High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography - Iopromide 370 versus iomeprol 400

被引:74
作者
Cademartiri, F
de Monye, C
Pugliese, F
Mollet, NR
Runza, G
van der Lugt, A
Midiri, M
de Feyter, PJ
Lagalla, R
Krestin, GP
机构
[1] Erasmus MC, Dept Radiol, Thoraxctr, NL-3015 GD Rotterdam, Netherlands
[2] Erasmus MC, Dept Cardiol, Thoraxctr, NL-3015 GD Rotterdam, Netherlands
[3] Univ Palermo, Dept Radiol, Palermo, Italy
关键词
16-row multislice CT; coronary angiography; contrast material; iodine concentration;
D O I
10.1097/01.rli.0000191369.76521.09
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The objective of this study was to compare intracoronary attenuation on 16-row multislice computed tomography (16-MSCT) coronary angiography using 2 contrast materials (CM) with high iodine concentration. Material and Methods: Forty consecutive patients (29 male, 11 female; mean age, 61 +/- 11 years) with suspected coronary artery disease were randomized to 2 groups to receive 100 mL of either iopromide 370 (group 1: Ultravist 370, 370 mg iodine/mL, Schering AG, Berlin, Germany) or iomeprol 400 (group 2: Iomeron 400, 400 mg iodine/mL; Bracco Imaging SpA, Milan, Italy). Both CM were administered at a rate of 4 mL/s. All patients underwent 16-MSCT coronary angiography (Sensation 16; Siemens, Germany) with collimation 16 X 0.75 mm and rotation time 375 ms. The attenuation in Hounsfield units (HU) achieved after each CM was determined at regions of interest (ROIs) placed at the origin of coronary arteries and on the ascending aorta, descending aorta, and pulmonary artery. Differences in mean attenuation in the coronary arteries and on the ascending aorta, descending aorta, and pulmonary artery were evaluated using Student t test. Results: The mean attenuation achieved at each anatomic site was consistently greater after iomeprol 400 than after iopromide 370. At the origin of coronary arteries, the mean attenuation after iomeprol 400 (340 +/- 53 HU) was greater (P < 0.05) than that after iopromide 370 (313 +/- 42 HU). Similar findings were noted for the mean attenuation in the ascending aorta, descending aorta, and pulmonary artery. Conclusion: The intravenous administration of iomeprol 400 provides higher attenuation of the coronary arteries and of the great arteries of the thorax as compared with iopromide 370 using the same injection parameters.
引用
收藏
页码:349 / 353
页数:5
相关论文
共 16 条
[1]   Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 206 (02) :455-464
[2]   Optimal contrast application for cardiac 4-detector-row computed tomography [J].
Becker, CR ;
Hong, C ;
Knez, A ;
Leber, A ;
Bruening, R ;
Schoepf, UJ ;
Reiser, MF .
INVESTIGATIVE RADIOLOGY, 2003, 38 (11) :690-694
[3]   Use of high concentration contrast media (HCCM): principles and rationale - body CT [J].
Brink, JA .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 :S53-S58
[4]   Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser [J].
Cademartiri, F ;
Mollet, N ;
van der Lugt, A ;
Nieman, K ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
EUROPEAN RADIOLOGY, 2004, 14 (02) :178-183
[5]   Parameters affecting bolus geometry in CTA: A review [J].
Cademartiri, F ;
van der Lugt, A ;
Luccichenti, G ;
Pavone, P ;
Krestin, GP .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (04) :598-607
[6]   Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique [J].
Cademartiri, F ;
Nieman, K ;
van der Lugt, A ;
Raaijmakers, RH ;
Mollet, N ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2004, 233 (03) :817-823
[7]   Intravenous contrast material administration at helical 16-detector row CT coronary angiography: Effect of iodine concentration on vascular attenuation [J].
Cademartiri, F ;
Mollet, NR ;
van der Lugt, A ;
McFadden, EP ;
Stijnen, T ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2005, 236 (02) :661-665
[8]   Use of high concentration contrast media: principles and rationale - vascular district [J].
Fleischmann, D .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 :S88-S93
[9]   Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography [J].
Fleischmann, D ;
Rubin, GD ;
Bankier, AA ;
Hittmair, K .
RADIOLOGY, 2000, 214 (02) :363-371
[10]   New technical developments in multislice CT - Part 1: Approaching isotropic resolution with sub-millimeter 16-slice scanning [J].
Flohr, T ;
Stierstorfer, K ;
Bruder, H ;
Simon, J ;
Schaller, S .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (07) :839-845