Rapid monitoring of recombinant protein products: a comparison of current technologies

被引:83
作者
Baker, KN [1 ]
Rendall, MH
Patel, A
Boyd, P
Hoare, M
Freedman, RB
James, DC
机构
[1] Univ Kent, Res Sch Biosci, Canterbury CT2 7NJ, Kent, England
[2] GlaxoSmithKline Res & Dev Ltd, Beckenham BR3 3BS, Kent, England
[3] UCL, Adv Ctr Biochem Engn, London WC1E 7JE, England
[4] Univ Queensland, Dept Chem Engn, Brisbane, Qld 4072, Australia
关键词
D O I
10.1016/S0167-7799(01)01914-X
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Specific measurement of recombinant protein titer in a complex environment during industrial bioprocessing has traditionally relied on labor-intensive and time-consuming immunoassays. In recent years, however, developments in analytical technology have resulted in improved methods for protein product monitoring during bioprocessing. The choice of product-monitoring technology for a particular bioprocess will depend on a variety of assay factors and instrument-specific factors. In this article, we have compiled an overview of the advantages and disadvantages of the most commonly used technologies used: electrochemiluminescence, optical biosensors, rapid chromatography and nephelometry. The advantages of each technology for measuring both small and large recombinant therapeutic proteins are compared with a conventional enzyme-linked immunosorbent assay (ELISA) technique.
引用
收藏
页码:149 / 156
页数:8
相关论文
共 51 条
[1]   AUTOMATED REAL-TIME IMMUNOASSAY OF BIOMOLECULES [J].
AFEYAN, NB ;
GORDON, NF ;
REGNIER, FE .
NATURE, 1992, 358 (6387) :603-604
[2]  
Baker K, 1997, GENET ENG BIOTECHNOL, V17, P69
[3]  
Bernard DR, 1996, EUR J CLIN CHEM CLIN, V34, P847
[4]  
BLACKBURN GF, 1991, CLIN CHEM, V37, P1534
[5]   MULTICHANNEL FLOW-INJECTION-ANALYSIS BIOSENSOR SYSTEM FOR ONLINE MONITORING OF GLUCOSE, LACTATE, GLUTAMINE, GLUTAMATE AND AMMONIA IN ANIMAL-CELL CULTURE [J].
BLANKENSTEIN, G ;
SPOHN, U ;
PREUSCHOFF, F ;
THOMMES, J ;
KULA, MR .
BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 1994, 20 :291-307
[6]   DEVELOPMENT AND VALIDATION OF AN AUTOMATED PARTICLE-ENHANCED NEPHELOMETRIC IMMUNOASSAY METHOD FOR THE MEASUREMENT OF HUMAN PLASMA C1Q [J].
BORQUE, L ;
OLIVAN, V ;
IGUAZ, F .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1995, 9 (05) :302-307
[7]  
Caballero M, 1999, J CLIN LAB ANAL, V13, P301, DOI 10.1002/(SICI)1098-2825(1999)13:6<301::AID-JCLA9>3.0.CO
[8]  
2-3
[9]  
Cha HJ, 1999, BIOTECHNOL BIOENG, V65, P316, DOI 10.1002/(SICI)1097-0290(19991105)65:3&lt
[10]  
316::AID-BIT9&gt