Three-dimensional reconstruction of in vivo blood vessels in human skin using phase-resolved optical Doppler tomography

被引:38
作者
Zhao, YH [1 ]
Brecke, KM
Ren, HW
Ding, ZH
Nelson, JS
Chen, ZP
机构
[1] Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA
[2] Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92612 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
biomedical imaging; biomedical optics; optical coherence tomography; optical Doppler tomography;
D O I
10.1109/2944.983296
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Phase-resolved optical Doppler tomography (ODT) has very high sensitivity while maintaining a fast axial scanning rate, making it possible to reconstruct blood flow in three dimensions. Here we demonstrate an ODT system that employed novel signal-processing techniques to remove aliasing effects and artifacts caused by lateral scanning and target movement. The results show that these techniques not only simplified ODT, but also improved lateral scanning speed. Using these signal-processing techniques, three-dimensional images of in vivo blood vessels in human skin were then reconstructed.
引用
收藏
页码:931 / 935
页数:5
相关论文
共 7 条
[1]   Optical Doppler tomography [J].
Chen, ZP ;
Zhao, YH ;
Srinivas, SM ;
Nelson, JS ;
Prakash, N ;
Frostig, RD .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1999, 5 (04) :1134-1142
[2]   Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media [J].
Chen, ZP ;
Milner, TE ;
Dave, D ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (01) :64-66
[3]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[4]   Velocity-estimation accuracy and frame-rate limitations in color Doppler optical coherence tomography [J].
Kulkarni, MD ;
van Leeuwen, TG ;
Yazdanfar, S ;
Izatt, JA .
OPTICS LETTERS, 1998, 23 (13) :1057-1059
[5]   High-speed phase- and group-delay scanning with a grating-based phase control delay line [J].
Tearney, GJ ;
Bouma, BE ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (23) :1811-1813
[6]   Doppler standard deviation imaging for clinical monitoring of in vivo human skin blood flow [J].
Zhao, YH ;
Chen, ZP ;
Saxer, C ;
Shen, QM ;
Xiang, SH ;
de Boer, JF ;
Nelson, JS .
OPTICS LETTERS, 2000, 25 (18) :1358-1360
[7]   Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity [J].
Zhao, YH ;
Chen, ZP ;
Saxer, C ;
Xiang, SH ;
de Boer, JF ;
Nelson, JS .
OPTICS LETTERS, 2000, 25 (02) :114-116