MRI After Arthroplasty: Comparison of MAVRIC and Conventional Fast Spin-Echo Techniques

被引:148
作者
Hayter, Catherine L. [1 ]
Koff, Matthew F. [1 ]
Shah, Parina [1 ]
Koch, Kevin M. [2 ]
Miller, Theodore T. [1 ,3 ]
Potter, Hollis G. [1 ,3 ]
机构
[1] Hosp Special Surg, Dept Radiol & Imaging, New York, NY 10021 USA
[2] GE Healthcare, Appl Sci Lab, Waukesha, WI USA
[3] Cornell Univ, Weill Cornell Med Coll, New York, NY 10021 USA
关键词
arthroplasty; artifacts; MAVRIC; MRI; osteolysis; METAL ARTIFACT REDUCTION; TOTAL HIP-ARTHROPLASTY; MAGNETIC-RESONANCE; IMPLANTS; OSTEOLYSIS; SEQUENCE;
D O I
10.2214/AJR.11.6659
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
OBJECTIVE. The goal of this study was to evaluate the quality of images obtained with a prototype imaging technique, multiacquisition variable-resonance image combination (MAVRIC), compared with fast spin-echo (FSE) images in the evaluation of patients who have undergone hip, shoulder, or knee arthroplasty. MATERIALS AND METHODS. MRI with metal-artifact reduction FSE and MAVRIC sequences was performed in the care of 122 patients who had undergone 74 hip, 27 shoulder, and 21 knee arthroplasties. The FSE and MAVRIC images were subjectively graded for visualization of the synovium, prosthesis-bone interface, and hip abductors or supraspinatus tendon. The presence of synovitis, osteolysis, or supraspinatus tendon tear was recorded. RESULTS. Visualization of the synovium was significantly better on MAVRIC images than on FSE images of the hip (p < 0.0001), shoulder (p < 0.01), and knee (p < 0.01). Synovitis was detected only on the MAVRIC images of nine subjects (12%) who had undergone hip arthroplasty and five subjects (18%) who had undergone shoulder arthroplasty. Visualization of the periprosthetic bone was significantly better on MAVRIC images of the hip (p < 0.0001), shoulder (p < 0.0001), and knee (p < 0.01). Osteolysis was detected only on the MAVRIC images of 12 subjects (16%) who had undergone hip arthroplasty, six (22%) who had undergone shoulder arthroplasty, and five (24%) who had undergone knee arthroplasty. Visualization of the supraspinatus tendon was significantly better on MAVRIC images (p < 0.0001). Supraspinatus tendon tears in 12 subjects (44%) were detected only on MAVRIC images. CONCLUSION. MAVRIC complements the information on FSE images after arthroplasty and is a useful additional sequence, particularly when there is concern about synovitis, periprosthetic osteolysis, or the presence of a supraspinatus tendon tear.
引用
收藏
页码:W405 / W411
页数:7
相关论文
共 25 条
[1]
Butts K, 1999, JMRI-J MAGN RESON IM, V9, P586, DOI 10.1002/(SICI)1522-2586(199904)9:4<586::AID-JMRI13>3.0.CO
[2]
2-X
[3]
MRI of spinal hardware: comparison of conventional T1-weighted sequence with a new metal artifact reduction sequence [J].
Chang, SD ;
Lee, MJ ;
Munk, PL ;
Janzen, DL ;
MacKay, A ;
Xiang, QS .
SKELETAL RADIOLOGY, 2001, 30 (04) :213-218
[4]
EBRAHEIM NA, 1992, CLIN ORTHOP RELAT R, P194
[5]
Internally stabilized spine: Optimal choice of frequency-encoding gradient direction during MR imaging minimizes susceptibility artifact from titanium vertebral body screws [J].
Frazzini, VI ;
Kagetsu, NJ ;
Johnson, CE ;
Destian, S .
RADIOLOGY, 1997, 204 (01) :268-272
[6]
Metal artifact reduction in musculoskeletal magnetic resonance imaging [J].
Harris, Craig A. ;
White, Lawrence M. .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2006, 37 (03) :349-+
[7]
Imaging Near Metal with a MAVRIC-SEMAC Hybrid [J].
Koch, K. M. ;
Brau, A. C. ;
Chen, W. ;
Gold, G. E. ;
Hargreaves, B. A. ;
Koff, M. ;
McKinnon, G. C. ;
Potter, H. G. ;
King, K. F. .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (01) :71-82
[8]
A Multispectral Three-Dimensional Acquisition Technique for Imaging Near Metal Implants [J].
Koch, Kevin M. ;
Lorbiecki, John. E. ;
Hinks, R. Scott ;
King, Kevin F. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) :381-390
[9]
KOFF M, 2010, MAGNETIC RESONANCE I
[10]
Quantitative assessment of an MR technique for reducing metal artifact: application to spin-echo imaging in a phantom [J].
Lee, MJ ;
Janzen, DL ;
Munk, PL ;
MacKay, A ;
Xiang, QS ;
McGowen, A .
SKELETAL RADIOLOGY, 2001, 30 (07) :398-401