Kinetic studies of affinity interactions:: Comparison of piezoelectric and resonant mirror-based biosensors

被引:31
作者
Skládal, P [1 ]
Horácek, J [1 ]
机构
[1] Masaryk Univ, Dept Biochem, CS-61137 Brno, Czech Republic
关键词
piezosensor; resonant mirror; immunosensor; antibody; kinetics;
D O I
10.1080/00032719908542912
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The developed piezoelectric quartz crystal microbalance sensor was compared with the commercial resonant mirror-based optical biosensor IAsys. The former one was based on 10 MHz crystals and flow-through arrangement, the latter employed a stirred cuvette. The same biosensing layers were produced by immobilization of 4,4'-dichlorobiphenyl on aminosilanized surfaces through an albumin bridge. The affinity binding of three corresponding polyclonal antibodies was studied and the kinetic rate constants k(a) and k(d) were determined. The same values of constants were obtained for sheep antibody, smaller values of k(a) (approx. twice) were obtained for the other two lower-affinity antibodies using the piezosensor. In the additional comparison during a competitive assay of atrazine, both transducers were able to distinguish 0 and 0.1 mu g/L atrazine, however, the IAsys signal was less noisy. For bioaffinity kinetic studies, the piezoelectric biosensor was found to be an economic alternative to the advanced optical biosensors.
引用
收藏
页码:1519 / 1529
页数:11
相关论文
共 23 条
[11]   THE QUARTZ-CRYSTAL MICROBALANCE AS BIOSENSOR - A STATUS-REPORT ON ITS FUTURE [J].
MINUNNI, M ;
MASCINI, M ;
GUILBAULT, GG ;
HOCK, B .
ANALYTICAL LETTERS, 1995, 28 (05) :749-764
[12]   Kinetic studies of sequence-specific binding of GCN4-bZIP peptides to DNA strands immobilized on a 27-MHz quartz-crystal microbalance [J].
Okahata, Y ;
Niikura, K ;
Sugiura, Y ;
Sawada, M ;
Morii, T .
BIOCHEMISTRY, 1998, 37 (16) :5666-5672
[13]   DETERMINATION OF RATE AND EQUILIBRIUM BINDING CONSTANTS FOR MACROMOLECULAR INTERACTIONS USING SURFACE-PLASMON RESONANCE - USE OF NONLINEAR LEAST-SQUARES ANALYSIS-METHODS [J].
OSHANNESSY, DJ ;
BRIGHAMBURKE, M ;
SONESON, KK ;
HENSLEY, P ;
BROOKS, I .
ANALYTICAL BIOCHEMISTRY, 1993, 212 (02) :457-468
[14]   Real-time observation of affinity reactions using grating couplers: Determination of the detection limit and calculation of kinetic rate constants [J].
Polzius, R ;
Diessel, E ;
Bier, FF ;
Bilitewski, U .
ANALYTICAL BIOCHEMISTRY, 1997, 248 (02) :269-276
[15]   Use of surface plasmon resonance to probe the equilibrium and dynamic aspects of interactions between biological macromolecules [J].
Schuck, P .
ANNUAL REVIEW OF BIOPHYSICS AND BIOMOLECULAR STRUCTURE, 1997, 26 :541-566
[16]   CHARACTERIZATION OF MONOCLONAL-ANTIBODIES TO 2,4-DICHLOROPHENOXYACETIC ACID USING A PIEZOELECTRIC QUARTZ-CRYSTAL MICROBALANCE IN SOLUTION [J].
SKLADAL, P ;
MINUNNI, M ;
MASCINI, M ;
KOLAR, V ;
FRANEK, M .
JOURNAL OF IMMUNOLOGICAL METHODS, 1994, 176 (01) :117-125
[17]  
SKLADAL P, 1999, BIOSENS BIOELECTRON, V14
[18]   Construction and characterization of the direct piezoelectric immunosensor for atrazine operating in solution [J].
Steegborn, C ;
Skladal, P .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (01) :19-27
[19]   KINETICS OF INTERFACIAL NUCLEIC-ACID HYBRIDIZATION STUDIED BY ACOUSTIC NETWORK ANALYSIS [J].
SU, HB ;
THOMPSON, M .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (3-4) :329-340
[20]   PLATINUM ANTICANCER DRUG-BINDING TO DNA DETECTED BY THICKNESS-SHEAR-MODE ACOUSTIC-WAVE SENSOR [J].
SU, HB ;
WILLIAMS, P ;
THOMPSON, M .
ANALYTICAL CHEMISTRY, 1995, 67 (05) :1010-1013