation between mean CT density and the fibrotic tissue component (r = 0.571, p <0.001). Mean CT density of the plaques with a <10% necrotic core was significantly higher than that of a >= 10% necrotic core (93.1 +/- 37.5 vs 41.3 +/- 26.4 HU, p <0.00 1). However, overlapping of mean CT densities between plaques with a <10% necrotic core and those with a >= 10% necrotic core was found. In conclusion, mean CT density of noncalcified coronary plaques measured by 64-slice MDCT may depend on the relative volumes of the necrotic core and fibrotic component. Sixty-four-slice MDCT may have the potential for determining composition of noncalcified coronary plaques, which needs further studies for clinical application. (C) 2008 Elsevier Inc. All rights reserved. (Am J Cardiol 2008;102:988-993)
引用
收藏
页码:988 / 993
页数:6
相关论文
共 12 条
[1]   Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT [J].
Becker, CR ;
Nikolaou, K ;
Muders, M ;
Babaryka, G ;
Crispin, A ;
Schoepf, UJ ;
Loehrs, U ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2003, 13 (09) :2094-2098
[2]   Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography [J].
Cademartiri, F ;
Mollet, NR ;
Runza, G ;
Bruining, N ;
Hamers, R ;
Somers, P ;
Knaapen, M ;
Verheye, S ;
Midiri, M ;
Krestin, GP ;
de Feyter, PJ .
EUROPEAN RADIOLOGY, 2005, 15 (07) :1426-1431
[3]   Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques - A comparative study with intracoronary ultrasound [J].
Leber, AW ;
Knez, A ;
Becker, A ;
Becker, C ;
von Ziegler, F ;
Nikolaou, K ;
Rist, C ;
Reiser, M ;
White, C ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (07) :1241-1247
[4]   Accuracy of in vivo coronary plaque morphology assessment - A validation study of in vivo virtual histology compared with in vitro histopathology [J].
Nasu, Kenya ;
Tsuchikane, Etsuo ;
Katoh, Osamu ;
Vince, D. Geoffrey ;
Virmani, Renu ;
Surmely, Jean-Francois ;
Murata, Akira ;
Takeda, Yoshihiro ;
Ito, Tatsuya ;
Ehara, Mariko ;
Matsubara, Tetsuo ;
Terashima, Mitsuyasu ;
Suzuki, Takahiko .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (12) :2405-2412
[5]   Advances in cardiac CT imaging: 64-slice scanner [J].
Nikolaou, K ;
Flohr, T ;
Knez, A ;
Rist, C ;
Wintersperger, B ;
Johnson, T ;
Reiser, MF ;
Becker, CR .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2004, 20 (06) :535-540
[6]   INTRAVASCULAR ULTRASOUND IMAGING - INVITRO VALIDATION AND PATHOLOGICAL CORRELATION [J].
NISHIMURA, RA ;
EDWARDS, WD ;
WARNES, CA ;
REEDER, GS ;
HOLMES, DR ;
TAJIK, AJ ;
YOCK, PG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) :145-154
[7]   Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: Comparison to IVUS [J].
Pohle, Karsten ;
Achenbach, Stephan ;
MacNeill, Briain ;
Ropers, Dieter ;
Ferencik, Maros ;
Moselewski, Fabian ;
Hoffmann, Udo ;
Brady, Thomas J. ;
Jang, Ik-Kyung ;
Daniel, Werner G. .
ATHEROSCLEROSIS, 2007, 190 (01) :174-180
[8]   In vivo intravascular ultrasound-derived thin-cap fibroatheroma detection using ultrasound radiofrequency data analysis [J].
Rodriguez-Granillo, GA ;
García-García, HM ;
Mc Fadden, EP ;
Valgimigli, M ;
Aoki, J ;
de Feyter, P ;
Serruys, PW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (11) :2038-2042
[9]   Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography [J].
Schroeder, S ;
Kopp, AF ;
Baumbach, A ;
Meisner, C ;
Kuettner, A ;
Georg, C ;
Ohnesorge, B ;
Herdeg, C ;
Claussen, CD ;
Karsch, KR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (05) :1430-1435
[10]   Accuracy of density measurements within plaques located in artificial coronary arteries by X-ray multislice CT: Results of a phantom study [J].
Schroeder, S ;
Flohr, T ;
Kopp, AF ;
Meisner, C ;
Kuettner, A ;
Herdeg, C ;
Baumbach, A ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :900-906