Spatial resolution, signal-to-noise ratio, and smoothing in multi-subject functional MRI studies

被引:36
作者
Scouten, A [1 ]
Papademetris, X [1 ]
Constable, RT [1 ]
机构
[1] Yale Univ, Sch Med, Dept Biomed Engn, Anlyan Ctr, New Haven, CT 06520 USA
关键词
D O I
10.1016/j.neuroimage.2005.10.022
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Functional MRI is aimed at localizing cortical activity to understand the role of specific cortical regions, providing insight into the neurophysiological underpinnings of brain function. Scientists developing fMRI methodology seek to improve detection of subtle activations and to spatially localize these activations more precisely. Except for applications in the clinical environment, such as functional mapping in patients prior to neurosurgical intervention, most basic neuroscience studies involve group level random-effects analyses. Prior to grouping data, the data from each individual arc typically smoothed. A wide range of motivations for smoothing have been given including to match the spatial scale of hemodynamic responses, to normalize the error distribution (by the Central Limit Theorem) to improve the validity of inferences based on parametric tests, and, in the context of inter-subject averaging smoothing has been shown necessary to project the data down to a scale where homologies in functional anatomy are expressed across subjects. This work demonstrates that, for single-subject studies, if smoothing is to be employed, the data should be acquired at lower resolutions to maximize SNR. The benefits of a low-resolution acquisition are limited by partial volume effects and by the weak impact of resolution-dependent noise oil the overall group level statistics. Given that inter-subject noise dominates across a range of tasks, improvements in within-subject noise, through changes in acquisition strategy or even moving to higher field strength, may do little to improve group statistics. Such improvements however may greatly impact single-subject studies such as those used in neurosurgical planning. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:787 / 793
页数:7
相关论文
共 16 条
[1]   Repetition time in echo planar functional MRI [J].
Constable, RT ;
Spencer, DD .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) :748-755
[2]   Estimating sample size in functional MRI (fMRI) neuroimaging studies: Statistical power analyses [J].
Desmond, JE ;
Glover, GH .
JOURNAL OF NEUROSCIENCE METHODS, 2002, 118 (02) :115-128
[3]  
FRISTON KJ, IN PRESS HUMAN BRAIN
[4]   Retrospective evaluation of intersubject brain registration [J].
Hellier, P ;
Barillot, C ;
Corouge, I ;
Gibaud, B ;
Le Goualher, G ;
Collins, DL ;
Evans, A ;
Malandaln, G ;
Ayache, N ;
Christensen, GE ;
Johnson, HJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (09) :1120-1130
[5]  
HELLIER P, 2001, MICCAI, P369
[6]   Mapping cortical colunmar structures using fMRI [J].
Kim, SG ;
Duong, TQ .
PHYSIOLOGY & BEHAVIOR, 2002, 77 (4-5) :641-644
[7]   Neuroimaging at 1.5 T and 3.0 T:: Comparison of oxygenation-sensitive magnetic resonance imaging [J].
Krüger, G ;
Kastrup, A ;
Glover, GH .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :595-604
[8]   Physiological noise in oxygenation-sensitive magnetic resonance imaging [J].
Krüger, G ;
Glover, GH .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) :631-637
[9]   Ocular dominance in human V1 demonstrated by functional magnetic resonance imaging [J].
Menon, RS ;
Ogawa, S ;
Strupp, JP ;
Ugurbil, K .
JOURNAL OF NEUROPHYSIOLOGY, 1997, 77 (05) :2780-2787
[10]   Reducing inhomogeneity artifacts in functional MRI of human brain activation - Thin sections vs gradient compensation [J].
Merboldt, KD ;
Finsterbusch, J ;
Frahm, J .
JOURNAL OF MAGNETIC RESONANCE, 2000, 145 (02) :184-191