Minimally Invasive Cardiac Output Monitoring in the Perioperative Setting

被引:141
作者
Funk, Duane J. [1 ]
Moretti, Eugene W. [1 ]
Gan, Tong J. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Anesthesiol, Div Crit Care, Durham, NC 27710 USA
关键词
PULSE-CONTOUR ANALYSIS; RANDOMIZED CONTROLLED-TRIAL; PULMONARY-ARTERY CATHETER; CRITICALLY-ILL PATIENTS; TRANSPULMONARY THERMODILUTION TECHNIQUE; THORACIC ELECTRICAL BIOIMPEDANCE; ESOPHAGEAL DOPPLER ULTRASOUND; STROKE VOLUME VARIATION; GOAL-DIRECTED THERAPY; HOSPITAL STAY;
D O I
10.1213/ane.0b013e31818ffd99
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
With advancing age and increased co-morbidities in patients, the need for monitoring devices during the perioperative period that allow clinicians to track physiologic variables, such as cardiac output (CO), fluid responsiveness and tissue perfusion, is increasing. Until recently, the only tool available to anesthesiologists to monitor CO was either a pulmonary artery catheter or transesophageal echoSeveral cardiograph. devices devices have their limitations and devices (including esophageal Doppler monitors, for pulse contour analysis, indicator dilution, thoracic bioimpedance and partial non-rebreathing systems) have recently been marketed which have the ability to monitor CO noninvasively and, in some cases, assess the patient's ability to respond to fluid challenges. In this review, we will describe these new devices including the technology, studies on their efficacy and the limitations of their use.
引用
收藏
页码:887 / 897
页数:11
相关论文
共 79 条
[41]  
MARK JB, 1986, ANESTH ANALG, V65, P1013
[42]   Noninvasive cardiac output by partial CO2 rebreathing after severe chest trauma [J].
Maxwell, RA ;
Gibson, JB ;
Slade, JB ;
Fabian, TC ;
Proctor, KG .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 51 (05) :849-853
[43]   Randomised controlled trial assessing the impact of a nurse delivered, flow monitored protocol for optimisation of circulatory status after cardiac surgery [J].
McKendry, M ;
McGloin, H ;
Saberi, D ;
Caudwell, L ;
Brady, AR ;
Singer, M .
BMJ-BRITISH MEDICAL JOURNAL, 2004, 329 (7460) :258-261
[44]   Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure [J].
Michard, F ;
Boussat, S ;
Chemla, D ;
Anguel, N ;
Mercat, A ;
Lecarpentier, Y ;
Richard, C ;
Pinsky, MR ;
Teboul, JL .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (01) :134-138
[45]   Changes in arterial pressure duping mechanical ventilation [J].
Michard, F .
ANESTHESIOLOGY, 2005, 103 (02) :419-428
[46]   Comparison of continuous cardiac output measurements in patients after cardiac surgery [J].
Mielck, F ;
Buhre, W ;
Hanekop, G ;
Tirilomis, T ;
Hilgers, R ;
Sonntag, H .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (02) :211-216
[47]  
MYTHEN MG, 1995, ARCH SURG-CHICAGO, V130, P423
[48]   Lack of agreement between thermodilution and carbon dioxide-rebreathing cardiac output [J].
Nilsson, LB ;
Eldrup, N ;
Berthelsen, PG .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (06) :680-685
[49]   Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resection [J].
Noblett, S. E. ;
Snowden, C. P. ;
Shenton, B. K. ;
Horgan, A. F. .
BRITISH JOURNAL OF SURGERY, 2006, 93 (09) :1069-1076
[50]  
Nunn J.F., 1993, APPL RESP PHYSL, V4th