Femoral Head Size and Wear of Highly Cross-linked Polyethylene at 5 to 8 Years

被引:118
作者
Lachiewicz, Paul F. [1 ]
Heckman, Daniel S. [2 ]
Soileau, Elizabeth S. [1 ]
Mangla, Jimmi [3 ]
Martell, John M. [3 ]
机构
[1] Chapel Hill Orthoped Surg & Sports Med, Chapel Hill, NC 27514 USA
[2] Univ N Carolina, Dept Orthopaed, Chapel Hill, NC 27514 USA
[3] Univ Chicago, Med Ctr, Sect Orthopaed Surg & Rehabil Med, Chicago, IL 60637 USA
关键词
TOTAL HIP-ARTHROPLASTY; MOLECULAR-WEIGHT POLYETHYLENE; RADIOSTEREOMETRIC ANALYSIS; CLINICAL-PERFORMANCE; ACETABULAR COMPONENT; UNCEMENTED SOCKETS; PENETRATION RATE; 3RD-BODY WEAR; DISLOCATION; REPLACEMENT;
D O I
10.1007/s11999-009-1038-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Wear of highly cross-linked polyethylene is reportedly independent of head size. To confirm that observation we asked in our population whether head size related to wear with one type of electron beam highly cross-linked polyethylene. Of 146 hips implanted, we evaluated complete clinical and radiographic data for 90 patients (102 hips or 70%). The minimum followup was 5 years (mean, 5.7 years; range, 5-8 years). The head size was selected intraoperatively based on the size of the acetabular component and presumed risk of dislocation. Polyethylene wear measurements were performed in one experienced laboratory using the method of Martell et al. There was no hip with pelvic or femoral osteolysis. The median linear wear rate was 0.028 mm/year (mean, 0.04 mm/year), and the median volumetric wear rate was 25.6 mm(3)/year (mean, 80.5 mm(3)/year). Median total volumetric wear was 41.0 mm(3) (mean, 98.5 mm(3)). We found no association between femoral head size and the linear wear rate, but observed an association between larger (36- and 40-mm) head size and volumetric wear rate and total volumetric wear. Although the linear wear rate of polyethylene was not related to femoral head diameter, there was greater volumetric wear (156.6 mm(3)/year) with the 36- and 40-mm heads. Pending long-term studies of large head sizes, we advise caution in using larger femoral heads in young or active patients and in those with a low risk of dislocation. Level of Evidence: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:3290 / 3296
页数:7
相关论文
共 34 条
[1]
Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36-vs 28-mm femoral heads [J].
Bragdon, Charles R. ;
Greene, Meridith E. ;
Freiberg, Andrew A. ;
Harris, William H. ;
Malchau, Henrik .
JOURNAL OF ARTHROPLASTY, 2007, 22 (06) :125-129
[2]
Third-body wear testing of a highly cross-linked acetabular liner - The effect of large femoral head size in the presence of particulate poly (methyl-methacrylate) debris [J].
Bragdon, CR ;
Jasty, M ;
Muratoglu, OK ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2005, 20 (03) :379-385
[3]
Third-body wear of highly cross-linked polyethylene in a hip simulator [J].
Bragdon, CR ;
Jasty, M ;
Muratoglu, OK ;
O'Connor, DO ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2003, 18 (05) :553-561
[4]
Range of motion and stability in total hip arthroplasty with 28-, 32-, 38-, and 44-mm femoral head sizes - An in vitro study [J].
Burroughs, BR ;
Hallstrom, B ;
Golladay, GJ ;
Hoeffel, D ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 2005, 20 (01) :11-19
[5]
Femoral head sizes larger than 32 mm against highly cross-linked polyethylene [J].
Burroughs, BR ;
Rubash, HE ;
Harris, WH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (405) :150-157
[6]
Comparison of cross-linked polyethylene materials for orthopaedic applications [J].
Collier, JP ;
Currier, BH ;
Kennedy, FE ;
Currier, JH ;
Timmins, GS ;
Jackson, SK ;
Brewer, RL .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (414) :289-304
[7]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[8]
The Otto Aufranc Award -: Highly cross-linked polyethylene in Total Hip Arthroplasty -: Randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis [J].
Digas, G ;
Kärrholm, J ;
Thanner, J ;
Malchau, H ;
Herberts, P .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :6-16
[9]
5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets -: Two randomized studies using radiostereometric analysis [J].
Digas, Georgios ;
Karrholm, Johan ;
Thanner, Jonas ;
Herberts, Peter .
ACTA ORTHOPAEDICA, 2007, 78 (06) :746-754
[10]
Clinical performance of a durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years [J].
Dorr, LD ;
Wan, ZN ;
Shahrdar, C ;
Sirianni, L ;
Boutary, M ;
Yun, A .