Advances in cardiac CT imaging: 64-slice scanner

被引:110
作者
Nikolaou, K
Flohr, T
Knez, A
Rist, C
Wintersperger, B
Johnson, T
Reiser, MF
Becker, CR
机构
[1] Univ Munich, Dept Clin Radiol, Univ Hosp Grosshadern, D-81377 Munich, Germany
[2] Siemens Med Solut, Forchheim, Germany
[3] Univ Munich, Dept Internal Med 1, Univ Hosp Grosshadern, D-81377 Munich, Germany
关键词
D O I
10.1007/s10554-004-7015-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Clinical progress by the development of multi-slice CT (MSCT) technology beyond 16 slices can more likely be expected from further improved spatial and temporal resolution rather than from a mere increase in the volume coverage speed. We present an evaluation of a recently introduced 64-slice CT (64SCT) system, which makes use of a periodic motion of the focal spot in the longitudinal direction (z-flying focal spot) to double the number of simultaneously acquired slices. Materials and Methods: A recently introduced 64SCT system (SOMATOM Sensation 64, Siemens Medical Solutions, Forchheim, Germany) is being described and tested in first clinical practice, applying the following parameters: z-flying focal spot technology, 64 x 0.6 mm slices; spatial resolution, 0.4 x 0.4 x 0.4 mm; gantry rotation time, 330 ms; temporal resolution, 83-165 ms. Various phantom studies and first clinically implemented protocols are being described, to evaluate the full spectrum of possible applications for this scanner type, with a focus on cardiac imaging. Results:ECG-gated cardiac scanning with this 64-slice CT system benefits clearly from both the improved temporal resolution and improved spatial resolution. These benefits enable a more reliable assessment of mixed plaques, due to reduced partial-voluming and beam-hardening artefacts caused by calcifications, and holds great promise for the reliable assessment of in-stent stenoses, as stent lumen visibility is clearly improved as compared to earlier MSCT systems. With the increased volume coverage and acquisition speed of the 64SCT system, a comprehensive emergency protocol of the thorax becomes feasible within an acceptable breath-hold time, performing an ECG-gated CT angiography of the complete thoracic vasculature. This protocol enables a detailed assessment of the thoracic aorta, the pulmonary arteries and the coronary arteries in one single examination. Conclusion: 64SCT Cardiac imaging provides an increased spatial resolution with an isotropic voxel size of 0.4 mm and an improved temporal resolution of 83-165 ms. These benefits hold great promise especially for fast-moving organs requiring detailed imaging, such as the heart and coronary arteries.
引用
收藏
页码:535 / 540
页数:6
相关论文
共 10 条
[1]   Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses [J].
Dewey, M ;
Laule, M ;
Krug, L ;
Schnapauff, D ;
Rogalla, P ;
Rutsch, WF ;
Hamm, B ;
Lembcke, A .
INVESTIGATIVE RADIOLOGY, 2004, 39 (04) :223-229
[2]   Computed tomography and magnetic resonance imaging for noninvasive coronary angiography and plaque imaging - Current and potential future concepts [J].
Fayad, ZA ;
Fuster, V ;
Nikolaou, K ;
Becker, C .
CIRCULATION, 2002, 106 (15) :2026-2034
[3]   New technical developments in multislice CT - Part 1: Approaching isotropic resolution with sub-millimeter 16-slice scanning [J].
Flohr, T ;
Stierstorfer, K ;
Bruder, H ;
Simon, J ;
Schaller, S .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (07) :839-845
[4]   New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac Imaging [J].
Flohr, T ;
Bruder, H ;
Stierstorfer, K ;
Simon, J ;
Schaller, S ;
Ohnesorge, B .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (08) :1022-1027
[5]   Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography [J].
Nieman, K ;
Cademartiri, F ;
Lemos, PA ;
Raaijmakers, R ;
Pattynama, PMT ;
de Feyter, PJ .
CIRCULATION, 2002, 106 (16) :2051-2054
[6]   Multidetector-row computed tomography and magnetic resonance imaging of atherosclerotic lesions in human ex vivo coronary arteries [J].
Nikolaou, K ;
Becker, CR ;
Muders, M ;
Babaryka, G ;
Scheidler, J ;
Flohr, T ;
Loehrs, U ;
Reiser, MF ;
Fayad, ZA .
ATHEROSCLEROSIS, 2004, 174 (02) :243-252
[7]  
Nikolaou Konstantin, 2003, Cardiology Clinics, V21, P639, DOI 10.1016/S0733-8651(03)00091-2
[8]   Cardiac imaging by means of electrocardiographically gated multisection spiral CT: Initial experience [J].
Ohnesorge, B ;
Flohr, T ;
Becker, C ;
Kopp, AF ;
Schoepf, UJ ;
Baum, U ;
Knez, A ;
Klingenbeck-Regn, K ;
Reiser, MF .
RADIOLOGY, 2000, 217 (02) :564-571
[9]   Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction [J].
Ropers, D ;
Baum, U ;
Pohle, K ;
Anders, K ;
Ulzheimer, S ;
Ohnesorge, B ;
Schlundt, C ;
Bautz, W ;
Daniel, WG ;
Achenbach, S .
CIRCULATION, 2003, 107 (05) :664-666
[10]  
Wintersperger Bernd J, 2003, Crit Rev Comput Tomogr, V44, P27, DOI 10.1080/10408370390808450