Digital Tomosynthesis of the Chest: Comparison of Patient Exposure Dose and Image Quality between Standard Default Setting and Low Dose Setting

被引:19
作者
Hwang, Hye Sun [2 ]
Chung, Myung Jin [1 ]
Lee, Kyung Soo [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
[2] Hallym Univ, Sacred Heart Hosp, Dept Radiol, Anyang 431070, South Korea
关键词
Digital radiography; Tomographic imaging; Radiation dose; RADIOGRAPHY; PERFORMANCE; REDUCTION; CT;
D O I
10.3348/kjr.2013.14.3.525
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Objective: To determine the optimum low dose (LD) digital tomosynthesis (DT) setting, and to compared the image quality of the LD DT with that of the standard default (SD) DT. Materials and Methods: Nine DT settings, by changing tube voltage, copper filter, and dose ratio, were performed for determining the LD setting. Among combinations of DT setting, a condition providing the lowest radiation dose was determined. Eighty artificial nodules Less than 1 cm in diameter (subcentimeter nodules: 40, micronodules less than 4 mm: 40) were attached to a Styrofoam and a diaphragm of the phantom. Among these, 38 nodules were located at the periphery of the lung (thin area) and 42 nodules were located at the paravertebral or sub-diaphragmatic area (thick area). Four observers counted the number of nodules detected in the thick and thin areas. The detection sensitivity in SD and LD settings were calculated separately. Data were analyzed statistically. Results: The lowest LD setting was a combination of 100 kVp, 0.3 mm additional copper filter, and a 1 : 5 dose ratio. The effective dose for the LD and SD settings were 62 mu Sv and 140 mu Sv, separately. A 56.7% dose reduction was achieved in the LD setting compared with the SD setting. Detection sensitivities were not different between the SD and the LD settings except between observers 1 and 2 for the detection of micronodules in the thick area. Conclusion: LD DT can be effective in nodule detection bigger than 4 mm without a significant decrease in image quality compared with SD DT.
引用
收藏
页码:525 / 531
页数:7
相关论文
共 20 条
[1]
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening [J].
Aberle, Denise R. ;
Adams, Amanda M. ;
Berg, Christine D. ;
Black, William C. ;
Clapp, Jonathan D. ;
Fagerstrom, Richard M. ;
Gareen, Ilana F. ;
Gatsonis, Constantine ;
Marcus, Pamela M. ;
Sicks, JoRean D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (05) :395-409
[2]
Effective dose to patients from chest examinations with tomosynthesis [J].
Bath, Magnus ;
Svalkvist, Angelica ;
von Wrangel, Alexa ;
Rismyhr-Olsson, Heidi ;
Cederblad, Ake .
RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) :153-158
[3]
Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[4]
CARMICHAEL JH, 1996, 16260 EUR EUR COMM
[5]
Digital tomosynthesis of the chest for lung nodule detection: Interim sensitivity results from an ongoing NIH-sponsored trial [J].
Dobbins, James T. ;
McAdams, H. Page ;
Song, Jae-Woo ;
Li, Christina M. ;
Godfrey, Devon J. ;
DeLong, David M. ;
Paik, Sang-Hyun ;
Martinez-Jimenez, Santiago .
MEDICAL PHYSICS, 2008, 35 (06) :2554-2557
[6]
Chest tomosynthesis: Technical principles and clinical update [J].
Dobbins, James T., III ;
McAdams, H. Page .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (02) :244-251
[7]
Digital x-ray tomosynthesis: current state of the art and clinical potential [J].
Dobbins, JT ;
Godfrey, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19) :R65-R106
[8]
Chest radiography: Optimization of X-ray spectrum for cesium iodide-amorphous silicon flat-panel detector [J].
Dobbins, JT ;
Samei, E ;
Chotas, HG ;
Warp, RJ ;
Baydush, AH ;
Floyd, CE ;
Ravin, CE .
RADIOLOGY, 2003, 226 (01) :221-230
[9]
Cancer risks from diagnostic radiology [J].
Hall, E. J. ;
Brenner, D. J. .
BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (965) :362-378
[10]
Chest radiography with a flat-panel detector:: Image quality with dose reduction after copper filtration [J].
Hamer, OW ;
Sirlin, CB ;
Strotzer, M ;
Borisch, I ;
Zorger, N ;
Feuerbach, S ;
Völk, M .
RADIOLOGY, 2005, 237 (02) :691-700