Design of a new dodecyl sulfate-selective electrode based on conductive polyaniline

被引:36
作者
Mousavi, MF
Shamsipur, M
Riahi, S
Rahmanifar, MS
机构
[1] Tarbiat Modares Univ, Dept Chem, Tehran, Iran
[2] Razi Univ, Dept Chem, Khorramshahr, Iran
关键词
D O I
10.2116/analsci.18.137
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, simple, sensitive, low cost and rapid potentiometric method for direct determination of ultra trace amounts of sodium dodecyl sulfate (SDS) with a new DS--selective electrode is reported. The electrode was prepared by electropolymerization of aniline in acidified DS- ion on the surface of a Pt electrode. The cyclic voltammetry (CV) was used for electropolymerization of polyaniline (PA) in the potential range of -200 to +1000 mV vs. Ag/AgCl. This sensor showed a Nernstian behavior (59.0 +/- 2.3 mV/decade) over a very wide linear range (1.0 x 10(-9) - 3.0 x 10(-6) M) with a detection limit of 1.0 x 10(-9) M. The response time of the electrode was 15 s for 1.0 x 10(-7) M of analyte; the electrode can be used for 4 weeks without any major deviation. This electrode can be used in the pH range of 3.5 - 9.8. The selectivity of electrode to DS- over some organic, inorganic and anionic surfactants was investigated with the fixed primary ion method. The results show that the electrode is highly selective to DS- ion over other ions. The proposed electrode was applied to the determination of DS- in real samples.
引用
收藏
页码:137 / 140
页数:4
相关论文
共 42 条
[21]   FLOW-INJECTION EXTRACTION WITHOUT PHASE-SEPARATION BASED ON DUAL-WAVELENGTH SPECTROPHOTOMETRY [J].
LIU, HH ;
DASGUPTA, PK .
ANALYTICA CHIMICA ACTA, 1994, 288 (03) :237-245
[22]   Determination of surfactant concentration using micellar enhanced fluorescence and flow injection titration [J].
Lucy, CA ;
Tsang, JSW .
TALANTA, 2000, 50 (06) :1283-1289
[23]   Potentiometric response of polyaniline electrode to dissolved nitrate [J].
Mazeikiene, R ;
Malinauskas, A .
SYNTHETIC METALS, 1997, 89 (01) :77-79
[24]  
Michelsen E.R., 1978, TENSIDE DETERGENTS, V15, P169
[25]   VOLTAMMETRIC DETERMINATION OF LEAD WITH A CHEMICALLY-MODIFIED CARBON-PASTE ELECTRODE WITH DIPHENYLTHIOCARBAZONE [J].
MOLINAHOLGADO, T ;
PINILLAMACIAS, JM ;
HERNANDEZHERNANDEZ, L .
ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) :117-122
[26]   PHOTOMETRIC TITRATION OF SMALL AMOUNTS OF CATIONIC SURFACTANTS IN AN AQUEOUS-MEDIUM [J].
MOTOMIZU, S ;
GAO, YH ;
UEMURA, K ;
ISHIHARA, S .
ANALYST, 1994, 119 (03) :473-477
[27]   FLOW-INJECTION METHOD FOR THE DETERMINATION OF ANIONIC SURFACTANTS AFTER LIQUID-LIQUID-EXTRACTION USING ON-TUBE VISIBLE ABSORPTION AND FLUORESCENCE DETECTION [J].
MOTOMIZU, S ;
KOBAYASHI, M .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :471-475
[28]   SPECTROPHOTOMETRIC DETERMINATION OF ANIONIC SURFACTANTS IN WATER AFTER SOLVENT-EXTRACTION COUPLED WITH FLOW-INJECTION [J].
MOTOMIZU, S ;
OSHIMA, M ;
KURODA, T .
ANALYST, 1988, 113 (05) :747-753
[29]   Lead ion-selective membrane electrode based on 1,10-dibenzyl-1,10-diaza-18-crown-6 [J].
Mousavi, MF ;
Sahari, S ;
Alizadeh, N ;
Shamsipur, M .
ANALYTICA CHIMICA ACTA, 2000, 414 (1-2) :189-194
[30]   A new PVC-based 1,10-dibenzyl-1,10-diaza-18-crown-6 selective electrode for detecting nickel(II) ion [J].
Mousavi, MF ;
Alizadeh, N ;
Shamsipur, M ;
Zohari, N .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 66 (1-3) :98-100