Development of a Selective ESI-MS Derivatization Reagent: Synthesis and Optimization for the Analysis of Aldehydes in Biological Mixtures

被引:109
作者
Eggink, Mark [1 ]
Wijtmans, Maikel [2 ]
Ekkebus, Reggy [1 ]
Lingeman, Henk [1 ]
de Esch, Iwan J. P. [2 ]
Kool, Jeroen [1 ]
Niessen, Wilfried M. A. [1 ]
Irth, Hubertus [1 ]
机构
[1] Vrije Univ Amsterdam, Fac Sci, Leiden Amsterdam Ctr Drug Res, Sect Analyt Chem & Appl Spect,Dept Chem, NL-1081 HV Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Med Chem Sect, Dept Pharmacochem, NL-1081 HV Amsterdam, Netherlands
关键词
D O I
10.1021/ac801429w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In LC-MS, derivatization is primarily used to improve ionization characteristics, especially for analytes that are not (efficiently) ionized by ESI or APCI such as aldehydes, sugars, and steroids. Derivatization strategies are then directed at the incorporation of a group with a permanent charge. A compound class that typically requires derivatization prior to LC-MS is the group of small aliphatic aldehydes that are, for instance, analyzed as the key biomarkers for lipid peroxidation in organisms. Here we report the development of a new tailor-made, highly sensitive, and selective derivatization agent 4-(2-(trimethylammonio)ethoxy)benzenaminium halide (4-APC) for the quantification of aldehydes in biological matrixes with positive ESI-MS/MS without additional extraction procedures. 4-APC possesses an aniline moiety for a fast selective reaction with aliphatic aldehydes as well as a quaternary ammonium group for improved MS sensitivity. The derivatization reaction is a convenient one-pot reaction at a mild pH (5.7) and temperature (10 degrees C). As a result, an in-vial derivatization can be performed before analysis with an LC-MS/MS system. All aldehydes are derivatized within 30 min to a plateau, except malondialdehyde, which requires 300 min to reach a plateau. All derivatized aldehydes are stable for at least 35 h. Linearity was established between 10 and 500 nM and the limits of detection were in the 3-33 nM range for the aldehyde derivatives. Furthermore, the chosen design of these structures allows tandem MS to be used to monitor the typical losses of 59 and 87 from aldehyde derivatives, thereby enabling screening for aldehydes. Finally, of all aldehydes, pentanal and hexanal were detected at elevated levels in pooled healthy human urine samples.
引用
收藏
页码:9042 / 9051
页数:10
相关论文
共 41 条
[11]   On-line derivatization for resonance-enhanced multiphoton ionization time-of-flight mass spectrometry:: Detection of aliphatic aldehydes and amines via reactive coupling of aromatic photo ionization labels [J].
Fernandes-Whaley, M ;
Mühlberger, F ;
Whaley, A ;
Adam, T ;
Zimmermann, R ;
Rohwer, E ;
Walte, A .
ANALYTICAL CHEMISTRY, 2005, 77 (01) :1-10
[12]   Derivatisation for the characterisation of neutral oxosteroids by electrospray and matrix-assisted laser desorption/ionisation tandem mass spectrometry:: the Girard P derivative [J].
Griffiths, WJ ;
Liu, S ;
Alvelius, G ;
Sjövall, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (09) :924-935
[13]  
HABRIOUX G, 1978, ANN BIOL CLIN-PARIS, V36, P433
[14]   Measuring reactive species and oxidative damage in vivo and in cell culture:: how should you do it and what do the results mean? [J].
Halliwell, B ;
Whiteman, M .
BRITISH JOURNAL OF PHARMACOLOGY, 2004, 142 (02) :231-255
[15]   Derivatization with girard reagent t combined with LC-MS/MS for the sensitive detection of 5-formyl-2′-deoxyuridine in cellular DNA [J].
Hong, Haizheng ;
Wang, Yinsheng .
ANALYTICAL CHEMISTRY, 2007, 79 (01) :322-326
[16]   A modified Girard derivatizing reagent for universal profiling and trace analysis of aldehydes and ketones by electrospray ionization tandem mass spectrometry [J].
Johnson, David W. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (18) :2926-2932
[17]   Structure elucidation of 2,4-dinitrophenylhydrazone derivatives of carbonyl compounds in ambient air by HPLC/MS and multiple MS/MS using atmospheric chemical ionization in the negative ion mode [J].
Kölliker, S ;
Oehme, M ;
Dye, C .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1979-1985
[18]   Determination of plasma, urine, and bovine serum albumin low-molecular-weight carbonyl levels by capillary gas chromatography with electron-capture and mass-selective detection [J].
Konidari, CN ;
Giannopoulos, TS ;
Nanos, CG ;
Stalikas, CD .
ANALYTICAL BIOCHEMISTRY, 2005, 338 (01) :62-70
[19]   Measurement by reversed-phase high-performance liquid chromatography of malondialdehyde in normal human urine following derivatisation with 2,4-dinitrophenylhydrazine [J].
Korchazhkina, O ;
Exley, C ;
Spencer, SA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 794 (02) :353-362
[20]   DETERMINATION OF ALDEHYDES AND OTHER LIPID-PEROXIDATION PRODUCTS IN BIOLOGICAL SAMPLES BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
LUO, XP ;
YAZDANPANAH, M ;
BHOOI, N ;
LEHOTAY, DC .
ANALYTICAL BIOCHEMISTRY, 1995, 228 (02) :294-298