Dual-energy imaging using a digital scanned multi-slit system for mammography: evaluation of a differential beam filtering technique

被引:1
作者
Bornefalk, Hans [1 ]
Hemmendorff, Magnus [1 ]
Hjarn, Torbjorn [1 ]
机构
[1] KTH, Dept Phys, Stockholm, Sweden
来源
MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3 | 2006年 / 6142卷
关键词
D O I
10.1117/12.649513
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes a method for single exposure contrast-enhanced dual-energy imaging of tumors utilizing a scanned multi-slit system for digital mammography. This photon counting system employs an array of silicon strip detectors in an edge-on geometry. In the multi-slit setup, the line detectors and pre-collimator slits are aligned orthogonal to the scan direction. This geometry is advantageous to dual-energy imaging, since it allows differential filtering of the x-ray beam in the pre-collimator slits. A high-energy image is constructed from those lines where the filter material has been chosen to harden the x-ray beam and the low-energy image from the lines with a filter producing softer beams. Both images are obtained in the same scan, eliminating the need to change tube voltages and anode materials and minimizing the risk of motion artifacts. The method is illustrated on a purpose-built phantom and logarithmic subtraction of the images produces images essentially free of anatomical clutter with the contrast-enhanced targets clearly visible.
引用
收藏
页数:7
相关论文
共 17 条
[1]   ENERGY-SELECTIVE RECONSTRUCTIONS IN X-RAY COMPUTERIZED TOMOGRAPHY [J].
ALVAREZ, RE ;
MACOVSKI, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :733-744
[2]   Scatter rejection in scanned multi-slit digital mammography [J].
Åslund, M ;
Cederström, B ;
Lundqvist, M ;
Danielsson, M .
MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 :478-487
[3]  
BERGER MJ, 2003, XCOM PHOTON CROSS SE
[4]   Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV [J].
Boone, JM ;
Seibert, JA .
MEDICAL PHYSICS, 1997, 24 (11) :1661-1670
[5]   Use of iodine-based contrast media in digital full-field mammography -: Initial experience [J].
Diekmann, F ;
Diekmann, S ;
Taupitz, M ;
Bick, U ;
Winzer, KJ ;
Hüttner, C ;
Muller, S ;
Jeunehomme, F ;
Hamm, B .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (03) :342-345
[6]   INCORPORATION OF SCATTERED RADIATION INTO DUAL-ENERGY RADIOLOGIC THEORY AND APPLICATION TO MAMMOGRAPHY [J].
JOHNS, PC ;
BEAUREGARD, RM .
MEDICAL PHYSICS, 1994, 21 (09) :1455-1462
[7]   DUAL-ENERGY MAMMOGRAPHY - INITIAL EXPERIMENTAL RESULTS [J].
JOHNS, PC ;
DROST, DJ ;
YAFFE, MJ ;
FENSTER, A .
MEDICAL PHYSICS, 1985, 12 (03) :297-304
[8]   THEORETICAL OPTIMIZATION OF DUAL-ENERGY X-RAY-IMAGING WITH APPLICATION TO MAMMOGRAPHY [J].
JOHNS, PC ;
YAFFE, MJ .
MEDICAL PHYSICS, 1985, 12 (03) :289-296
[9]   Contrast-enhanced digital mammography: Initial clinical experience [J].
Jong, RA ;
Yaffe, MJ ;
Skarpathiotakis, M ;
Shumak, RS ;
Danjoux, NM ;
Gunesekara, A ;
Plewes, DB .
RADIOLOGY, 2003, 228 (03) :842-850
[10]   Quantitative evaluation of dual-energy digital mammography for calcification imaging [J].
Kappadath, SC ;
Shaw, CC .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12) :2563-2576