Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D)

被引:74
作者
Chen, Marcus Y. [1 ]
Steigner, Michael L. [2 ]
Leung, Steve W. [1 ]
Kumamaru, Kanako K. [2 ]
Schultz, Kurt [3 ]
Mather, Richard T. [3 ]
Arai, Andrew E. [1 ]
Rybicki, Frank J. [2 ]
机构
[1] NHLBI, Adv Cardiovasc Imaging Lab, Cardiovasc & Pulm Branch, Dept Hlth & Human Serv,NIH, Bethesda, MD 20892 USA
[2] Harvard Univ, Brigham & Womens Hosp, Appl Imaging Sci Lab, Dept Radiol,Med Sch, Boston, MA 02115 USA
[3] Toshiba Med Res Inst, Vernon Hills, IL USA
关键词
Coronary imaging; Computed tomography; Angiography; Image reconstruction; Radiation dose; IMAGE QUALITY; RECONSTRUCTION TECHNIQUE; MYOCARDIAL-PERFUSION; COMPUTED-TOMOGRAPHY; DIAGNOSTIC PERFORMANCE; 320-MDCT ANGIOGRAPHY; CORE320; MULTICENTER; CARDIAC CT; CHEST CT; FEASIBILITY;
D O I
10.1007/s10554-013-0190-1
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
To compare the image quality of coronary CT angiography (CTA) studies between standard filtered back projection (FBP) and adaptive iterative dose reduction in three-dimensions (AIDR3D) reconstruction using CT noise additional software to simulate reduced radiation exposure. Images from 93 consecutive clinical coronary CTA studies were processed utilizing standard FBP, FBP with 50 % simulated dose reduction (FBP50 %), and AIDR3D with simulated 50 % dose reduction (AIDR50 %). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured within 5 regions-of-interest, and image quality for each reconstruction strategy was assessed by two independent readers using a 4-point scale. Compared to FBP, the SNR measured from the AIDR50 % images was similar or higher (airway: 38.3 +/- A 12.7 vs. 38.5 +/- A 14.5, p = 0.81, fat: 5.5 +/- A 1.9 vs. 5.4 +/- A 2.0, p = 0.20, muscle: 3.2 +/- A 1.2 vs. 3.1 +/- A 1.3, p = 0.38, aorta: 22.6 +/- A 9.4 vs. 20.2 +/- A 9.7, p < 0.0001, liver: 2.7 +/- A 1.0 vs. 2.3 +/- A 1.1, p < 0.0001), while the SNR of the FBP50 % images were all lower (p values < 0.0001). The CNR measured from AIDR50 % images was also higher than that from the FBP images for the aorta relative to muscle (20.5 +/- A 9.0 vs. 18.3 +/- A 9.2, p < 0.0001). The interobserver agreement in the image quality score was excellent (kappa = 0.82). The quality score was significantly higher for the AIDR50 % images compared to the FBP images (3.6 +/- A 0.6 vs. 3.3 +/- A 0.7, p = 0.004). Simulated radiation dose reduction applied to clinical coronary CTA images suggests that a 50 % reduction in radiation dose can be achieved with adaptive iterative dose reduction software with image quality that is at least comparable to images acquired at standard radiation exposure and reconstructed with filtered back projection.
引用
收藏
页码:1167 / 1175
页数:9
相关论文
共 38 条
[1]
Reduced exposure using asymmetric cone beam processing for wide area detector cardiac CT [J].
Bedayat, Arash ;
Rybicki, Frank J. ;
Kumamaru, Kanako ;
Powers, Sara L. ;
Signorelli, Jason ;
Steigner, Michael L. ;
Steveson, Chloe ;
Soga, Shigeyoshi ;
Adams, Kimberly ;
Mitsouras, Dimitrios ;
Clouse, Melvin ;
Mather, Richard T. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (02) :381-388
[2]
Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience [J].
Bittencourt, Marcio Sommer ;
Schmidt, Bernhard ;
Seltmann, Martin ;
Muschiol, Gerd ;
Ropers, Dieter ;
Daniel, Werner Guenther ;
Achenbach, Stephan .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) :1081-1087
[3]
Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[4]
Computed tomography-old ideas and new technology [J].
Fleischmann, Dominik ;
Boas, F. Edward .
EUROPEAN RADIOLOGY, 2011, 21 (03) :510-517
[5]
Image Quality and Radiation Dose Stratified by Patient Heart Rate for Coronary 64-and 320-MDCT Angiography [J].
Fujimoto, Shinichiro ;
Matsutani, Hideyuki ;
Kondo, Takeshi ;
Sano, Tomonari ;
Kumamaru, Kanako ;
Takase, Shinichi ;
Rybicki, Frank J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) :765-770
[6]
Diagnostic Performance of Combined Noninvasive Coronary Angiography and Myocardial Perfusion Imaging Using 320-MDCT: The CT Angiography and Perfusion Methods of the CORE320 Multicenter Multinational Diagnostic Study [J].
George, Richard T. ;
Arbab-Zadeh, Armin ;
Cerci, Rodrigo J. ;
Vavere, Andrea L. ;
Kitagawa, Kakuya ;
Dewey, Marc ;
Rochitte, Carlos E. ;
Arai, Andrew E. ;
Paul, Narinder ;
Rybicki, Frank J. ;
Lardo, Albert C. ;
Clouse, Melvin E. ;
Lima, Joao A. C. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (04) :829-837
[7]
CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT [J].
Gervaise, Alban ;
Osemont, Benoit ;
Lecocq, Sophie ;
Noel, Alain ;
Micard, Emilien ;
Felblinger, Jacques ;
Blum, Alain .
EUROPEAN RADIOLOGY, 2012, 22 (02) :295-301
[8]
SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT [J].
Halliburton, Sandra S. ;
Abbara, Suhny ;
Chen, Marcus Y. ;
Gentry, Ralph ;
Mahesh, Mahadevappa ;
Raff, Gilbert L. ;
Shaw, Leslee J. ;
Hausleiter, Joerg .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (04) :198-224
[9]
Assessment of an iterative reconstruction algorithm (SAFIRE) on image quality in pediatric cardiac CT datasets [J].
Han, B. Kelly ;
Grant, Katharine L. R. ;
Garberich, Ross ;
Sedlmair, Martin ;
Lindberg, Jana ;
Lesser, John R. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (03) :200-204
[10]
Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study [J].
Hara, Amy K. ;
Paden, Robert G. ;
Silva, Alvin C. ;
Kujak, Jennifer L. ;
Lawder, Holly J. ;
Pavlicek, William .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) :764-771