On-line exit dose profile measurements by a diode linear array

被引:18
作者
Fiorino, C
Uleri, C
Cattaneo, GM
Calandrino, R
机构
[1] Servizio di Fisica Sanitaria, Istituto Scientifico H S Raffaele, Milano
[2] Servizio di Fisica Sanitaria, Istituto Scientifico H S Raffaele, 20132 Milano
关键词
D O I
10.1088/0031-9155/41/8/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The possibility of using a commercial diode linear array (EMS Schuster Inc.) in on-line portal dosimetry has been investigated. The system is composed of 88 equispaced diodes (distance between diodes, 0.5 cm; detection area, 2.5 x 2.5 mm(2)). The ability to measure exit dose profiles has been demonstrated by comparing relative exit dose profiles measured by an ionization chamber (NE 2571) with 'portal' profiles measured by the diode array on a number of homogeneous and inhomogeneous phantoms in 6 MV x-ray beams (from a Clinac Varian 6/100). The influence of the variation of the scattered radiation at the exit level with respect to the detector level has been discussed and investigated by varying the air gap (from 0 to 80 cm for a homogeneous phantom and from 0 to 25 cm for inhomogeneous phantoms) as well as the field width. A good agreement (maximum difference 3.8%; 2.5% when the array was positioned in contact with the phantoms) between 'portal' profiles and exit dose profiles in both homogeneous and inhomogeneous phantoms has been found if the array-phantom distance is kept below 7.5 cm. Results indicate that the system should be suitable for applications in transit dosimetry.
引用
收藏
页码:1291 / 1304
页数:14
相关论文
共 20 条
[1]   COMPENSATING FILTER DESIGN USING MEGAVOLTAGE RADIOGRAPHY [J].
DIXON, RL ;
EKSTRAND, KE ;
FERREE, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1979, 5 (02) :281-287
[2]   Dosimetric characteristics of a liquid-filled electronic portal imaging device [J].
Essers, M ;
Hoogervorst, BR ;
vanHerk, M ;
Lanson, H ;
Mijnheer, BJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1265-1272
[3]   EXIT DOSE MEASUREMENTS BY PORTAL FILM DOSIMETRY [J].
FIORINO, C ;
DELVECCHIO, A ;
CATTANEO, GM ;
FUSCA, M ;
LONGOBARDI, B ;
SIGNOROTTO, P ;
CALANDRINO, R .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (03) :336-340
[4]  
FIORINO C, 1995, PHYS MEDICA, V11, P67
[5]   MIDPLANE DOSE DETERMINATION USING IN-VIVO DOSE MEASUREMENTS IN COMBINATION WITH PORTAL IMAGING [J].
HUYSKENS, D ;
VANDAM, J ;
DUTREIX, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (07) :1089-1101
[6]   X-RAY SCATTER IN MEGAVOLTAGE TRANSMISSION RADIOGRAPHY - PHYSICAL CHARACTERISTICS AND INFLUENCE ON IMAGE QUALITY [J].
JAFFRAY, DA ;
BATTISTA, JJ ;
FENSTER, A ;
MUNRO, P .
MEDICAL PHYSICS, 1994, 21 (01) :45-60
[7]   THE USE OF AN ELECTRONIC PORTAL IMAGING DEVICE FOR EXIT DOSIMETRY AND QUALITY-CONTROL MEASUREMENTS [J].
KIRBY, MC ;
WILLIAMS, PC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (03) :593-603
[8]   MEASUREMENT POSSIBILITIES USING AN ELECTRONIC PORTAL IMAGING DEVICE [J].
KIRBY, MC ;
WILLIAMS, PC .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :237-243
[9]  
PAPANIKOLAU N, 1994, MED PHYS, V21, P877
[10]  
RIKNER G, 1983, THESIS UPPSALA U