Value of image subtraction in 3D gadolinium-enhanced MR angiography of the renal arteries

被引:29
作者
Leung, DA [1 ]
Pelkonen, P [1 ]
Hany, TF [1 ]
Zimmermann, G [1 ]
Pfammatter, T [1 ]
Debatin, JF [1 ]
机构
[1] Univ Zurich Hosp, Dept Diagnost Radiol, CH-8091 Zurich, Switzerland
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1998年 / 8卷 / 03期
关键词
renal arteries; MR; vascular studies; contrast agents; subtraction;
D O I
10.1002/jmri.1880080313
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to evaluate quantitatively and qualitatively the effect of image subtraction on the image quality of three-dimensional (3D) gadolinium-enhanced MR angiograms of the renal arteries. Breath-hold 3D gadolinium MR angiography (MRA) as well as conventional contrast angiography of the renal arteries was performed on 20 patients with suspected renovascular hypertension. MR angiograms were acquired before and during dynamic infusion of gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA). Contrast-enhanced images were compared with images that had undergone voxel-by-voxel signal intensity subtraction of contrast-enhanced data from precontrast data. One false positive finding for significant renal artery stenosis was recorded with MRA using conventional angiography as the gold standard. Image subtraction did not alter the diagnosis at MRA in any case. The mean contrast-to-noise ratio (CNR) was significantly higher (P < .05) on the subtraction MR angiograms compared to the nonsubtracted MR angiograms. There was no significant difference in the signal-to-noise ratio (SNR). Qualitative analysis revealed a significant improvement in image quality after image subtraction with respect to visualization of the distal renal arteries. In conclusion, image subtraction improves the quality of renal MRA in terms of both CNR and visualization of the distal renal arteries.
引用
收藏
页码:598 / 602
页数:5
相关论文
共 12 条
[1]   Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography [J].
Foo, TKF ;
Saranathan, M ;
Prince, MR ;
Chenevert, TL .
RADIOLOGY, 1997, 203 (01) :275-280
[2]   Evaluation of the aortoiliac and renal arteries: Comparison of breath-hold, contrast-enhanced, three-dimensional MR angiography with conventional catheter angiography [J].
Hany, TF ;
Debatin, JF ;
Leung, DA ;
Pfammatter, T .
RADIOLOGY, 1997, 204 (02) :357-362
[3]   Optimization of contrast timing for breath-hold three-dimensional MR angiography [J].
Hany, TF ;
McKinnon, GC ;
Leung, DA ;
Pfammatter, T ;
Debatin, JF .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (03) :551-556
[4]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[5]  
LEUNG DA, 1996, RADIOLOGY, V201, P569
[6]   Diagnosis of pulmonary embolism with magnetic resonance angiography [J].
Meaney, JFM ;
Weg, JG ;
Chenevert, TL ;
StaffordJohnson, D ;
Hamilton, BH ;
Prince, MR .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (20) :1422-1427
[7]   BREATH-HOLD GADOLINIUM-ENHANCED MR-ANGIOGRAPHY OF THE ABDOMINAL-AORTA AND ITS MAJOR BRANCHES [J].
PRINCE, MR ;
NARASIMHAM, DL ;
STANLEY, JC ;
CHENEVERT, TL ;
WILLIAMS, DM ;
MARX, V ;
CHO, KJ .
RADIOLOGY, 1995, 197 (03) :785-792
[8]   GADOLINIUM-ENHANCED MR AORTOGRAPHY [J].
PRINCE, MR .
RADIOLOGY, 1994, 191 (01) :155-164
[9]   Three-dimensional gadolinium-enhanced MR angiography of the thoracic aorta [J].
Prince, MR ;
Narasimham, DL ;
Jacoby, WT ;
Williams, DM ;
Cho, KJ ;
Marx, MV ;
Deeb, GM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (06) :1387-1397
[10]   ILIAC ARTERY NIR ANGIOGRAPHY - COMPARISON OF 3-DIMENSIONAL GADOLINIUM-ENHANCED AND 2-DIMENSIONAL TIME-OF-FLIGHT TECHNIQUES [J].
SNIDOW, JJ ;
AISEN, AM ;
HARRIS, VJ ;
TREROTOLA, SO ;
JOHNSON, MS ;
SAWCHUK, AP ;
DALSING, MC .
RADIOLOGY, 1995, 196 (02) :371-378