Reliability of diabetic patients' gait parameters in a challenging environment

被引:16
作者
Allet, L. [1 ,2 ,4 ,5 ]
Armand, S. [2 ,3 ]
de Bie, R. A. [4 ,5 ]
Golay, A. [2 ,6 ]
Monnin, D. [1 ,2 ]
Aminian, K. [7 ]
de Bruin, E. D. [8 ,9 ,10 ]
机构
[1] Univ Hosp Geneva, Dept Neurosci, CH-1211 Geneva, Switzerland
[2] Univ Geneva, Geneva, Switzerland
[3] Univ Hosp Geneva, Lab Kinesiol, CH-1211 Geneva, Switzerland
[4] Maastricht Univ, Dept Epidemiol, Maastricht, Netherlands
[5] Caphri Res Sch, Maastricht, Netherlands
[6] Univ Hosp Geneva, Serv Educ Chron Dis, CH-1211 Geneva, Switzerland
[7] Ecole Polytech Fed Lausanne, Lab Movement Anal & Measurement, Lausanne, Switzerland
[8] ETH, Inst Human Movement Sci & Sport, Zurich, Switzerland
[9] Univ Zurich Hosp, Dept Rheumatol, CH-8091 Zurich, Switzerland
[10] Univ Zurich Hosp, Inst Med Phys, CH-8091 Zurich, Switzerland
关键词
Diabetes; Gait; Reliability;
D O I
10.1016/j.gaitpost.2008.05.006
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Activities of daily life require us to move about in challenging environments and to walk on varied surfaces. Irregular terrain has been shown to influence gait parameters, especially,in a population at risk for falling. A precise portable measurement system would permit objective gait analysis under such conditions. The aims of this study are to (a) investigate the reliability of gait parameters measured with the Physilog (R) in diabetic patients walking on different surfaces (tar, grass, and stones); (b) identify the measurement error (precision); (c) identify the minimal clinical detectable change. Methods: 16 patients with Type 2 diabetes were measured twice within 8 days. After clinical examination patients walked, equipped with a Physilog (R), on the three aforementioned surfaces. Results: ICC for each surface was excellent for within-visit analyses (>0.938). Inter-visit ICC's (0.753) were excellent except for the knee range parameter (>0.503). The coefficient of variation (CV) was lower than 5% for most of the parameters. Bland and Altman Plots, SEM and SDC showed precise values, distributed around zero for all surfaces. Discussion: Good reliability of Physilog (R) measurements on different surfaces suggests that Physilog (R) could facilitate the study of diabetic patients' gait in conditions close to real-life situations. Gait parameters during complex locomotor activities (e.g. stair-climbing, curbs, slopes) have not yet been extensively investigated. Conclusion: Good reliability, small measurement error and values of minimal clinical detectable change recommend the utilization of Physilog (R) for the evaluation of gait parameters in diabetic patients. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:680 / 686
页数:7
相关论文
共 28 条
[11]   The development and test of a device for the reconstruction of 3-D position and orientation by means of a kinematic sensor assembly with rate gyroscopes and accelerometers [J].
Giansanti, D ;
Maccioni, G ;
Macellari, V .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (07) :1271-1277
[12]   Gait variability and fall risk in community-living older adults: A 1-year prospective study [J].
Hausdorff, JM ;
Rios, DA ;
Edelberg, HK .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (08) :1050-1056
[13]   Walking speed influences on gait cycle variability [J].
Jordan, Kimberlee ;
Challis, John H. ;
Newell, Karl M. .
GAIT & POSTURE, 2007, 26 (01) :128-134
[14]   Concurrent validity and intrasession reliability of the IDEEA accelerometry system for the quantification of spatiotemporal gait parameters [J].
Maffiuletti, Nicola A. ;
Gorelick, Mark ;
Quervain, Ines Kramers-de ;
Bizzini, Mario ;
Munzinger, Jeannette Petrich ;
Tomasetti, Samuele ;
Stacoff, Alex .
GAIT & POSTURE, 2008, 27 (01) :160-163
[15]   Reliability of the GAITRite® walkway system for the quantification of temporo-spatial parameters of gait in young and older people [J].
Menz, HB ;
Latt, MD ;
Tiedemann, A ;
Kwan, MMS ;
Lord, SR .
GAIT & POSTURE, 2004, 20 (01) :20-25
[16]   Reported and measured physical functioning in older inner-city diabetic African Americans [J].
Miller, DK ;
Lui, LYL ;
Perry, HM ;
Kaiser, FE ;
Morley, JE .
JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 1999, 54 (05) :M230-M236
[17]   Long-term monitoring of gait in Parkinson's disease [J].
Moore, Steven T. ;
MacDougall, Hamish G. ;
Gracies, Jean-Michel ;
Cohen, Helen S. ;
Ondo, William G. .
GAIT & POSTURE, 2007, 26 (02) :200-207
[18]   Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses [J].
Rankin, G ;
Stokes, M .
CLINICAL REHABILITATION, 1998, 12 (03) :187-199
[19]   Gait analysis in a challenging environment differentiates between fallers and nonfallers among older patients with peripheral neuropathy [J].
Richardson, JK ;
Thies, SB ;
DeMott, TK ;
Ashton-Miller, JA .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2005, 86 (08) :1539-1544
[20]   Interventions improve gait regularity in patients with peripheral neuropathy while walking on an irregular surface under low light [J].
Richardson, JK ;
Thies, SB ;
DeMott, TK ;
Ashton-Miller, JA .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2004, 52 (04) :510-515