Position measurement of a cavity mirror using polarization spectroscopy

被引:8
作者
Hahtela, O [1 ]
Nera, K [1 ]
Tittonen, I [1 ]
机构
[1] Helsinki Univ Technol, Metrol Res Inst, FIN-02015 Helsinki, Finland
来源
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS | 2004年 / 6卷 / 03期
关键词
high-Q mechanical oscillator; optical interferometry; optomechanical sensor;
D O I
10.1088/1464-4258/6/3/019
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A high-reflectivity coated mechanical silicon oscillator with high quality value of the mechanical resonance was employed as a planar rear mirror in a Fabry-Perot interferometer. Active stabilization of the interferometer improves the stability of the resonance and makes it possible to perform sensitive interferometric measurements. The frequency locking of lasers to optical cavities requires typically the generation of an error signal with a typical steep slope at resonance. The Hansch-Couillaud locking method utilizes polarization spectroscopy by monitoring changes in the polarization of the light field reflected from the cavity. A polarization analyser detects dispersion shaped resonances which give the error signal for the electronic servo loop. The error signal contains information about the changes in the cavity length and thus the motion of the mechanical oscillator can be observed. The error signal was detected with the use of a spectrum analyser. The noise floor of the interferometer response indicates that the sensitivity of the optomechanical sensor or the minimum observable displacement in the mechanical oscillator position is Deltax(min) = 1.7 x 10(-14) m. This gives high enough sensitivity to observe the Brownian motion of the oscillator at room temperature.
引用
收藏
页码:S115 / S120
页数:6
相关论文
共 24 条
[11]   High-sensitivity optical measurement of mechanical Brownian motion [J].
Hadjar, Y ;
Cohadon, PF ;
Aminoff, CG ;
Pinard, M ;
Heidmann, A .
EUROPHYSICS LETTERS, 1999, 47 (05) :545-551
[12]   LASER FREQUENCY STABILIZATION BY POLARIZATION SPECTROSCOPY OF A REFLECTING REFERENCE CAVITY [J].
HANSCH, TW ;
COUILLAUD, B .
OPTICS COMMUNICATIONS, 1980, 35 (03) :441-444
[13]   Quantum nondemolition measurement by optomechanical coupling [J].
Heidmann, A ;
Hadjar, Y ;
Pinard, M .
APPLIED PHYSICS B-LASERS AND OPTICS, 1997, 64 (02) :173-180
[14]   Quantum noise in the position measurement of a cavity mirror undergoing Brownian motion [J].
Jacobs, K ;
Tittonen, I ;
Wiseman, HM ;
Schiller, S .
PHYSICAL REVIEW A, 1999, 60 (01) :538-548
[15]  
KITTEL C, 1958, ELEMENTARY STATISTIC, P141
[16]   SINGLE-CRYSTAL SILICON HIGH-Q TORSIONAL OSCILLATORS [J].
KLEIMAN, RN ;
KAMINSKY, GK ;
REPPY, JD ;
PINDAK, R ;
BISHOP, DJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (11) :2088-2091
[17]   Towards quantum superpositions of a mirror [J].
Marshall, W ;
Simon, C ;
Penrose, R ;
Bouwmeester, D .
PHYSICAL REVIEW LETTERS, 2003, 91 (13)
[18]   Dissipation measurements of vacuum-operated single-crystal silicon microresonators [J].
Mihailovich, RE ;
MacDonald, NC .
SENSORS AND ACTUATORS A-PHYSICAL, 1995, 50 (03) :199-207
[19]   QUANTUM-LIMITED MEASUREMENTS WITH THE ATOMIC-FORCE MICROSCOPE [J].
MILBURN, GJ ;
JACOBS, K ;
WALLS, DF .
PHYSICAL REVIEW A, 1994, 50 (06) :5256-5263
[20]   ROOM-TEMPERATURE TESTS OF AN OPTICAL TRANSDUCER FOR RESONANT GRAVITATIONAL-WAVE DETECTORS [J].
PANG, Y ;
RICHARD, JP .
APPLIED OPTICS, 1995, 34 (22) :4982-4988