Guidelines for improving the lower detection limit of ion-selective electrodes: A systematic approach

被引:70
作者
Radu, Aleksandar
Peper, Shane
Bakker, Eric
Diamond, Dermot [1 ]
机构
[1] Dublin City Univ, Adapt Sensors Grp, Natl Ctr Sensor Res, Sch Chem Sci, Dublin 9, Ireland
[2] Pacific NW Natl Lab, Adv Radioanalyt Chem Grp, Phys & Chem Sci Div, Richland, WA 99352 USA
[3] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
low detection limit; zero-current ion fluxes; ion-selective electrode;
D O I
10.1002/elan.200603741
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Zero-current membrane fluxes are the principal source of bias that has prohibited researchers from obtaining true, thermodynamic selectivity coefficients for membrane-based ion-selective electrodes (ISEs). They are also responsible for the mediocre detection limits historically seen with these types of potentiometric sensors. By choosing an experimental protocol that suppresses these fluxes, it becomes possible to obtain unbiased thermodynamic selectivity coefficients that are needed to produce ISEs with greatly improved detection limits. In this work, a Cs+-selective electrode based on calix[6]arene-hexaacetic acid hexaethyl ester (Cs 1) is used to systematically demonstrate how unbiased selectivity coefficients can be obtained, and how they can be used to optimize inner filling solutions for low detection limit measurements. A comparison of biased selectivity methods (e.g., classical separate solution method (SSM), fixed interference method (FIM), matched potential method (MPM)) with the unbiased modified separate solution method (MSSM) found that selectivity coefficients were underestimated in several cases by more than 4 orders of magnitude (logK(CsMg)(pot,MSSM) = - 8.7; log K-Cs,Mg(pot,SSM) = -4.5). The importance of key experimental parameters, including diffusion coefficients and diffusion layer thicknesses in the aqueous and organic phases, on the minimization of ion fluxes and the improvement of lower detection limits is also described. A dramatic reduction of membrane fluxes by the covalent attachment of a Ca2+-selective ionophore to a methyl methacrylate-decyl methacrylate (MMA-DMA) copolymer matrix is also demonstrated. The ionophore-immobilized ISE exhibited no super-Nernstian response and yielded a detection limit of 40 ppt (109 a(Ca) = - 9-0) with an inner filling solution of 1 x 10(-3) M KCl. Finally, a set of guidelines for experimental protocols leading to obtaining unbiased selectivity coefficients and producing ISEs for trace level analyses is given.
引用
收藏
页码:144 / 154
页数:11
相关论文
共 69 条
[31]   Improving the detection limit of anion-selective electrodes: An iodide-selective membrane with a nanomolar detection limit [J].
Malon, A ;
Radu, A ;
Qin, W ;
Qin, Y ;
Ceresa, A ;
Maj-Zurawska, M ;
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2003, 75 (15) :3865-3871
[32]   Potentiometry at trace levels in confined samples: Ion-selective electrodes with subfemtomole detection limits [J].
Malon, Adam ;
Vigassy, Tamas ;
Bakker, Eric ;
Pretsch, Erno .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (25) :8154-8155
[33]   Effect of transmembrane electrolyte diffusion on the detection limit of carrier-based potentiometric ion sensors [J].
Mathison, S ;
Bakker, E .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :303-309
[34]   Determination of complex formation constants of lipophilic neutral ionophores in solvent polymeric membranes with segmented sandwich membranes [J].
Mi, YM ;
Bakker, E .
ANALYTICAL CHEMISTRY, 1999, 71 (23) :5279-5287
[35]   INFLUENCE OF A CLASSICAL CHELATE EFFECT DUE TO A COVALENT LINKAGE OF IONOPHORE SUBUNITS ON THE PERFORMANCE OF CORRESPONDING ION-SELECTIVE ELECTRODES [J].
MORF, WE ;
BLIGGENSDORFER, R ;
SIMON, W .
ANALYTICAL SCIENCES, 1989, 5 (04) :453-458
[36]   LIFE TIME OF NEUTRAL CARRIER BASED ION-SELECTIVE LIQUID-MEMBRANE ELECTRODES [J].
OESCH, U ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1980, 52 (04) :692-700
[37]   Ion-pairing ability, chemical stability, and selectivity behavior of halogenated dodecacarborane cation exchangers in neutral carrier-based ion-selective electrodes [J].
Peper, S ;
Qin, Y ;
Almond, P ;
McKee, M ;
Telting-Diaz, M ;
Albrecht-Schmitt, T ;
Bakker, E .
ANALYTICAL CHEMISTRY, 2003, 75 (09) :2131-2139
[38]   Improved detection limits and sensitivities of potentiometric titrations [J].
Peper, S ;
Ceresa, A ;
Bakker, E ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2001, 73 (15) :3768-3775
[39]   Potentiometric sensor for the measurement of Cd2+ transport in yeast and plants [J].
Plaza, S ;
Szigeti, Z ;
Geisler, M ;
Martinoia, E ;
Aeschlimann, B ;
Günther, D ;
Pretsch, E .
ANALYTICAL BIOCHEMISTRY, 2005, 347 (01) :10-16
[40]   Improving the lower detection limit of potentiometric sensors by covalently binding the ionophore to a polymer backbone [J].
Püntener, M ;
Vigassy, T ;
Baier, E ;
Ceresa, A ;
Pretsch, E .
ANALYTICA CHIMICA ACTA, 2004, 503 (02) :187-194