Visualization of vascular guidewires using MR tracking

被引:44
作者
Ladd, ME [1 ]
Zimmermann, GG [1 ]
McKinnon, GC [1 ]
von Schulthess, GK [1 ]
Dumoulin, CL [1 ]
Darrow, RD [1 ]
Hofmann, E [1 ]
Debatin, JF [1 ]
机构
[1] Univ Zurich Hosp, Dept Radiol, CH-8091 Zurich, Switzerland
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1998年 / 8卷 / 01期
关键词
interventional MR; guidewires; device visualization; MR tracking;
D O I
10.1002/jmri.1880080142
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MR tracking of a vascular guidewire sized for a .035-inch (.89-mm) catheter lumen was performed. The guidewire was actively tracked by incorporation of a miniature radiofrequency (RF) receive coil built into its tip. After in vitro validation, simultaneous tracking of the guidewire and a catheter was performed in the aortic and abdominal vessels of a swine at 1.5 T. The ability to track such a small device and the ability to simultaneously track multiple devices are significant steps towards vascular interventions under MR guidance.
引用
收藏
页码:251 / 253
页数:3
相关论文
共 11 条
[1]  
Ackerman JL., 1986, Proceedings of the 5th Annual Meeting of ISMRM, P1131
[2]   Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions [J].
Bakker, CJ ;
Hoogeveen, RM ;
Weber, J ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WP .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :816-820
[3]   REAL-TIME POSITION MONITORING OF INVASIVE DEVICES USING MAGNETIC-RESONANCE [J].
DUMOULIN, CL ;
SOUZA, SP ;
DARROW, RD .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (03) :411-415
[4]   SIGNAL-TO-NOISE RATIO OF NUCLEAR MAGNETIC-RESONANCE EXPERIMENT [J].
HOULT, DI ;
RICHARDS, RE .
JOURNAL OF MAGNETIC RESONANCE, 1976, 24 (01) :71-85
[5]   VASCULAR INTERVENTIONS GUIDED BY ULTRAFAST MR-IMAGING - EVALUATION OF DIFFERENT MATERIALS [J].
KOCHLI, VD ;
MCKINNON, GC ;
HOFMANN, E ;
VONSCHULTHESS, GK .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (03) :309-314
[6]   Guidewire antennas for MR fluoroscopy [J].
Ladd, ME ;
Erhart, P ;
Debatin, JF ;
Hofmann, E ;
Boesiger, P ;
vonSchulthess, GK ;
McKinnon, GC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (06) :891-897
[7]   INTRAVASCULAR MR TRACKING CATHETER - PRELIMINARY EXPERIMENTAL EVALUATION [J].
LEUNG, DA ;
DEBATIN, JF ;
WILDERMUTH, S ;
MCKINNON, GC ;
HOLTZ, D ;
DUMOULIN, CL ;
DARROW, RD ;
HOFMANN, E ;
VONSCHULTHESS, GK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) :1265-1270
[8]   REAL-TIME BIPLANAR NEEDLE TRACKING FOR INTERVENTIONAL MR-IMAGING PROCEDURES [J].
LEUNG, DA ;
DEBATIN, JF ;
WILDERMUTH, S ;
HESKE, N ;
DUMOULIN, CL ;
DARROW, RD ;
HAUSER, M ;
DAVIS, CP ;
VONSCHULTHESS, GK .
RADIOLOGY, 1995, 197 (02) :485-488
[9]   Towards active guidewire visualization in interventional magnetic resonance imaging [J].
McKinnon, GC ;
Debatin, JF ;
Leung, DA ;
Wildermuth, S ;
Holtz, DJ ;
vonSchulthess, GK .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1996, 4 (01) :13-18
[10]   Intravascular magnetic resonance imaging using a loopless catheter antenna [J].
Ocali, O ;
Atalar, E .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) :112-118