Flow-through immunoassay system for determination of staphylococcal protein A

被引:12
作者
Abdel-Hamid, I [1 ]
Ghindilis, AL [1 ]
Atanasov, P [1 ]
Wilkins, E [1 ]
机构
[1] Univ New Mexico, Dept Chem & Nucl Engn, Albuquerque, NM 87131 USA
关键词
amperometric immunosensor; protein A; Staphylococcus aureus;
D O I
10.1080/00032719908542879
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric immunosensor for fast immunoassay of protein A has been developed. The disposable immunoelectrode consists of highly dispersed carbon modified by immobilized anti-protein A antibodies. The now-through technique permits high automation of the entire measuring procedure. The detection is based on peroxidase-labeled anti-IgG antibodies captured by the immunoelectrode as a result of immunointeraction. The immunoassay employing a 'sandwich' scheme for the determination of different proteins with a detection limit in the nanomolar range is demonstrated. The immunosensor allows fast determination of protein A with an overall analysis time as low as 22 min. It can be further developed for Staphylococcus aureus assay based on the protein A expressed by this microorganism. The immunoassay system can be arranged as a portable device for fast analyses. The environmental application of the device is associated with on-site monitoring of bacterial contamination under field conditions.
引用
收藏
页码:1081 / 1094
页数:14
相关论文
共 12 条
  • [1] DETECTION OF STAPHYLOCOCCUS-AUREUS WITH BIOTINYLATED MONOCLONAL-ANTIBODIES DIRECTED AGAINST STAPHYLOCOCCAL TNASE COMPLEXED TO AVIDIN-PEROXIDASE IN A RAPID SANDWICH ENZYME-LINKED IMMUNOFILTRATION ASSAY (SELIFA)
    BRAKSTAD, OG
    MAELAND, JA
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 1993, 39 (02) : 128 - 134
  • [2] THE PRESENCE OF BACTERIAL-VIRUS IN GROUNDWATER AND TREATED DRINKING-WATER
    DUTKA, BJ
    PALMATEER, GA
    MEISSNER, SM
    JANZEN, EM
    SAKELLARIS, M
    [J]. ENVIRONMENTAL POLLUTION, 1990, 63 (04) : 293 - 298
  • [3] EMDE KME, 1991, RES J WATER POLLUT C, V63, P730
  • [4] Flow-through amperometric immunosensor: Fast 'sandwich' scheme immunoassay
    Ghindilis, AL
    Krishnan, R
    Atanasov, P
    Wilkins, E
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (05) : 415 - 423
  • [5] RAPID METHODS FOR IDENTIFICATION OF STAPHYLOCOCCUS-AUREUS WHEN BOTH HUMAN AND ANIMAL STAPHYLOCOCCI ARE TESTED - COMPARISON WITH A NEW IMMUNOENZYMATIC ASSAY
    GUARDATI, MC
    GUZMAN, CA
    PIATTI, G
    PRUZZO, C
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (06) : 1606 - 1608
  • [6] HICKS CR, 1994, J AM VET MED ASSOC, V204, P255
  • [7] FAST AMPEROMETRIC IMMUNOASSAY UTILIZING HIGHLY DISPERSED ELECTRODE MATERIAL
    KRISHNAN, R
    GHINDILIS, AL
    ATANASOV, P
    WILKINS, E
    [J]. ANALYTICAL LETTERS, 1995, 28 (14) : 2459 - 2474
  • [8] Fast amperometric immunoassay for hantavirus infection
    Krishnan, R
    Ghindilis, AL
    Atanasov, P
    Wilkins, E
    Montoya, J
    Koster, FT
    [J]. ELECTROANALYSIS, 1996, 8 (12) : 1131 - 1134
  • [9] AN IMPROVED AMPEROMETRIC IMMUNOSENSOR FOR THE DETECTION AND ENUMERATION OF PROTEIN-A-BEARING STAPHYLOCOCCUS-AUREUS
    MIRHABIBOLLAHI, B
    BROOKS, JL
    KROLL, RG
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 1990, 11 (03) : 119 - 122
  • [10] DEVELOPMENT AND PERFORMANCE OF AN ENZYME-LINKED AMPEROMETRIC IMMUNOSENSOR FOR THE DETECTION OF STAPHYLOCOCCUS-AUREUS IN FOODS
    MIRHABIBOLLAHI, B
    BROOKS, JL
    KROLL, RG
    [J]. JOURNAL OF APPLIED BACTERIOLOGY, 1990, 68 (06): : 577 - 585