Comparative evaluation of bonded-silica reversed-phase columns for high-performance liquid chromatography using strongly basic compounds and alternative organic modifiers buffered at acid pH

被引:74
作者
McCalley, DV
机构
[1] Dept. of Chem. and Physical Sciences, Univ. of the W. of England, Frenchay
关键词
stationary phases; LC; mobile phase composition; organic modifiers; basic compounds;
D O I
10.1016/S0021-9673(96)01079-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of eight silica-based RP-HPLC columns evaluated previously with relatively high-pK(a) bases using isoeluotropic mixtures of either methanol, acetonitrile or tetrahydrofuran in combination with phosphate buffer pH 7.0, was further examined with the same solutes and mobile phases buffered at pH 3.0. Differences in column performance dependent on choice of organic modifier were shown to be considerably reduced at acid pH, although tetrahydrofuran again gave significantly better performance than acetonitrile or methanol. While differences between columns were less apparent at pH 3.0, some columns again clearly performed better than others. Furthermore, the ranking of columns according to average asymmetry of the set of basic compounds was found to vary somewhat with pH; thus column evaluation should be performed preferentially at the pH of intended use. The dependency of column performance on choice of solute was reduced, but still evident at pH 3.0. All solutes except pyridine gave superior results at acid pH. Solutes which were the most challenging probes at pH 7.0 were not necessarily the most difficult at pH 3.0.
引用
收藏
页码:169 / 178
页数:10
相关论文
共 20 条
[11]   Effect of organic solvent modifier and nature of solute on the performance of bonded silica reversed-phase columns for the analysis of strongly basic compounds by high-performance liquid chromatography [J].
McCalley, DV .
JOURNAL OF CHROMATOGRAPHY A, 1996, 738 (02) :169-179
[12]   INFLUENCE OF ORGANIC-SOLVENT MODIFIER AND SOLVENT STRENGTH ON PEAK SHAPE OF SOME BASIC COMPOUNDS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING A REVERSED-PHASE COLUMN [J].
MCCALLEY, DV .
JOURNAL OF CHROMATOGRAPHY A, 1995, 708 (02) :185-194
[13]   INFLUENCE OF ANALYTE STEREOCHEMISTRY AND BASICITY ON PEAK SHAPE OF BASIC COMPOUNDS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH REVERSED-PHASE COLUMNS, USING PYRIDINE AND ALKYL-SUBSTITUTED DERIVATIVES AS PROBE COMPOUNDS [J].
MCCALLEY, DV .
JOURNAL OF CHROMATOGRAPHY A, 1994, 664 (02) :139-147
[14]   ANALYSIS OF THE CINCHONA ALKALOIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - USE AS PROBES OF ACTIVITY TOWARDS BASIC COMPOUNDS SHOWN BY REVERSED-PHASE COLUMNS [J].
MCCALLEY, DV .
JOURNAL OF CHROMATOGRAPHY, 1986, 357 (01) :221-226
[15]   APPLICATION OF A COMPARATIVE-EVALUATION OF SEVERAL REVERSED-PHASE COLUMNS TO THE AUTOMATED-ANALYSIS OF CANDIDATE PHARMACEUTICALS [J].
MUTTON, IM .
JOURNAL OF CHROMATOGRAPHY A, 1995, 697 (1-2) :191-201
[16]  
Snyder J. J., 1979, INTRO MODERN LIQUID
[17]  
Snyder L., 2012, Practical Hplc method development, V2nd, DOI [10.1002/9781118592014.app2, DOI 10.1002/9781118592014.APP2]
[18]   COMPARISON OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHODS FOR THE ANALYSIS OF BASIC DRUGS [J].
VERVOORT, RJM ;
MARIS, FA ;
HINDRIKS, H .
JOURNAL OF CHROMATOGRAPHY, 1992, 623 (02) :207-220
[19]   IMPROVED COMPUTER ALGORITHM FOR CHARACTERIZING SKEWED CHROMATOGRAPHIC BAND BROADENING .2. RESULTS AND COMPARISONS [J].
YAU, WW ;
REMENTER, SW ;
BOYAJIAN, JM ;
DESTEFANO, JJ ;
GRAFF, JF ;
LIM, KB ;
KIRKLAND, JJ .
JOURNAL OF CHROMATOGRAPHY, 1993, 630 (1-2) :69-77
[20]  
ZENGBIAO L, 1996, ANAL CHEM, V68, P124