Increasing conclusiveness of metabonomic studies by cheminformatic preprocessing of capillary electrophoretic data on urinary nucleoside profiles

被引:22
作者
Szymanska, E.
Markuszewski, M. J.
Capron, X.
van Nederkassel, A. -M.
Vander Heyden, Y.
Markuszewski, M.
Krajka, K.
Kaliszan, R.
机构
[1] Med Univ Gdansk, Dept Biopharmaceut & Pharmacodynam, PL-80416 Gdansk, Poland
[2] Vrije Univ Brussel VIB, Dept Analyt Chem & Pharmaceut Technol, B-1090 Brussels, Belgium
[3] Med Univ Gdansk, Dept Urol, PL-80402 Gdansk, Poland
关键词
metabonomics; modified nucleosides; urogenital cancer; metabolic profiling; data preprocessing;
D O I
10.1016/j.jpba.2006.08.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nowadays. bioinformatics offers advanced tools and procedures of data mining aimed at finding consistent patterns or systematic relationships between variables. Numerous metabolites concentrations can readily be determined in a given biological system by high-throughput analytical methods. However, such row analytical data comprise noninformative components due to many disturbances normally occurring in analysis of biological samples. To eliminate those unwanted original analytical data components advanced chemometric data preprocessing methods might be of help. Here, such methods are applied to electrophoretic nucleoside profiles in urine samples of cancer patients and healthy volunteers. The electrophoretic nucleoside profiles were obtained under following conditions: 100 mM borate, 72.5 mM phosphate, 160 mM SDS, pH 6.7; 25 kV voltage, 30 degrees C temperature; untreated fused silica capillary 70 cm effective length, 50 mu m I.D. Different most advanced preprocessing tools were applied for baseline correction, denoising and alignment of electrophoretic data. That approach was compared to standard procedure of electrophoretic peak integration. The best results of preprocessing were obtained after application of the so-called correlation optimized warping (COW) to align the data. The principal component analysis (PCA) of preprocessed data provides a clearly better consistency of the nucleoside electrophoretic profiles with health status of subjects than PCA of peak areas of original data (without preprocessing). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:413 / 420
页数:8
相关论文
共 34 条
[1]   Overview of the status and applications of capillary electrophoresis to the analysis of small molecules [J].
Altria, KD ;
Elder, D .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1023 (01) :1-14
[2]   Chromatographic alignment by warping and dynamic programming as a pre-processing tool for PARAFAC modelling of liquid chromatography-mass spectrometry data [J].
Bylund, D ;
Danielsson, R ;
Malmquist, G ;
Markides, KE .
JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (02) :237-244
[3]   Urinary electrophoretic profiles from chronic fatigue syndrome and chronic fatigue syndrome/fibromyalgia patients: a pilot study for achieving their normalization [J].
Casado, B ;
Zanone, C ;
Annovazzi, L ;
Iadarola, P ;
Whalen, G ;
Baraniuk, JN .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 814 (01) :43-51
[4]   Chromatographic preprocessing of GC-MS data for analysis of complex chemical mixtures [J].
Christensen, JH ;
Mortensen, J ;
Hansen, AB ;
Andersen, O .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1062 (01) :113-123
[5]   Parametric time warping [J].
Eilers, PHC .
ANALYTICAL CHEMISTRY, 2004, 76 (02) :404-411
[6]   Correction of retention time shifts for chromatographic fingerprints of herbal medicines [J].
Gong, F ;
Liang, YZ ;
Fung, YS ;
Chau, FT .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1029 (1-2) :173-183
[7]   Metabolomics by numbers: acquiring and understanding global metabolite data [J].
Goodacre, R ;
Vaidyanathan, S ;
Dunn, WB ;
Harrigan, GG ;
Kell, DB .
TRENDS IN BIOTECHNOLOGY, 2004, 22 (05) :245-252
[8]   Micellar electrokinetic capillary chromatography and data alignment analysis: a new tool in urine profiling [J].
Guillo, C ;
Barlow, D ;
Perrett, D ;
Hanna-Brown, M .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1027 (1-2) :203-212
[9]   Micellar electrokinetic chromatographic and capillary zone electrophoretic methods for screening urinary biomarkers of human disorders: A critical review of the state-of-the-art [J].
Iadarola, P ;
Cetta, G ;
Luisetti, M ;
Annovazzi, L ;
Casado, B ;
Baraniuk, J ;
Zanone, C ;
Viglio, S .
ELECTROPHORESIS, 2005, 26 (4-5) :752-766
[10]   High-speed peak matching algorithm for retention time alignment of gas chromatographic data for chemometric analysis [J].
Johnson, KJ ;
Wright, BW ;
Jarman, KH ;
Synovec, RE .
JOURNAL OF CHROMATOGRAPHY A, 2003, 996 (1-2) :141-155