The Hip Society ALGORITHMIC APPROACH TO DIAGNOSIS AND MANAGEMENT OF METAL-ON-METAL ARTHROPLASTY

被引:108
作者
Lombardi, A. V., Jr. [1 ]
Barrack, R. L. [1 ]
Berend, K. R. [1 ]
Cuckler, J. M. [1 ]
Jacobs, J. J. [1 ]
Mont, M. A. [1 ]
Schmalzried, T. P. [1 ]
机构
[1] Joint Implant Surg Inc, New Albany, OH USA
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2012年 / 94B卷 / 11期
关键词
BEARINGS; WEAR;
D O I
10.1302/0301-620X.94B11.30680
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Since 1996 more than one million metal-on-metal articulations have been implanted worldwide. Adverse reactions to metal debris are escalating. Here we present an algorithmic approach to patient management. The general approach to all arthroplasty patients returning for follow-up begins with a detailed history, querying for pain, discomfort or compromise of function. Symptomatic patients should be evaluated for intra-articular and extra-articular causes of pain. In large head MoM arthroplasty, aseptic loosening may be the source of pain and is frequently difficult to diagnose. Sepsis should be ruled out as a source of pain. Plain radiographs are evaluated to rule out loosening and osteolysis, and assess component position. Laboratory evaluation commences with erythrocyte sedimentation rate and C-reactive protein, which may be elevated. Serum metal ions should be assessed by an approved facility. Aspiration, with manual cell count and culture/sensitivity should be performed, with cloudy to creamy fluid with predominance of monocytes often indicative of failure. Imaging should include ultrasound or metal artifact reduction sequence MRI, specifically evaluating for fluid collections and/or masses about the hip. If adverse reaction to metal debris is suspected then revision to metal or ceramic-on-polyethylene is indicated and can be successful. Delay may be associated with extensive soft-tissue damage and hence poor clinical outcome.
引用
收藏
页码:14 / 18
页数:5
相关论文
共 10 条
[1]
Brooks Peter, 2010, Orthopedics, V33, P646, DOI 10.3928/01477447-20100722-25
[2]
2008 John Charnley Award: Metal Ion Levels After Metal-on-Metal Total Hip Arthroplasty: A Randomized Trial [J].
Engh, C. Anderson, Jr. ;
MacDonald, Steven J. ;
Sritulanondha, Supatra ;
Thompson, Abigail ;
Naudie, Douglas ;
Engh, Charles A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (01) :101-111
[3]
The In Vivo Linear and Volumetric Wear of Hip Resurfacing Implants Revised for Pseudotumor [J].
Glyn-Jones, Sion ;
Roques, Anne ;
Taylor, Adrian ;
Kwon, Young-Min ;
McLardy-Smith, Peter ;
Gill, Harinderjit S. ;
Walter, William ;
Tuke, Mike ;
Murray, David .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (23) :2180-2188
[4]
MRI After Arthroplasty: Comparison of MAVRIC and Conventional Fast Spin-Echo Techniques [J].
Hayter, Catherine L. ;
Koff, Matthew F. ;
Shah, Parina ;
Koch, Kevin M. ;
Miller, Theodore T. ;
Potter, Hollis G. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) :W405-W411
[5]
The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses [J].
Heisel, C ;
Silva, M ;
Skipor, AK ;
Jacobs, JJ ;
Schmalzried, TP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (04) :781-787
[6]
Metal-on-metal Bearing Surfaces [J].
Jacobs, Joshua J. ;
Urban, Robert M. ;
Hallab, Nadim J. ;
Skipor, Anastasia K. ;
Fischer, Alfons ;
Wimmer, Markus A. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (02) :69-76
[7]
Can cobalt levels estimate in-vivo wear of metal-on-metal bearings used in hip arthroplasty? [J].
Khan, M. ;
Kuiper, J. H. ;
Richardson, J. B. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H8) :929-942
[8]
Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement A CONSEQUENCE OF EXCESS WEAR [J].
Langton, D. J. ;
Jameson, S. S. ;
Joyce, T. J. ;
Hallab, N. J. ;
Natu, S. ;
Nargol, A. V. F. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (01) :38-46
[9]
Ultrasound Screening of Periarticular Soft Tissue Abnormality Around Metal-on-Metal Bearings [J].
Nishii, Takashi ;
Sakai, Takashi ;
Takao, Masaki ;
Yoshikawa, Hideki ;
Sugano, Nobuhiko .
JOURNAL OF ARTHROPLASTY, 2012, 27 (06) :895-900
[10]
The Learning Curve for Adopting Hip Resurfacing Among Hip Specialists [J].
Nunley, Ryan M. ;
Zhu, Jinjun ;
Brooks, Peter J. ;
Engh, C. Anderson, Jr. ;
Raterman, Stephen J. ;
Rogerson, John S. ;
Barrack, Robert L. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) :382-391