Italian multicenter, prospective study to evaluate the negative predictive value of 16-and 64-slice MDCT imaging in patients scheduled for coronary angiography (NIMISCAD-Non Invasive Multicenter Italian Study for Coronary Artery Disease)

被引:56
作者
Marano, Riccardo [1 ]
De Cobelli, Francesco [2 ]
Floriani, Irene [3 ]
Becker, Christoph [4 ]
Herzog, Christopher [5 ]
Centonze, Maurizio [6 ]
Morana, Giovanni [7 ]
Gualdi, Gian Franco [8 ]
Ligabue, Guido [9 ]
Pontone, Gianluca [10 ]
Catalano, Carlo [11 ]
Chiappino, Dante [12 ]
Midiri, Massimo [13 ]
Simonetti, Giovanni [14 ]
Marchisio, Filippo [15 ]
Olivetti, Lucio [16 ]
Fattori, Rossella [17 ]
Bonomo, Lorenzo
Del Maschio, Alessandro [2 ]
机构
[1] Catholic Univ, A Gemelli Hosp, Inst Radiol, Dept Bioimaging & Radiol Sci, I-00168 Rome, Italy
[2] Univ Vita Salute San Raffaele, S Raffaele Sci Inst, Milan, Italy
[3] Mario Negri Inst Pharmacol Res, Milan, Italy
[4] Univ Munich, Munich, Germany
[5] Univ Frankfurt, Frankfurt, Germany
[6] Santa Chiara Hosp, Trento, Italy
[7] Ca Foncello Hosp, Treviso, Italy
[8] Univ Roma La Sapienza, DEA Umberto Hosp I, Rome, Italy
[9] Univ Modena & Reggio Emilia, Modena, Italy
[10] Ctr Cardiol Monzino, Milan, Italy
[11] Univ Roma La Sapienza, Umberto Hosp I, Rome, Italy
[12] G Pasquinucci Hosp, Massa, Italy
[13] Univ Palermo, DIBIMEL, Palermo, Italy
[14] Univ Roma Tor Vergata, Rome, Italy
[15] Univ Turin, Turin, Italy
[16] Ist Ospitalieri Cremona, Cremona, Italy
[17] S Orsola Univ Hosp, Bologna, Italy
关键词
Multidetector CT; Coronary artery disease; Cardiac CT; SPIRAL COMPUTED-TOMOGRAPHY; STABLE ANGINA-PECTORIS; ISCHEMIC-HEART-DISEASE; DIAGNOSTIC-ACCURACY; PERFORMANCE EVALUATION; PRETEST PROBABILITY; INITIAL-EXPERIENCE; 1ST EXPERIENCE; CT; STENOSES;
D O I
10.1007/s00330-008-1239-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This was a prospective, multicenter study designed to evaluate the utility of MDCT in the diagnosis of coronary artery disease (CAD) in patients scheduled for elective coronary angiography (CA) using different MDCT systems from different manufacturers. Twenty national sites prospectively enrolled 367 patients between July 2004 and June 2006. Computed tomography (CT) was performed using a standardized/optimized scan protocol for each type of MDCT system (a parts per thousand yen16 slices) and compared with quantitative CA performed within 2 weeks of MDCT. A total of 284 patients (81%) were studied by 16-slice MDCT systems, while 66 patients (19%) by 64-slice MDCT scanners. The primary analysis was on-site/off-site evaluation of the negative predictive value (NPV) on a per-patient basis. Secondary analyses included on-site evaluation on a per-artery and per-segment basis. On-site evaluation included 327 patients (CAD prevalence 58%). NPV, positive predictive value (PPV), sensitivity, specificity, and diagnostic accuracy (DA) were 0.91 (95% CI 0.85-0.95), 0.91 (95% CI 0.86-0.95), 0.94 (95% CI 0.89-0.97), 0.88 (95% CI 0.81-0.93), and 0.91 (95% CI 0.88-0.94), respectively. Off-site analysis included 295 patients (CAD prevalence 56%). NPV, PPV, sensitivity, specificity, and DA were 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), 0.73 (95% CI 0.65-0.79), 0.93 (95% CI 0.87-0.97), and 0.82 (95% CI 0.77-0.86), respectively. The results of this study demonstrate the utility of MDCT in excluding significant CAD even when conducted by centers with varying degrees of expertise and using different MDCT machines.
引用
收藏
页码:1114 / 1123
页数:10
相关论文
共 43 条
[31]   Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography [J].
Nieman, K ;
Cademartiri, F ;
Lemos, PA ;
Raaijmakers, R ;
Pattynama, PMT ;
de Feyter, PJ .
CIRCULATION, 2002, 106 (16) :2051-2054
[32]   Coronary angiography with multi-slice computed tomography [J].
Nieman, K ;
Oudkerk, M ;
Rensing, BJ ;
van Ooijen, P ;
Munne, A ;
van Geuns, RJ ;
de Feyter, PJ .
LANCET, 2001, 357 (9256) :599-603
[33]   Accuracy of 64-MDCT in the diagnosis of ischemic heart disease [J].
Nikolaou, K ;
Knez, A ;
Rist, C ;
Wintersperger, BJ ;
Leber, A ;
Johnson, T ;
Reiser, MF ;
Becker, CR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (01) :111-117
[34]   Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris [J].
Pugliese, F ;
Mollet, NRA ;
Runza, G ;
van Mieghem, C ;
Meijboom, WB ;
Malagutti, P ;
Baks, T ;
Krestin, GP ;
deFeyter, PJ ;
Cademartiri, F .
EUROPEAN RADIOLOGY, 2006, 16 (03) :575-582
[35]   Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography [J].
Raff, GL ;
Gallagher, MJ ;
O'Neill, W ;
Goldstein, JA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (03) :552-557
[36]   Usefulness of multidetector row spiral computed tomography with 64-x 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses [J].
Ropers, D ;
Rixe, J ;
Anders, K ;
Küttner, A ;
Baum, U ;
Bautz, W ;
Daniel, WG ;
Achenbach, S .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (03) :343-348
[37]   Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction [J].
Ropers, D ;
Baum, U ;
Pohle, K ;
Anders, K ;
Ulzheimer, S ;
Ohnesorge, B ;
Schlundt, C ;
Bautz, W ;
Daniel, WG ;
Achenbach, S .
CIRCULATION, 2003, 107 (05) :664-666
[38]   Diagnostic accuracy of rubidium-82 myocardial perfusion imaging with hybrid positron emission tomography/computed tomography in the detection of coronary artery disease [J].
Sampson, Uchechukwu K. ;
Dorbala, Sharmila ;
Limaye, Atul ;
Kwong, Raymond ;
Di Carli, Marcelo F. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (10) :1052-1058
[39]   Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control [J].
Scheffel, Hans ;
Alkadhi, Hatem ;
Plass, Andre ;
Vachenauer, Robert ;
Desbiolles, Lotus ;
Gaemperli, Oliver ;
Schepis, Tiziano ;
Frauenfelder, Thomas ;
Schertler, Thomas ;
Husmann, Lars ;
Grunenfelder, Juerg ;
Genoni, Michele ;
Kaufmann, Philipp A. ;
Marincek, Borut ;
Leschka, Sebastian .
EUROPEAN RADIOLOGY, 2006, 16 (12) :2739-2747
[40]   Heart disease and stroke statistics - 2006 update - A report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee [J].
Thom, T ;
Haase, N ;
Rosamond, W ;
Howard, VJ ;
Rumsfeld, J ;
Manolio, T ;
Zheng, ZJ ;
Flegal, K ;
O'Donnell, C ;
Kittner, S ;
Lloyd-Jones, D ;
Goff, DC ;
Hong, YL ;
Adams, R ;
Friday, G ;
Furie, K ;
Gorelick, P ;
Kissela, B ;
Marler, J ;
Meigs, J ;
Roger, V ;
Sidney, S ;
Sorlie, P ;
Steinberger, J ;
Wasserthiel-Smoller, S ;
Wilson, M ;
Wolf, P .
CIRCULATION, 2006, 113 (06) :E85-E151