Assessment of Snared-Loop Technique When Standard Retrieval of Inferior Vena Cava Filters Fails

被引:15
作者
Doody, Orla [1 ]
Noe, Geertje [1 ]
Given, Mark F. [1 ]
Foley, Peter T. [1 ]
Lyon, Stuart M. [1 ]
机构
[1] Alfred Hosp, Dept Radiol, Melbourne, Vic 3004, Australia
关键词
Inferior vena cava filters; Retrieval; Snared-loop; GUNTHER-TULIP; DIFFICULT RETRIEVAL; REMOVAL;
D O I
10.1007/s00270-008-9446-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose To identify the success and complications related to a variant technique used to retrieve inferior vena cava filters when simple snare approach has failed. Methods A retrospective review of all Cook Gunther Tulip filters and Cook Celect filters retrieved between July 2006 and February 2008 was performed. During this period, 130 filter retrievals were attempted. In 33 cases, the standard retrieval technique failed. Retrieval was subsequently attempted with our modified retrieval technique. Results The retrieval was successful in 23 cases (mean dwell time, 171.84 days; range, 5-505 days) and unsuccessful in 10 cases (mean dwell time, 162.2 days; range, 94-360 days). Our filter retrievability rates increased from 74.6% with the standard retrieval method to 92.3% when the snared-loop technique was used. Unsuccessful retrieval was due to significant endothelialization (n = 9) and caval penetration by the filter (n = 1). A single complication occurred in the group, in a patient developing pulmonary emboli after attempted retrieval. Conclusion The technique we describe increased the retrievability of the two filters studied. Hook endothelialization is the main factor resulting in failed retrieval and continues to be a limitation with these filters.
引用
收藏
页码:145 / 149
页数:5
相关论文
共 15 条
[1]   Inferior vena cava filter removal after 317-day implantation [J].
Binkert, CA ;
Bansal, A ;
Gates, JD .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (03) :395-398
[2]   Use of rigid bronchoscopic forceps in the difficult retrieval of the Gunther Tulip inferior vena cava filter [J].
Burke, Charles T. ;
Dixon, Robert G. ;
Stavas, Joseph M. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (10) :1319-1323
[3]   Experience with the recovery filter as a retrievable inferior vena cava filter [J].
Grande, WJ ;
Trerotola, SO ;
Reilly, PM ;
Clark, TWI ;
Soulen, MC ;
Patel, A ;
Shlansky-Goldberg, RD ;
Tuite, CM ;
Solomon, JA ;
Mondschein, JI ;
Fitzpatrick, MK ;
Stavropoulos, SW .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (09) :1189-1193
[4]   Difficult retrieval of a recovery IVC filter [J].
Hagspiel, KD ;
Leung, DA ;
Aladdin, M ;
Spinosa, DJ ;
Matsumoto, AH ;
Angle, JF .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 15 (06) :645-647
[5]   Practice patterns and outcomes of retrievable vena cava filters in trauma patients: An AAST multicenter study [J].
Karmy-Jones, Riyad ;
Jurkovich, Gregory J. ;
Velmahos, George C. ;
Burdick, Thomas ;
Spaniolas, Konstantinos ;
Todd, Samuel R. ;
McNally, Michael ;
Jacoby, Robert C. ;
Link, Daniel ;
Janczyk, Randy J. ;
Ivascu, Felicia A. ;
McCann, Michael ;
Obeid, Farouck ;
Hoff, William S. ;
McQuay, Nathaniel, Jr. ;
Tieu, Brandon H. ;
Schreiber, Martin A. ;
Nirula, Ram ;
Brasel, Karen ;
Dunn, Julie A. ;
Gambrell, Debbie ;
Huckfeldt, Roger ;
Harper, Jayna ;
Schaffer, Kathryn B. ;
Tominaga, Gail T. ;
Vinces, Fausto Y. ;
Sperling, David ;
Hoyt, David ;
Coimbra, Raul ;
Rosengart, Mathew R. ;
Forsythe, Raquel ;
Cothren, Clay ;
Moore, Ernest E. ;
Haut, Elliott R. ;
Hayanga, Awori J. ;
Hird, Linda ;
White, Christopher ;
Grossman, Jodi ;
Nagy, Kimberly ;
Livaudais, West ;
Wood, Rhonda ;
Zengerink, Imme ;
Kortbeek, John B. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 62 (01) :17-24
[6]   Retrieval of trapped Gunther tulip inferior vena cava filters: Snare-over-guide wire loop technique [J].
Kuo, William T. ;
Bostaph, Andrew S. ;
Loh, Christopher T. ;
Frisoli, Joan K. ;
Kee, Stephen T. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (11) :1845-1849
[7]   Gunther Tulip retrievable inferior vena caval filters: Indications, efficacy, retrieval, and complications [J].
Looby, S. ;
Given, M. F. ;
Geoghegan, T. ;
McErlean, A. ;
Lee, M. J. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (01) :59-65
[8]   Retrieval of the Gunther tulip and OptEase filters using the Recovery Cone Removal System [J].
Miller, Michael J. ;
Smith, Tony P. ;
Stavas, Joseph M. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (05) :899-902
[9]   Gunther tulip retrievable vena cava filter: Results from the registry of the Canadian Interventional Radiology Association [J].
Millward, SF ;
Oliva, VL ;
Bell, SD ;
Valenti, DA ;
Rasuli, P ;
Asch, M ;
Hadziomerovic, A ;
Kachura, JR .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (09) :1053-1058
[10]   NEW RETRIEVABLE PERCUTANEOUS VENA-CAVA FILTER - EXPERIMENTAL IN-VITRO AND IN-VIVO EVALUATION [J].
NEUERBURG, J ;
GUNTHER, RW ;
RASSMUSSEN, E ;
VORWERK, D ;
TONN, K ;
HANDT, S ;
KUPPER, W ;
HANSEN, JV .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1993, 16 (04) :224-229