Au-nanoparticles as an electrochemical sensing platform for aptamer-thrombin interaction

被引:57
作者
Suprun, Elena [1 ]
Shurnyantseva, Victoria [1 ]
Bulko, Tatiana [1 ]
Rachmetova, Svetlana [1 ]
Rad'ko, Sergei [1 ]
Bodoev, Nikolay [1 ]
Archakov, Alexander [1 ]
机构
[1] Russian Acad Med Sci, Inst Biomed Chem, Moscow 119121, Russia
关键词
Gold-nanoparticles; Aptamers; Thrombin; Stripping voltammetry; Electrochemical aptasensor;
D O I
10.1016/j.bios.2008.07.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel electrochemical method for the detection of bioaffinity interactions based on a gold-nanoparticles sensing platform and on the usage of stripping voltammetry technique was developed. The oxidation of gold surface (resulted in gold oxide formation) upon polarization served as a basis for analytical response. As a model, thrombin-thrombin binding aptamer couple was chosen. The aptamer was immobilized on a screen-printed electrode modified with gold-nano particles by avidin-biotin technology. Cathodic peak area was found proportional to thrombin quantity specifically adsorbed onto electrode surface. Sigmoid calibration curve as is typical for immunoassay was obtained, with thrombin detection limit of 10(-9) M. Linear range corresponds from 10(-8) to 10(-5) M thrombin concentration or 2 x 10(-14) to 2 x 10(-11) mol/electrode (R = 0.996). Binding of thrombin to an aptamer has also been detected using the ferricyanide/ferrocyanide redox couple as electrochemical indicator. (C) 2008 Published by Elsevier B.V.
引用
收藏
页码:825 / 830
页数:6
相关论文
共 44 条
[1]   Gold nanoparticle-based quantitative electrochemical detection of amplified human cytomegalovirus DNA using disposable microband electrodes [J].
Authier, L ;
Grossiord, C ;
Brossier, P ;
Limoges, B .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4450-4456
[2]   Antibody-antigenic peptide interactions monitored by SPR and QCM-D -: A model for SPR detection of IA-2 autoantibodies in human serum [J].
Ayela, Cedric ;
Roquet, Francoise ;
Valera, Lionel ;
Granier, Claude ;
Nicu, Liviu ;
Pugniere, Martine .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (12) :3113-3119
[3]   A novel electrochemical detection method for aptamer biosensors [J].
Bang, GS ;
Cho, S ;
Kim, BG .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (06) :863-870
[4]   Characterization of antibody-antigen interactions: Comparison between surface plasmon resonance measurements and high-mass matrix-assisted laser desorption/ionization mass spectrometry [J].
Bich, Claudia ;
Scott, Mike ;
Panagiotidis, Andreas ;
Wenzel, Ryan J. ;
Nazabal, Alexis ;
Zenobi, Renato .
ANALYTICAL BIOCHEMISTRY, 2008, 375 (01) :35-45
[5]   Amperometric immunosensors based on layer-by-layer assembly of gold nanoparticles and methylene blue on thiourea modified glassy carbon electrode for determination of human chorionic gonadotrophin [J].
Chai, Rong ;
Yuan, Ruo ;
Chai, Yaqin ;
Ou, Chaofeng ;
Cao, Shurui ;
Li, Xuelian .
TALANTA, 2008, 74 (05) :1330-1336
[6]   Functional aptamers and aptazymes in biotechnology, diagnostics, and therapy [J].
Famulok, Michael ;
Hartig, Jorg S. ;
Mayer, Gunter .
CHEMICAL REVIEWS, 2007, 107 (09) :3715-3743
[7]   Synthesis and electrochemical applications of gold nanoparticles [J].
Guo, Shaojun ;
Wang, Erkang .
ANALYTICA CHIMICA ACTA, 2007, 598 (02) :181-192
[8]   Myoglobin retains iron heme and near-native conformation in DDAB films prepared from pH 5 to 7 dispersions [J].
Guto, PM ;
Rusling, JF .
ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (03) :455-459
[9]   Detection of aptamer-protein interactions using QCM and electrochemical indicator methods [J].
Hianik, T ;
Ostatná, V ;
Zajacová, Z ;
Stoikova, E ;
Evtugyn, G .
BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2005, 15 (02) :291-295
[10]   Influence of ionic strength, pH and aptamer configuration for binding affinity to thrombin [J].
Hianik, Tibor ;
Ostatna, Veronika ;
Sonlajtnerova, Michaela ;
Grman, Igor .
BIOELECTROCHEMISTRY, 2007, 70 (01) :127-133